WRB-130B Double Platinum Rhodium Thermocouple
Description: WRB-130B Double Platinum Rhodium Thermocouple: Sales Network:
Product details

Pressure gauge series
Recommended products from Kangtai Instrument Cable Factory in Tianchang City

Thermistor series
Tianchang Kangtai Instrument Cable Factory
Product recommendation

Bimetallic thermometer series
Tianchang Kangtai Instrument Cable Factory
Product recommendation

WRB-130B Double Platinum Rhodium Thermocouple

The thermocouple has a very small thermoelectric potential at room temperature (-2 μ V at 25 ℃ and 3 μ V at 50 ℃), so compensation wires are generally not needed during measurement, and the influence of temperature changes at the reference end can be ignored. Its long-term usage temperature is 1600 ℃, and its short-term usage temperature is 1800 ℃. The melting point of platinum rhodium 6 alloy is 1820 ℃, which limits its upper temperature limit for use. The electromotive force rate of the dual platinum rhodium thermocouple is relatively small, therefore, a display instrument with high sensitivity is required.

B-type thermocouples are suitable for use in oxidizing or neutral atmospheres, and can also be used for short-term use in vacuum environments. Even when used in reducing atmospheres, their lifespan is 10-20 times that of R and S-type thermocouples. Due to the phenomenon of platinum rhodium diffusion from the positive electrode to the negative electrode of R and S type thermocouples at high temperatures, the thermocouples will deteriorate. In order to prevent this phenomenon from occurring, rhodium is added to platinum to make a platinum rhodium alloy. This not only improves the heat resistance, but also increases the alloy's thermal electromotive force on platinum. When the rhodium content is below 20%, the thermoelectric potential of platinum rhodium alloy on platinum increases sharply, but beyond this value, there is little change with the increase of rhodium content, and it significantly hardens, making processing difficult. Therefore, the rhodium content in this type of alloy cannot exceed 40% by weight.

The grain length of platinum rhodium alloy tends to be smaller than that of pure platinum, and decreases with the increase of rhodium content, which can make the thermoelectric performance more stable and the mechanical strength higher. Therefore, dual platinum rhodium thermocouples have been widely used in high-temperature measurements at 1800 ℃. The division mark of the dual platinum rhodium thermocouple used to be LL-2, but now it is B

WRR-130/WRB-130B type platinum rhodium 30 platinum rhodium 6 double platinum rhodium thermocouple composition

WRR-130/WRB-130B platinum rhodium 30 platinum rhodium 6 double platinum rhodium thermocouple has no special requirements, and the thermocouple protective sleeve is a 16mm diameter corundum tube.
Special sleeves include: high-temperature resistant alloy tubes, wear-resistant alloy tubes, silicon carbide tubes, silicon nitride tubes, etc.
The thermocouple core is made of national standard wire, with high accuracy, long service life, and a measurement range of 0-1800 ° C.

WRR-130/WRB-130B Platinum Rhodium 30 Platinum Rhodium 6 Double Platinum Rhodium Thermocouple Application Scenarios

Platinum rhodium thermocoupleSuitable for high-temperature applications in various production processes, widely used for temperature measurement in powder metallurgy, sintering bright furnaces, vacuum furnaces, smelting furnaces, glass, steelmaking furnaces, ceramic and industrial salt bath furnaces, etc.

B-type thermocouple (platinum rhodium thermocouple)

WRR-130/WRB-130B Platinum Rhodium 30 Platinum Rhodium 6 Double Platinum Rhodium Thermocouple
consist of

Platinum rhodium is a traditional temperature measuring element with stable thermoelectric properties and strong oxidation resistance. Its long-term use temperature is 1600 ℃ and short-term use temperature is 1800 ℃. The platinum rhodium thermocouple adopts a double-layer 99 corundum protective sleeve on the outside and high-purity platinum rhodium alloy wire on the inside, which has high temperature resistance, accurate temperature measurement, and high precision.Customizable special protective tubeTo meet practical usage requirements.

Model and specifications

Model Dividing number Temperature measurement range ℃ defendProtective tube material thermal response time Specifications
d L x l
WRP-130WRP2-130 S 0-1300 High alumina <150S Φ16

300x150

350x200

400x250

450x300

550x400

650x500

900x750

1150x1000

1650x1500

2150x2000

WRP-131WRP2-131 <360S Φ25
WRQ-130WRQ2-130 R 0-1300 <150S Φ16
WRQ-131WRQ2-131 <360S Φ25
WRR-130WRR2-130 B 0-1600 corundum tube <150S Φ16
WRR-131WRR2-131 <360S Φ25

1) Thermocouple Level I ordered according to the agreement;

2) The non embedded part is made of carbon steel.

Our company produces platinum rhodium thermocouples, SPlatinum rhodium thermocouple,BPlatinum rhodium thermocouple,WRP-130Thermocouple,BType thermocouple, single platinum rhodium thermocouple,WRR-BPlatinum rhodium thermocouple, dual platinum rhodium thermocouple,SDividing thermocouple,KType thermocouple,SType thermocouple, explosion-proof thermocouple, anti-corrosion thermocouple, armored thermocouple, thermocouple thermometer, assembled thermocouple,BDividing thermocouple

More ProductsThis product * Sales:

Sales Specialist: Li
Sales website: www.ktybdl.. net :

Tianchang Kangtai Instrument Cable FactoryAdhering to the principle of "integrity-based, customer-oriented, and quality-oriented", we will continue to forge ahead, strive for excellence, and showcase our new strength and beautiful style today and in the future.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!