Overview of ZW type unobstructed self-priming sewage pump products
The non clogging self-priming sewage pump is a type of pump developed by our company based on the structure and performance of ZX self-priming centrifugal pump and QW submersible sewage pump, and drawing on the advantages of similar foreign products, which integrates self-priming and sewage discharge. It can be used as a general self-priming pump for clean water without the need for a bottom valve or water injection. It can also suck up 60% of the large solid particles with an outlet diameter and 1.5 times the fiber length of the impeller diameter, including dirt, sediment, waste impurities, feces treatment, and all engineering wastewater and gelatinous liquids, completely reducing the labor intensity of human labor. Moreover, it is easy to install and use with minimal maintenance. The performance of self-priming sewage pumps has reached the international advanced level and has broad application markets and development prospects.
ZW type unobstructed self-priming sewage pump product features
1. ZW self-priming sewage pump has strong sewage discharge capacity: the special impeller anti blocking design ensures high efficiency and no blockage of the pump.
2. The self-priming sewage pump has high efficiency and energy saving: using an excellent hydraulic model, the efficiency is 3-5% higher than that of a general self-priming pump.
3. ZW self-priming sewage pump has good self-priming performance: the self-priming height is 1 meter higher than that of general self-priming pumps, and the self-priming time is shorter.
ZW type unobstructed self-priming sewage pump product usage and conditions
ZW self-priming sewage pump is suitable for industries such as chemical, petroleum, pharmaceutical, mining, papermaking, fiber, pulp, textile, food, power plants, municipal sewage engineering, public facility sewage, and river pond aquaculture.
The usage conditions of self-priming sewage pump: 1. Environmental temperature ≤ 45 ℃, medium temperature ≤ 60 ℃. 2. The pH value of the medium is 6-9 for cast iron pumps and 1-14 for stainless steel self-priming pumps. 3. The particle diameter is 60% of the diameter of the self-priming pump, and the fiber length is 5 times the diameter. 4. The total weight of impurities in the medium shall not exceed 15% of the total weight of the medium, and the specific gravity of the medium shall not exceed 1240 kilograms per cubic meter
Technical parameters of ZW type unobstructed self-priming sewage pump
Flow rate: 5-800m3/h;
Head: 12-60m;
Motor power: 2.2-55KW;
Speed: 1450-2900r/min;
Caliber: 25-300;
Medium temperature: ≤ 100 ℃;
Self suction height: 4.5-6.0m.
The significance of ZW type unobstructed self-priming sewage pump model
ZW self-priming sewage pump
For example: 50ZW15-30
50- Imported caliber (mm)
ZW self-priming sewage pump
15- Flow rate (m3/h)
30 Head (m)
P-material stainless steel
B-Explosion proof motor type
model | Traffic Q (m3/h) |
lift (m) |
Motor Power (KW) |
rotational speed (r/min) |
25ZW8-15 | 8 | 15 | 1.5 | 2900 |
32ZW10-20 | 10 | 20 | 2.2 | 2900 |
32ZW20-12 | 20 | 12 | 2.2 | 2900 |
40ZW20-12 | 20 | 12 | 2.2 | 2900 |
40ZW10-20 | 10 | 20 | 2.2 | 2900 |
40ZW15-30 | 15 | 30 | 3 | 2900 |
50ZW10-20 | 10 | 20 | 2.2 | 2900 |
50ZW20-12 | 20 | 12 | 2.2 | 2900 |
50ZW15-30 | 15 | 30 | 3 | 2900 |
65ZW30-18 | 30 | 18 | 4 | 1450 |
65ZW20-30 | 20 | 30 | 5.5 | 2900 |
65ZW15-30 | 15 | 30 | 3 | 2900 |
65ZW20-14 | 20 | 14 | 2.2 | 2900 |
65ZW25-40 | 25 | 40 | 7.5 | 2900 |
65ZW30-50 | 30 | 50 | 11 | 2900 |
80ZW40-16 | 40 | 16 | 4 | 1450 |
80ZW40-50 | 40 | 50 | 18.5 | 2900 |
80ZW65-25 | 65 | 25 | 7.5 | 2900 |
80ZW80-35 | 80 | 35 | 15 | 2900 |
80ZW50-60 | 50 | 60 | 22 | 2900 |
100ZW100-15 | 100 | 15 | 7.5 | 1450 |
100ZW80-20 | 80 | 20 | 7.5 | 1450 |
100ZW100-20 | 100 | 20 | 11 | 1450 |
100ZW100-30 | 100 | 30 | 22 | 2900 |
100ZW80-60 | 80 | 60 | 37 | 2900 |
100ZW80-80 | 80 | 80 | 45 | 2900 |
125ZW120-20 | 120 | 20 | 15 | 1450 |
125ZW200-15 | 200 | 15 | 15 | 1450 |
150ZW200-15 | 200 | 15 | 15 | 1450 |
150ZW250-25 | 250 | 25 | 45 | 2900 |
200ZW280-14 | 280 | 14 | 22 | 1450 |
200ZW300-18 | 300 | 18 | 37 | 1450 |
200ZW280-28 | 280 | 28 | 55 | 1450 |
250ZW420-20 | 420 | 20 | 55 | 1450 |
300ZW800-14 | 800 | 14 | 55 | 1450 |
Troubleshooting of ZW type unobstructed self-priming sewage pump
Fault phenomenon of self-priming sewage pump | Analysis of the causes of self-priming sewage pump failure | Troubleshooting methods for self-priming sewage pumps |
Self suction sewage pump does not produce water | No fluid storage or insufficient fluid storage in the pump body | Add enough |
Air leakage in the suction pipeline | Eliminate the phenomenon of pipeline leakage | |
Low Voltage | Adjusting voltage | |
Excessive suction or long suction line | Reduce suction or shorten the pipeline | |
Excessive mechanical seal leakage | Repair or replace | |
Insufficient water output from the self-priming sewage pump | Due to improper use, the impeller passage or suction pipe is blocked | Eliminate blockages |
Severe impeller wear | Replace the impeller | |
Insufficient power, too low speed | Adjust to rated speed | |
Excessive noise and vibration of self-priming sewage pump | Unstable footing | reinforce |
Severe bearing wear | Replace bearings | |
Pump and motor spindle have different axes | Adjust coaxiality | |
The bearing temperature of the self-priming sewage pump is too high | Lubricating grease deteriorates or becomes dry | Replace the lubricating grease |
Bearing damage | replace | |
Leakage of self-priming sewage pump | Loose connecting bolts | Fastening |
Seal wear | replace |