air temperature Principle: NTC Range: -50... 60 ° C Accuracy: ± 0.2 ° C (-20 ° C...+50 ° C), other ± 0.5 ° C (>-30 ° C) relative humidity Principle: Capacitor Range: 0... 100% RH Accuracy: ± 2% RH Total radiation Response time (95%):<18s Annual instability:<1% Nonlinear (0 to 1000W/m ²):<1% Directional error (1000W/m ² at 80 °)<20W/m ² Sensitivity related to temperature:<5% (-10...+40 ° C) Tilt error (at 1000W/m ²):<1% Spectral range: 300... 2800nm Range: 1400W/m ² Vertical angle: 0... 60 ° Azimuth angle: -10 °...+10 ° air pressure Principle: MEMS capacitor Range: 300... 1200hPa Accuracy: ± 0.5 hPa (0...+40 ° C) wind direction Principle: Ultrasonic waves Range: 0... 359.9 ° Accuracy:<3 °, RMSE>1.0m/s wind speed Principle: Ultrasonic waves Range: 0... 90m/s Accuracy: ± 0.2m/s or ± 2% RMS, take the maximum value (0... 65m/s), the rest ± 5% Technical Parameter Specifications and dimensions: approximately Ø 150mm, height 392mm Weight: Approximately 1.5kg Heating: 20VA 24VDC Protection level: IP66 Digital communication interface: RS485, 2-wire, half duplex Power consumption: 4... 32VDC Working humidity: 0... 100% Working temperature: -50... 60 ° C attachment Surge protector Power supply 24V/4A UMB Communication Interface Converter ISOCON-UMB Digital to Analog Signal Converter DACON8-UMB Surface temperature sensor WT1 Road surface temperature sensor WST1 20m cable (standard 10m, please select this option if 20m is required) Rain bucket WTB100 origin Lufft Germany |
![]() |