Fujian Shangrun Precision Instrument Co., Ltd
Home>Products>WP-9000 series passive thermocouple temperature transmitter (output loop power supply)
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 16 Xingye West Road, Mawei High tech Park, Fuzhou, China
Contact Now
WP-9000 series passive thermocouple temperature transmitter (output loop power supply)
WP-9000 series passive thermocouple temperature transmitter (output loop power supply) isolates and converts the on-site two-wire thermocouple signal
Product details

WP-9000 series passive thermocouple temperature transmitter (output loop power supply) isolates and converts the on-site two-wire thermocouple signal into the required DC signal (linear with temperature) for output. Mainly used for DCS and PLC systems with input circuit power supply.


This temperature transmitter is powered by a loop, with complete electromagnetic isolation between the input and output circuits.


◆ Characteristics

● Isolation conversion of signal input for various types of thermocouples (or millivolts) in a two-wire system.

An isolated output (4-20) mA linearized with temperature.

● Equipped with automatic cold end compensation function.

● Circuit power supply (12-28) VDC.

● Plug and unplug terminal block, DIN rail card installation.

● Working power supply

Output circuit power supply: (12-28) VDC


● Input signal

Input channel: Terminal 1-, 2+wiring

Input type: thermocouple K, E, S, B, R, T, N, W, millivolt signal

Input resistance: ≥ 20K Ω

Cold end temperature compensation range: (-15~+75) ℃

Cold end temperature compensation error: ± 1 ℃ for every 20 ℃ change


● Output signal

Output channel: Terminal 11-, 12+wiring

Output current (Io): (4-20) mA

Output circuit power supply voltage (Ue): (12-28) VDC

Minimum operating voltage (Ui): 12VDC

Output load capacity: see the following calculation diagram

Output load resistance: RL ≤ (Ue Ui)/0.02

Thermocouple input disconnection alarm: low current ≤ 3.5mA; high current ≥ 22mA

Ripple (Vp-p): < 10mV


● Performance indicators

Standard accuracy: ± 0.5% FS

Temperature drift: ± 0.015%/℃

Response time: ≤ 1s (10 → 90)%

Stability time: ≤ 3s

Insulation resistance: ≥ 100M Ω/500VDC (AC)

Isolation capability: 1500VAC/1 minute 50Hz

Electromagnetic compatibility: Complies with relevant electromagnetic standards of IEC 61000


● Environmental parameters

Working temperature: (-20~+60) ℃

Storage temperature: (-40~+80) ℃

Environmental humidity: (5~+95)% RH (without condensation)


● Structure

Card mounted type; Modular watch core; ABS material casing; Plug in terminal

Whole machine weight: approximately 110g


◆ External dimensions

Dimensions: Width x Height x Depth=16 x 116 x 110 (mm)