temperature Principle: NTC Negative Temperature Coefficient Thermistor Measurement range: -50... 60 ° C Accuracy: ± 0.2 ° C (-20... 50 ° C), others: ± 0.5 ° C (>-30 ° C) relative humidity Principle: Capacitive Measurement range: 0... 100% RH Accuracy: ± 2% RH radiation Response time (95%): 18 seconds Annual instability: ± 1% Nonlinear (0 to 1000 W/m2): ± 1% Directional error (1000 W/m2 at 80 °): ± 20 W/m2 Sensitivity related to temperature: ± 5% (-10...+40 ° C) Tilt error (at 1000 W/m2): ± 1% Spectral range (output attenuation less than 50%): 300 .. 2,800 nm Measurement range: 0... 1400 W/m2 air pressure Principle: MEMS capacitive Measurement range: 300... 1200 hPa Accuracy: ± 0.5 hPa (0...+40 ° C) wind direction Principle: Ultrasonic waves Measurement range: 0-359.9 ° Accuracy: Root mean square error<3 ° (>1.0 m/s) wind speed Principle: Ultrasonic waves Measurement range: 0... 75 m/s Unit: m/s; km/h; mph; kts Accuracy: Measurement value ± 0.3 m/s, or 3% of the maximum value (0~35 m/s), 5% (>35m/s) Technical Parameter Protection level: IP66 Specification: Diameter 150mm, Height 332mm Weight: 1.5Kg Interface: RS485, dual wire connection, half duplex Power supply: 24VDC, ± 10% (without heating) Working temperature: -50... 60 ° C Working humidity: 0... 100% RH Heating power: 20VA @ 24VDC accessory Surge protective device Power supply 24V/4A UMB interface converter ISOCON Digital to Analog Converter DACON8-UMB Temperature sensor WT1 Road surface temperature sensor WST1 Rain sensor WTB100 Connecting wire 20m origin Lufft Germany |
![]() |