1、 Applicable places
The discharge of sewage from hospitals and hotels, the discharge of severely polluted wastewater from market engineering construction sites, factories and commercial areas, sewage discharge stations in residential areas, urban sewage treatment plant drainage systems, domestic sewage, urban sewage treatment plant drainage systems, civil air defense system drainage stations, water supply from water plants, and irrigation of farmland.
2、 Product Overview:
1. Adopting a large channel anti clogging hydraulic component design greatly improves the ability of pollutants to pass through, effectively passing through 5 times the fiber material of the pump diameter and solid particles with a diameter of about 50% of the pump diameter.
2. Reasonable design, reasonable matching motor, high efficiency, significant energy-saving effect.
3. The mechanical seal adopts a dual channel series seal, made of hard and wear-resistant tungsten carbide, which has the characteristics of durability and wear resistance, and can ensure the safe and continuous operation of the pump for more than 800 hours.
4. The pump structure is compact, small in size, easy to move, and easy to install, without the need to build a pump room. It can work underwater, greatly reducing project costs.
5. There is an oil-water probe installed in the pump oil chamber. When the mechanical seal on the pump side is damaged and water enters the oil chamber, the probe generates a signal to protect the pump.
6. A fully automatic safety protection control cabinet can be equipped according to user needs to monitor pump leakage, electric leakage, overload, and overheating, ensuring reliable and safe pump operation.
If you have any questions, you can call: 021-57239999 orClick to consult experts for selection and quotation
3、 Type spectrum:

User feedback:
If you have any questions, you can call: 021-57239999 orClick to consult experts for selection and quotation
6、 Installation, operation, and maintenance prompts
It is strictly prohibited to forcefully pull the cable when installing and transporting the electric pump, in order to avoid causing internal cable breakage, joint bonding, etc., which may cause the pump to malfunction or even burn out the motor.
Please use the electric pump cable grounding wire for correct and reliable grounding during installation. When the electric pump is working, it is strictly prohibited for people or animals to approach the working water area or touch the electric pump. In order to reduce electrical risks, it can only be connected to an appropriate grounding socket.
Overloading operation is strictly prohibited
The cable used with the pump must not be less than 1.2 times the cable area of the electric pump.
During installation, the electric pump must be securely fastened, but the cable must not be subjected to force or rotate together with the start and stop of the electric pump.
When the pump fails to discharge water during operation, it should be checked whether the electric pump is reversing or if the air inside the check valve at the outlet of the electric pump has not been completely discharged.
Regularly check the insulation resistance between phases and relative ground of the electric pump motor, which should not be less than 2MQ. Otherwise, it should be disassembled for maintenance.
After six months of normal operation under specified working conditions, the sealing condition of the oil chamber of the electric pump should be checked. If the oil in the oil chamber is emulsified or water precipitates out, the 10 # engine oil and mechanical seals should be replaced in a timely manner.
After one year of normal operation of the electric pump, a major overhaul should be carried out to replace worn and vulnerable parts, check the condition of fasteners, and replenish and replace lubricating grease to ensure good lubrication of the electric pump during operation.
If the electric pump is not in use, please clean it thoroughly and wipe off any water droplets to prevent rusting.
If you have any questions, you can call: 021-57239999 orClick to consult experts for selection and quotation
7、 Troubleshooting analysis
|
Fault phenomenon |
Root cause analysis |
exclusion method |
|
Insufficient flow or no water output |
1Wrong rotation direction of impeller
2Is the outlet valve open and intact
3There is air in the pipeline between the valve and the pump that has not been discharged, causing the valve to fail to open
4The speed is too low
5Excessive wear of the sealing ring
6The density or viscosity of the liquid being pumped is high
7Pipeline and impeller blockage
|
1 Simply swap the phase sequence of any two power cords
2 Check the valve
3 Exhaust air from the pipeline
4 Check if the power supply voltage is too low
5 replace
6 Change the density and viscosity of the liquid being pumped
7 Clean up blockages in pipelines and impellers
|
|
Unstable operation of electric pump |
1Unbalanced impeller
2Bearing damage
3Overload operation
4Installation tilt is not correct
|
1Replace or perform impeller dynamic balancing
2replace
3Adjust the valve to prevent overload of the electric pump
4reinstall
|
|
Low insulation resistance |
1Leakage at the terminal of the cable power line
2Cable damage or water ingress from the head
3Mechanical seal wear
4OType seal ring aging and failure |
1Tighten the compression nut
2replace
3replace
4replace
|
|
excessive current |
1Low working voltage
2The impeller is blocked or stuck
3The sealing of the liquid being pumped is relatively large or the viscosity is high
4The valve is too wide open
|
1Adjust the working voltage
2Clean up blockages in pipelines and liquids
3Change the density and viscosity of the liquid being pumped
4Adjust the valve opening
|
If you have any questions, you can call: 021-57239999 orClick to consult experts for selection and quotation
8、 Performance parameter table