VIP member
Product details
Indicator Name
|
Indicator requirements |
output power |
1W/2W/3W/5W/10W/16W |
gain |
50±1dB |
Working frequency range |
1920-1980MHz/2110-2170MHz |
In-band flatness |
≤±1dB |
ACPR |
≤ -45dBc@Fc ±5MHz |
≤ -60dBc@Fc ±10MHz |
|
figure |
≤8dB |
Input/output voltage standing wave ratio |
≤1.5 |
Out-of-band spurious |
≤-36dBm |
Supply Voltage |
27V |
electric current |
≤1.2A/≤1.5A/≤1.8A/≤2.5/≤3.5/≤4/≤6.5 |
Input/output connector |
SMA |
operation temperature |
-25℃-+60℃ |
volume |
200*80*28mm |
Monitoring connection connector |
D-sub15 |
Online inquiry