WNK6T high-precision temperature transmitter
WNK6T high-precision temperature transmitter
Product details



The WNK6T intelligent temperature transmitter is a high-performance product in the temperature series instruments of Anhui Wanke Company. It converts signals from thermal resistors, resistive sensors, thermocouples, or voltage sensors into standard signals.

The transmitter adopts dedicated integrated circuit digital technology to achieve good accuracy and signal consistency. Each transmitter undergoes ambient temperature characterization at the factory to ensure high accuracy and minimal drift over a wide range of operating temperatures.

The transmitter is easy to install on site and can be integrated with temperature sensor components or installed away from the sensor. The sturdy casing comes with a globally compatible conduit connection port, and the dual chamber aluminum casing ensures the use of the transmitter in hazardous areas.



·Numerical accuracy: ±0.01℃,Pt100Thermal resistance input

· 24Position model-The digital converter is equipped with environmental temperature compensation and has outstanding measurement performance throughout the entire working range

·Transmitter-The matching characteristics of the sensor are easy to use, which can reduce the interchangeability error of the thermistor sensor and improve the measurement accuracy75%

·The dual chamber structure shell ensures excellent reliability of the transmitter in high temperature, corrosive, and RF interference environments

·Integrated transient protector to prevent damage to the transmitter caused by transient currents introduced by the circuit

·Thermal resistance electromotive force correction - detecting and eliminating electromotive force errors. This error is caused by a small voltage signal generated during thermal resistance measurement

·Independent parallel alarm circuit, which can provide an independent and backup alarm output in case of circuit board or software failure

·Self calibration: By comparing dynamic measurements with highly stable and accurate internal benchmarks, the analog-to-digital conversion circuit automatically updates each temperaturePerform self calibration



·The factory sets the output mode according to user requirements, making installation convenient

·Integrated LCD meter head

·Special sensor input capability allows users to input special sensor parameters into the transmitter and adjust the temperature curve inside the transmitter

·HARTProtocol type transmitters can be used withHARTHandheld device,AMSEquipment management system or adoptionHARTProtocol based system for digital communication

·PROFIBUS-PABus protocol transmitters can be used withPDMFDTAMSDevice management system for communication and device management

·FFBus protocol transmitters can be used withFDTAMSDevice management system for communication and device management



·Ready to use - provides a complete set of temperature measurement components, including transmitters, sensors, extensions, and thermal sleeves, all of which have been calibrated and connected at the factoryOnce the wiring and configuration are complete, it can be directly installed and used during the process



1. Input

1.1 Thermal resistance

Measured variable temperature

Range of measurement According to the type of sensor connected(Specify the range of the sensor)

sensor type have4Optional gear range

·PT100

·PT1000

·CU50

·CU100

voltage measurement temperature-linear

Sensor current 0.3mA

1.2 Resistance sensor

Measured variable Ohmic impedance

Range of measurement have4Optional gear range

·0...100ohm

·0...260ohm

·0...390ohm

·0...3900ohm

sensor type Linear resistance sensor,2、 Three or four wire system

voltage measurement resistance-linear

Sensor current 0.3mA

1.3 Thermocouple

Measured variable temperature

Range of measurement According to the type of sensor connected(Specify the range of the sensor)

sensor type thermocouple

·StypePt10Rh-Pt(DIN IEC 584)

·RtypePt13Rh-Pt(DIN IEC 584)

·BtypePt30Rh-Pt6Rh(DIN IEC 584)

·KtypeNiCr-Ni(DIN IEC 584)

·NtypeNiCrSi-NiSi(BS 4937 Part 2)

·EtypeNiCr-CuNi(DIN IEC 584)

·JtypeFe-CuNi(DIN IEC 584)

·TtypeFe-CuNi(DIN 43710)

voltage measurement temperature-linear

Cold Junction Compensation specification

·No compensation(Dual channel)

·Internal acquisition,Equipped with built-in or external sensors:When using external sensors, the manufacturer's specifications must be setPAparameter(Default is built-in sensor)

·The externally specified cold end temperature can be set to a fixed value

1.4 millivolt sensor

Measured variable DC Voltage

Range of measurement have4Optional gear range

·-20...20mV

·-50...50mV

·-75...75mV

·-750...750mV

sensor type linearmVsensor

voltage measurement voltage-linear

Input Resistance 1MΩ

Sensor current 180μA



2. Output

output signal 4~20mA/ HARTOr digital bus signal

bus voltage · 932V(withoutExprotect)

· 924VIntrinsically Safe(seeExcertificate)

Effective internal inductanceLi10mH

Effective internal capacitanceCi5nF

communication

·PAcommunication auxiliary word for ordinal numbers12Layer by layerPROFIBUS-PA,Transmission TechnologyIEC1158-2;Passive function;auxiliary word for ordinal numbers7storey(protocol layer)pressPROFIBUS- DP,EN50170standard,With extensionPROFIBUSfunction(All data is non periodic,The measured values and status are periodic)

·FFcommunicationH1Bus technology,Transmission TechnologyIEC61158-2

·Equipment stylePROFIBUS-PApatternB,guild regulations3.01

·Equipment address126(Set during shipment)

temperature unit ℃ can be parameterized



3. Measurement accuracy

impact

·Internal cold end compensation error 0.25℃±0.1%/10

·Temperature drift ±0.05%/10Full scale range in ℃, 0.1%exist-10give60Between ℃

·The impact of power supply on measurement range 0.005%/Vfull-scale range

·Long term drift 0.1/year


4. Rated conditions

permissive temperature

·Environmental temperature

-

T4 -40...85℃-Intrinsic safety operation(T6) -40...60

·Storage temperature-40...95

relative humidity98%,

Allow condensation electromagnetic compatibilityconform to





EN 61

three hundred and twenty-six 5. Power supply9supply voltageBus feed in45V(924V,Ex

type)

Bus devices consume current 13.5mA