Jiangsu Aerospace Power Electromechanical Co., Ltd
Home>Products>Z710 DC motor
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13901428801
  • Address
    No. 88, Dazhong Road, Jishi, Jingjiang City, Jiangsu Province
Contact Now
Z710 DC motor
Z710 DC motor
Product details

Overview of Z710 DC Motor

The Z710 DC motor is a newly developed Z-series DC motor by our company, with a center height of 710 millimeters. Due to the unique structure and performance of the Z710 motor, there are certain differences compared to the Z series medium-sized DC motor.


Service conditions for Z710 DC motor

1. The motor can be installed in harsh environmental conditions, but the correct cooling method and protection level must be selected to maintain the cleanliness inside the motor.

2. The cooling air of the motor should not contain gases such as acids or alkalis that may damage the insulation and commutation performance of the motor.

3. If the motor is used in ships and humid tropical regions, as well as in working environments with salt spray, humidity, etc., a separate agreement should be reached.

The rated power of the motor refers to the condition where the altitude does not exceed 1000 meters and the ambient air temperature does not exceed 40 ℃.

The power supply for the motor can be either a static rectifier power supply or a DC generator power supply.


Z710 DC Motor Model Description


11


Structural characteristics of Z710 DC motor product

The base of this motor adopts a polygonal laminated structure, which has the advantages of small size and light weight, and is suitable for thyristor rectifier power supply. The insulation level of the motor is Class F. The motor adopts solvent-free paint vacuum pressure impregnation treatment (VPI), which makes the winding insulation have good moisture resistance, mechanical strength, and excellent thermal conductivity. The armature core is made of stacked silicon steel sheets and has good magnetic conductivity. The motor adopts rolling bearings for stable operation.


The installation type of this motor complies with GB997 and IEC34-7 "Code for Motor Structure and Installation Form"

Standard IMI001 end cap bearing, foot installation, horizontal placement, cylindrical single axis extension

IMI002 end cap bearing can be derived, with foot installation, horizontal placement, cylindrical dual axis extension

The protection level of the motor is based on GB4942.1 and IEC34-5 "Classification of Protection for Motor Enclosures" standards. The standard motor enclosure protection levels are IP22 and IP44. According to GB1993 and IEC34-6 "Motor Cooling Methods" standards, there are three types of motor cooling methods: ICI7, IC37, and ICW37A86. If users need other protection levels or cooling methods, they can negotiate separately. The standard type of cooling air for this motor is located at the drive end (non commutator end) of the motor.


Z710 DC Motor Product Performance

1. The rating of this motor is for continuous operation mode (S1).

2. The standard rated voltage of this motor is 440V, 660V, and 750V.

3. The excitation method of this motor is separate excitation. The excitation winding has four lead terminals, divided into two groups. When the two groups are connected in series, the excitation voltage is 220V, and when connected in parallel, the excitation voltage is 110V.

The actual excitation voltage of the motor should be based on the rated value of the actual excitation current of the motor.

This motor allows forced excitation; The strong excitation voltage shall not exceed 500V. During strong excitation, the excitation current may briefly exceed the rated excitation current, but after the excitation current stabilizes, it shall not exceed.

4. Overload capacity of this motor:


The first type of DC motor (Class A) can withstand short-term (one minute) overload as specified in the table below.

Percentage of base velocity Percentage of rated current
Occasionally used frequently used
100 200 175
200 160 150
Over 300 (above) 140 125


The second type of DC motor (Class B) can withstand short-term (one minute) overload as specified in the table below:

Percentage of base velocity Percentage of rated current
Occasionally used frequently used
100 200 175
200 200 160
Over 300 (above) 175 140


The second type of DC motor (Class B) can withstand the following continuous loads:

(1) Continuous operation with 115% rated power load within the rated armature voltage and rated speed range, under which the temperature rise will be higher; Other characteristics may differ from the regulations for operation under rated conditions.

(2) Within the rated armature voltage and rated speed range, after continuous operation at rated load, the temperature rise shall not exceed the specified value for two hours at 125% rated power load, and other performance may differ from the specified value under rated conditions.

*The occasional short-term overload capacity refers to the ability of a motor to withstand a continuous rated load in one minute, which rarely occurs or in emergency situations. It is recommended to set the instantaneous breaking device of the circuit breaker according to the occasional short-term overload capacity.

**The commonly used short-term overload capacity refers to the ability of a motor to repeatedly withstand loads exceeding its rated capacity as part of its normal operating cycle.

***After short-term overload operation; It must be operated with light load to ensure that the root mean square value of the load throughout the entire load cycle of the motor does not exceed its continuous rating.

For the second type of DC motor (Class B), occasional overload times are allowed to reach 2.5 times (at rated base speed), with a time not exceeding 15 seconds (but subject to consultation with our company).

5. Current change rate

At all speeds and loads, the current change rate (di/dt) of the motor is allowed to reach 200 times the rated current/s.

6. Noise and vibration

The "Method and Limits for Determination of Quinine Sound" of this motor complies with the national standard GBI0069.3.

The 'Noise Measurement Methods and Limits' of this motor comply with the national standard GBI0068.2.


Capacity selection of Z710 DC motor

The first type of DC motor (Class A):

The detailed data of this type of motor can be found in the technical data sheet, and users can select the model and specifications of the motor according to the required capacity, speed, and voltage.

The second type of DC motor (Class B):

The power, current and other technical data of this type of motor are lower than the values in the A-class technical data sheet, but the specific values need to be agreed upon by the user and the manufacturing company.

In addition to the specifications listed in the technical data, users can negotiate with the manufacturing company to derive other specifications of DC motors based on specific needs.


