1. Product Introduction
Adopting an integrated design approach, the instrument is compact, easy to carry, and convenient for on-site use, while complying with the national environmental protection standards of the People's Republic of China“HJ637-2018”Water quality - Determination of petroleum, animal and vegetable oils - Infrared spectrophotometric method
2. Technical Principle
according toHJ637-2018Standard, water samplepH≤2Under the conditions of extraction with tetrachloroethylene, determine the oil content; After removing polar substances such as animal and vegetable oils by adsorbing the extract with magnesium silicate, determine the petroleum content. The content of oil and petroleum is determined by the wavenumber, which is2930cm-1(CH2Within the functional groupC-HThe stretching vibration of keys2960cm-1(CH3Within the functional groupC-HThe stretching vibration of keys) and3030cm-1(In the aromatic ring)C-HThe absorbance at the stretching vibration of the keyA2930、A2960andA3030Calculate based on the correction coefficient; The content of animal and vegetable oils is the difference between the content of oil and petroleum.
3. Application fields:
Determination of petroleum, animal and plant oils in industrial wastewater and domestic sewage
4. Instrument Features
1) Exclusive safety protection box, its baffleCan serve as an operational testing platform,Convenient to carry, flexible to operateConvenient for field testing.
2) Integrated optical system design, with good stability and high seismic performanceIt can work in a mobile state.
3) Long working hours, equipped with high-power lithium batteries, continuous measurement time greater than8At the same time, it is equipped with an external cable that can be connected to the car power supply for measurement, making the on-site measurement time longer.
4) adopt10Inch industrial tablet computer control, clear display, easy operation
5) Equipped with specialized analysis software, it integrates spectrum analysis, scanning, analysis, and calculation, and has a computer software copyright certificate.
6) Supports serial port, BluetoothWiFiVarious communication methods can be used to flexibly achieve local and remote instrument management and information transmission
7) One stop service, equipped with a dedicated accessory box, can achieve integrated sampling, extraction, and measurement, facilitating on-site measurement.
8) Real time automatic zero adjustment, the computer collects both the signal when the light source emits light and the signal when the light source goes off, achieving real-time automatic zero adjustment, simplifying operation and improving long-term signal stability.
9) High analysis efficiency, instrument in30The analysis and determination of a sample can be completed within seconds.
10) There are many types of applicable reagents: both carbon tetrachloride and tetrachloroethylene are suitable.
5. Technical indicators and parameter performance
Protection level:IP65
Baseline stability:Zero point real-time automatic adjustment (eliminating the impact of baseline drift)
detection limitDL≤0.04mg/L(Determination of blank solution of tetrachloroethylene11Secondary3timesSD)
Repeatability:RSD≤0.6%(30~40mg/LOil standard sample determination11time)
Accuracy error: ≤2%
Linear correlation coefficientr﹥0.999
Wave number range:3400cm-1~2400cm-1(i.e2941nm~4167nm)
Absorption range:0.0000~2.0000AU(i.e. transmittance)100~1%T)
Wave number accuracy: ±1cm-1
Wave number repeatability: ±1cm-1
Basic measurement range:0.0~800mg/L
Minimum detectable concentration:0.004mg/L(Water sample concentration)
Maximum measured concentration:640000mg/L(Water sample concentration)
Scanning speed: Full spectrum scanning,30second/Secondly;NDIR2second/time
Whole machine weight:15kg
Instrument size:490mm×370mm×210mm
Ambient temperature-5-50℃
Relative humidity:20%-95%
Host power supply power:(220±22)V、(50±1)Hz、50VA
Product Configuration
|
Product Name |
Product Model |
Product Description and Standard Packing List |
|
|
Portable infrared spectrophotometer for oil analysis |
Oil-580 |
Standard configuration: host1Desktop and tablet computers1Taiwan, power cord1Root and data cable1Root4cmcuvette2Individual, oil standard sample2Support and product qualification certificate1Copy, instruction manual1Product Warranty and Repair Form1Installation and start-up acceptance form2Confirmation Form for Project Training2Share. suitcase1One. |
|
|
accessory box |
Manual type |
Standard configuration of extraction device: |
Remarks |
|
extraction flask1000ml 1A measuring cylinder500ml 1A measuring cylinder100ml 1Cone shaped bottle100ml 2Sodium sulfate anhydrous100gMagnesium silicate100gCarbon tetrachloride200mlExtraction bottle holder1One. suitcase1One. |
standard configuration |
||
|
Automatic |
Single channel extraction host1Customized wide mouthed bottles1Glass piston valve1piece,35mlSand core funnel1piece,25mlmeasuring cup1A power adapter1A polytetrafluoroethylene bottle stopper1A support rod4One, reagent bottle2Extraction bottle holder1Individual, filter head1piece,8mmFluororubber tube5rice |
optional |
|