Wireless High Voltage Ratio Tester
Function: Current, transformation ratio, polarity, phase, online testing of primary and secondary circuits of high and low voltage current transformer
Product details
The ES1010 wireless high voltage ratio tester, also known as the high and low voltage CT wireless ratio tester, consists of a high voltage detector, low voltage current clamp, host, high voltage insulation rod, monitoring software, communication line, etc. The instrument adopts fast digital circuit processing technology internally, which can measure the primary, primary, and secondary currents of high-voltage current transformers and transformers below 60kV by connecting insulation rods without disconnecting wires or disconnecting power on site. It can also calculate the transformation ratio, phase, polarity, and transformation ratio error.
When not using insulating rods, it can also be used as a high-precision low-voltage clamp ammeter and leakage ammeter, which has the characteristics of simple use and easy portability Its wireless transmission function can receive the tested data within 30 meters in a straight line, ensuring high precision, reliability, and stability for uninterrupted testing all year round. The host adopts a large screen LCD display, which has the characteristics of small size, light weight, and easy portability, and can store 500 sets of data.
The measurement range for high voltage current is 0.0mA to 1200A, and the measurement range for low voltage current is 0.0mA to 20A. The current signal of the high-voltage detector adopts wireless transmission technology and is connected to a retractable insulation rod. By pushing or pulling the insulation rod forward, it is easy to clamp or withdraw the tested wire, saving time and speed It can be widely used in substations, power plants, industrial and mining enterprises, as well as testing stations and electrical maintenance departments for current detection and field electrical operations. Insulated rods have the characteristics of lightweight, moisture-proof, high temperature resistance, impact resistance, bending resistance, high insulation and stretchability.
When not using insulating rods, it can also be used as a high-precision low-voltage clamp ammeter and leakage ammeter, which has the characteristics of simple use and easy portability Its wireless transmission function can receive the tested data within 30 meters in a straight line, ensuring high precision, reliability, and stability for uninterrupted testing all year round. The host adopts a large screen LCD display, which has the characteristics of small size, light weight, and easy portability, and can store 500 sets of data.
The measurement range for high voltage current is 0.0mA to 1200A, and the measurement range for low voltage current is 0.0mA to 20A. The current signal of the high-voltage detector adopts wireless transmission technology and is connected to a retractable insulation rod. By pushing or pulling the insulation rod forward, it is easy to clamp or withdraw the tested wire, saving time and speed It can be widely used in substations, power plants, industrial and mining enterprises, as well as testing stations and electrical maintenance departments for current detection and field electrical operations. Insulated rods have the characteristics of lightweight, moisture-proof, high temperature resistance, impact resistance, bending resistance, high insulation and stretchability.
Model number | ES1010 | |
measuretryinstrument | High voltage detector | Host (current clamp) |
Range | 0.0mA~1200A (50/60Hz automatic) | 0.0mA~20A |
dividedistinguishrate | 0.1mA | 0.1mA |
Jaw size | φ50mm | φ8mm |
precision | ±2%±5dgt | ±0.5%±5dgt |
Sample Rate | 2 times per second | |
workCan | Current, transformation ratio, polarity, phase, and online testing of primary and secondary circuits of high and low voltage current transformers; Online testing of current magnitude and transformation ratio on both sides of the transformer; Load current test | |
transport type | Wireless transmission, straight transmission distance of 30m | |
Shift gears | Fully automatic gear shifting | |
Power supply | DC6V No.7 alkaline battery (1.5V AAA × 4) | DC7.5V No.5 alkaline battery (1.5V LR6 × 5) |
testing mode | Clamp CT | |
External dimensions | Width, thickness and height 87 * 37 * 262mm | Host: Width, Width, Height 100 * 35 * 204mm |
Current clamp: width, thickness and height 42 * 20 * 137mm | ||
display mode | LCD: 128 dots x 64 dots blue screen backlight function, suitable for dim places | |
LCDchicun | 62mm×44mm | |
Transformation ratio | Three types of transformation ratio display: (measured current transformation ratio in the primary and secondary circuits; converted transformation ratio based on 5A in the secondary circuit; Conversion ratio of transformer 10kV/380V to 10kV-YY, with a maximum ratio of 1:1 million (1.0K7) | |
line voltage | Testing of insulated circuits below 60kV or bare wire current testing below 35kV (must be operated with insulation rods) | |
Lead length | Current clamp lead wire 2 meters | |
Quality | Total weight of instrument: 7Kg (including insulation rod and instrument package) | |
High voltage detector: 370g (including battery) | ||
Host: 409g (including battery) | ||
Current clamp: 180g | ||
data interface | USB TRANSFER | |
Overflow display | Overscale overflow function: "OL A" symbol display | |
Data Storage | 500 groups, according toHOLDKey holds data,MRSymbol display, press againHOLDKey Cancel Keep | |
Data retrieval | Long pressHOLDThe key can enter the data lookup mode | |
Full data storage | Data full function: "FULL" symbol display | |
No signal indication | When the host does not receive the transmission signal, it prompts "NO SIGNAL-----” | |
Automatic shutdown | After about 15 minutes of startup, the instrument panel will automatically shut down | |
battery voltage | When the battery voltage drops to 4.8V, the low battery indicator light will turn on, reminding to replace the battery | When the battery voltage drops to 5.2V, the low battery voltage symbol is displayed, reminding to replace the battery |
cut offreasonpole | Five section extendable insulation rod (5 meters) | |
Dielectric Strength | AC 60kV/rms | |
Line testing | Testing of insulated outer wires for line voltage below 60kV, and testing of bare wires below 60kV (with insulated rod operation) | |
operation temperature | -10℃~40℃ | |
Storage temperature | -10℃~60℃ | |
relative humidity | 0℃~31℃≦75%,31℃~40℃≦50% | |
Suitable for safety regulations | IEC1010-1、IEC1010-2-032、 Pollution level 2, CAT III (600V) IEC61326 (EMC standard) |