VIP member
YYWB rail type temperature transmitter
Output signal: Analog 4-20mA Supply voltage: U=7.5V~45V Load: Max. (V power supply -7.5V)/0.0208A (current output) Alarm current: Below the measuremen
Product details
|
Output signal: Analog 4-20mA
Supply voltage: U=7.5V~45V Load: Max. (V power supply -7.5V)/0.0208A (current output) Alarm current: Below the measurement upper limit, the output drops to 3.8mA Above the measurement limit, the output rises to 20.8mA Sensor damage; Sensor open circuit (excluding thermocouple TC), output is 3.8mA Input current: ≤ 3.8mA Current limit: ≤ 20.8mA Environmental temperature: -40 to+85 ℃ Storage temperature: -40 to+100 ℃ Protection level: IP00, IP66 (installation) Cold end compensation: Built in cold end compensation Operation method: Adjust online through PC programming or manual controller Accuracy level: ≤ 0.2K or 0.08% Electrical isolation: 2KV Measurement variables: temperature (temperature linear transfer), resistance, and voltage Measurement range: The variation of the transmitter's measurement range depends on the sensor connection mode and input signal Voltage influence: negligible Environmental temperature impact: negligible (temperature drift) Condensation: allowed Seismic resistance: 4g/2-150Hz Installation angle: unlimited |
Online inquiry