Technical data of Z710 DC motor


Z710-3200 is suitable for cooling methods

serial number Speed at rated voltage UN
r/min
power
KW
rated
current
A
efficiency
%
maximum
speed
r/min
Dynamic magnetic power
KW
rotation mass
KW
improve air circulation
Airflow m ³/₈ Wind pressure Kpa
440V 660V 750V
1 480

800 1963 92.6 1100 8.5 289 4.0 0.85
2 560

1000 2437 93.3 1100 10 296 4.6 1.08
3
530
1000 1621 93.4 1100 10 289 4.4 1.0
4
750
1250 2021 93.7 1200 8.4 289 5.1 1.3
5

645 1250 1775 93.9 1100 9.8 296 5.0 1.26
6
860
1500 2423 93.8 1100 8.7 296 6.0 1.75
7

845 1500 2129 93.9 1200 8.2 289 5.9 1.7


Z710-400 is suitable for cooling methods

serial number Speed at rated voltage UN
r/min
power
KW
rated
current
A
efficiency
%
maximum speed
r/min
Excitation power
KW
moment of inertia
KW
improve air circulation
Airflow m ³/₈ Wind pressure Kpa
440V 660V 750V
1 380

800 1967 92.4 1000 9.3 337 4.2 0.93
2 445

1000 2440 93.2 1000 10.9 344 4.7 1.13
3
422
1000 1624 93.3 1000 10.6 337 4.6 1.08
4
590
1250 2019 93.8 1100 8.7 337 5.1 1.3
5

515 1250 1774 93.9 1000 10.5 344 5.1 1.3
6
690
1500 2418 94 1000 9.13 344 5.9 1.7
7

680 1500 2125 94.1 1100 8.5 337 5.7 1.6


Z710-500 is suitable for cooling methods

serial number Speed at rated voltage UN
n/min
power
KW
rated
current
A
efficiency
%
maximum
speed
r/min
Excitation power
KW
moment of inertia
KW
improve air circulation
Airflow m ³/s Wind pressure Kpa
440V 660V 750V
1 305

800 1975 92.1 800 10.4 397 4.4 1.0
2 360

1000 2446 92.9 800 11 404 4.8 1.17
3
337
1000 1625 93.2 800 11.6 397 4.7 1.13
4
470
1250 2021 93.7 1000 10.1 397 5.2 1.35
5

410 1250 1777 93.8 800 11.4 404 5.2 1.35
6
550
1500 2419 94 800 10.6 404 6.0 1.75
7

530 1500 2125 94.1 1000 10.9 397 5.8 1.65


Z710-630 is suitable for cooling methods

serial number Speed at rated voltage UN
r/min
power
KW
rated current
A
efficiency
%
maximum
speed
r/min
Dynamic magnetic power
KW
Rotating rewards
KW
improve air circulation
Airflow m ³/s Wind pressure Kpa
440V 660V 750V
1 240

800 1988 91.4 700 11.9 475 4.8 1.17
2 280

1000 2458 92.5 700 13.3 482 5.3 1.4
3
268
1000 1633 92.8 700 12.7 475 5.0 1.26
4
370
1250 2027 93.4 800 11.8 475 5.5 1.49
5

325 1250 1783 93.5 700 12.7 482 5.5 1.49
6
435
1500 2425 93.7 700 12.1 482 6.3 1.92
7

430 1500 2129 93.9 800 11.1 475 6.0 1.75


Z710-800 is suitable for cooling methods

serial number
额定电压UN下的转速r/min power
KW
rated
current
A
efficiency
%
maximum speed
r/min
Excitation power
KW
moment of inertia
KW
improve air circulation
Airflow m ³/s Wind pressure Kpa
440V 660V 750V
1 185

800 2008 90.5 550 14.5 576 5.5 1.49
2 220

1000 2477 91.7 550 14.2 583 5.8 1.65
3
210
1000 1645 92.1 550 13.7 576 5.5 1.49
4
290
1250 2038 93 700 13.6 576 6.1 1.81
5

255 1250 1793 92.9 550 13.8 583 6.0 1.75
6
345
1500 2436 93.3 550 13.4 583 6.8 2.21
7

325 1500 2138 93.3 700 13.6 576 6.5 2.03


Outline drawing and installation dimension table of Z710 DC motor

duct ventilation

Half pipe ventilation


11


model Main dimensions Foot size Axis extension size Size of outlet box
HLCHD A B K HA AB BB AA BA BA' D E AD
Z710-320 71018903551415 1400 1120 56 40 1540 1610 200 475 535 250 410 1028
Z710-400 71019703551415 1400 1250 56 40 1540 1690 200 475 535 250 410 1028
Z710-500 71020703551415 1400 1250 56 40 1540 1790 200 475 535 250 410 1028
Z710-630 71022503551415 1400 1400 56 40 1540 1920 200 475 535 250 410 1028
Z710-800 71024203551415 1400 1600 56 40 1540 2090 200 475 535 250 410 1028


Equipped with backpack style and air cooler


22


model Main dimensions Foot size Axis extension size Size of outlet box Cooler size
H L C HD A B K HA AB BB AA BA BA' D E AD LA AE HV
Z710-320 710 1890 355 1415 1400 1120 56 40 1540 1610 200 475 535 250 410 1028 2390 1830 3044
Z710-400 710 1970 355 1415 1400 1250 56 40 1540 1690 200 475 535 250 410 1028 2470 1830 3044
Z710-500 710 2070 355 1415 1400 1250 56 40 1540 1790 200 475 535 250 410 1028 2500 1830 3044
Z710-630 710 2250 355 1415 1400 1400 56 40 1540 1920 200 475 535 250 410 1028 2630 1830 3044
Z710-800 710 2420 355 1415 1400 1600 56 40 1540 2090 200 475 535 250 410 1028 2800 1830 3044