Product features:
1. Detachable plate structure with high strength and large workspace volume;
2. The temperature and humidity controller uses a large screen true color LCD touch screen and high-performance PLC, with a high degree of automation and a friendly human-machine interface;
3. The refrigeration compressor and key components are imported from internationally renowned brands, with safe and reliable operation, environmentally friendly refrigerant, and in compliance with international environmental protection conventions;
4. Optional RS232/485 communication interface, recording printer, remote control system.
Main technical parameters:
PRODUCT MODEL | LT(B)-W12 | LT(B)-W16 | LT(B)-W20 |
Studio size (mm) | W2000 × H2000 × D3000 | W2000 × H2000 × D4000 | W2000 × H2000 × D5000 |
Dimensions (mm) | W2260 × H2360 × D4500 | W2200 × H2300 × D5500 | W2200 × H2280 × D6500 |
temperature range | -65 ℃︿ +150 ℃ | -40 ℃︿ +130 ℃ | -20 ℃︿ +100 ℃ |
Volatility/Uniformity | ± 0.5 ℃ , ≤± 2.0 ℃ | ± 0.5 ℃ , ≤± 2.5 ℃ | ± 0.5 ℃ , ≤± 3 .0 ℃ |
Temperature deviation | ± 2.0 ℃ | ± 2.0 ℃ | ± 2.0 ℃ |
heating rate | RT ≤ 150 ℃ ≤ 70min (average throughout the entire process, measured without load) | RT ≤ 50min at 100 ℃ (average throughout the entire process, measured without load) | 0 ℃ ^+85 ℃ ≤ 40min (average throughout the entire process, measured under no-load conditions) |
cooling rate | 25 ℃~-65 ℃ for about 60 minutes (average throughout the entire process, measured without load) | 85 ℃~-40 ℃ for about 80 minutes (average throughout the entire process, measured without load) | 85 ℃~-20 ℃ for about 70 minutes (average throughout the entire process, measured without load) |
refrigeration system | Imported brand compressor unit, using water circulation cooling method | ||
temperature controller | Imported TEMP880 touch screen programmable temperature control instruments from South Korea's Sanyuan, Siemens, or Japan's OYO | ||
Thermal insulation material | Ultra fine glass fiber cotton+polyurethane foam | ||
Safety protection | Leakage, short circuit, overheating, water shortage, motor overheating, compressor overpressure, overload, overcurrent protection/controller power-off memory function | ||
supply voltage | Three phase four wire+protective earth wire, 380V ± 38V, 50Hz | ||
power | About 50KW | About 40KW | About 35KW |
pour ®: 1. The above data were measured under ambient temperature (QT) of 25 ℃ and relative humidity of ≤ 85% R.H, with no load in the workshop;
2. The above models are our company's common products. If there are special requirements, we will tailor them for you within the volume range of 6m ³~200m ³!
Optional: Korean ternary TEMP 880 PLC imported color LCD programmable temperature controller
Test standard:
GJB150.3-1986 High temperature test method
GJB150.4-1986 Low temperature test method
GJB150.6-1986 Damp Heat Test Method
GB 10586- Technical Conditions for Damp Heat Test Chamber
GB 10589- Technical Conditions for Low Temperature Test Chamber
GB 10592- Technical Conditions for High and Low Temperature Test Chambers
GB 11158- Technical conditions for high temperature test chambers
GB/2423.1-2001 Test A: Low temperature test method
GB/2423.2-2001 Test B: High temperature test method
GB/2423.3-1993 Test Ca: Constant Damp Heat Test Method
GB/T5170.2- Calibration methods for temperature testing equipment
GB/T5170.5- Calibration method for thermal testing equipment
GB/T5170.18- Calibration Method for Temperature/Humidity Combined Cycle Test Equipment
Physical picture of temperature and humidity controller
Temperature and humidity control range: