Working principle
The basic principle of pipeline gas self closing valve is to magnetize permanent magnet materials according to design requirements to form a multipole permanent magnet linkage mechanism with permanent memory, identify changes in gas pressure parameters passing through it, and automatically close the valve and cut off the gas source when it exceeds or falls below the safety setting value.
Product Features
※ Small size, unrestricted installation position and direction, easy operation;
※ Automatic shutdown, manual activation, fast response speed;
Good shutdown performance, safe and reliable;
※ Non energy consuming, pollution-free, energy-saving and environmentally friendly, maintenance free;
Long service life and beautiful appearance.
Product parameters
Product Structure Diagram
Structural diagram of self closing valve in front of the table
Structural diagram of the self closing valve in front of the stove
Function Description
Overpressure shutdown
When the pressure regulating equipment malfunctions or fails, and the gas pressure in the pipeline exceeds the safe range of use, the red lifting button of the self closing valve is completely pushed out, automatically cutting off the gas supply to prevent potential accidents such as meter explosion, hose rupture or detachment due to high pressure, and stove misfiring due to high pressure. Under voltage shutdown
When the equipment is shut down for maintenance or accidentally damaged (such as cutting off pipelines), the gas supply will be automatically cut off when the gas supply pressure is too low, which can effectively prevent the "backfire" and "flame out" caused by unstable gas supply and avoid the possible gas leakage during "re supply". Overcurrent shutdown
When the rubber hose becomes loose, falls off, ages, or breaks, causing a large amount of gas leakage, the self closing valve will automatically cut off the gas supply to prevent gas accidents. Leak prevention testing
The specific method is to close the household ball valve and stove, observe for at least five minutes. If there is no leakage, the self closing valve will still remain open. However, if it is found to automatically close, it indicates that there is a leakage point in the pipeline. Apply concentrated soapy water to each connection and check for bubbles. If a leakage point is found, it should be reported for repair in a timely manner.
ordering instructions
Please provide the following parameters for product ordering:
1. Medium used: such as natural gas/artificial gas, etc
2. Installation location: such as in front of the stove/gas meter
3. Inlet connection size: such as DN15 internal thread/external thread, etc
4. Export connection size: such as 9.5mm rubber hose joint/DN15 internal thread/external thread, etc
5. Is the export equipped with switch valves: integrated switch valve/split switch valve/no switch valve
6. Other information.