Compliant with standards:
★GB/T 32208-2015<Chemical Oxygen Demand(COD)Meter>
JJG975-2002<Chemical Oxygen Demand(COD)Measuring instrument>
Product Overview:
Heating the sample triggers an oxidation-reduction reaction between organic matter in the water sample and a known amount of potassium permanganate added beforehand,HC211Coulombic titration methodCODThe measuring instrument measures the amount of residual potassium permanganate through electrical titration. When starting to measure the heated sample,In the reagentFe+3Ions are reduced by electrolysis toFe+2Ions.Fe+2Ions rapidly consume excessive potassium permanganate. When the excess potassium permanganate is completely consumedFe+2Ions rapidly increase and are detected by the electrode upon titration to reach the endpoint. By measuring the amount of electricity (current) consumed until the endpoint of titration×Time), measure the excess amount of potassium permanganate, and calculate itmg/LDisplay as a unitCODValue.
Product Usage
Widely used for the determination of chemical oxygen demand in different fields such as surface water, groundwater, tap water, and drinking water.
Technical Specifications:
★l Measurement method: Acid potassium permanganate coulometric titration method
l Measurement range:0.5-40 mg/L
l Measurement gear:0.5-10mg/L、 seven point five-20mg/L、 fifteen-40mg/L
★l Accuracy:≤7.5mg/L±0.5 mg/L;>7.5mg/L≤10%
l Repeatability:0.5-7.5mg/L≤4%;7.5-25mg/L≤10%
l Measurement accuracy:0.1 mg/L
l Measurement time: ≤5minute
l Output device:LCDLCD screen, built-in printer
l Detection limit: 1mg/L
l Minimum reading:0.001mg/L
l electricity Source:AC220V
l merit Rate: ≤45W
l heavy Quantity: ≤3Kg
Instrument features:
★l Visualization of reaction process:The measurement process is clear and the endpoint is intuitive. During the measurement process, numerous parameters such as timing, potential, blank, and time signal diagrams can be clearly seen;
l Reminder function: oxidation decomposition process, potential stability, and buzzer notification function when reaching the endpoint;
★l Data storage and output: automatic data storage, built-in printer, can print data at any time, convenient and fast;
l Coulombic titration is used: the endpoint relies on electrode detection and is not affected by sample color and particulate matter;
l Simple and time-saving operation: digestion only requires5Minute, fully automatic titration;
l Easy instrument assembly: modular design,Disassembly and assembly are safe, simple, convenient, and reliable;
★l Low testing cost: matchingA、BReagents can be directly used for digestion testing, reducing the workload of operators; Less reagent usage saves detection costs;