Dongguan Weibang Instrument Equipment Co., Ltd
Home>Products>WBE-LR2W-512L Cold and Hot Shock Test Chamber
WBE-LR2W-512L Cold and Hot Shock Test Chamber
Used to test the degree to which various materials can withstand continuous environments of extremely high and low temperatures in an instant, enablin
Product details
product details

产品详情

第二屏

Product Features

New servo flow control technology

1. Energy saving of about 30%;

2. The evaporator is not prone to frosting;

3. Linear models are more convenient to implement;

4. Better control of temperature uniformity;

5. The compressor is less prone to frosting and has a longer lifespan;

6. Non standard design is more convenient;

7. ESS box load heating automatic adaptation.


technical specifications

Main technical parameters

model

WBE-LR2W-512LA

WBE-LR2W-512LB

WBE-LR2W-512LC

Internal volume (L)

512

512

512

Internal dimensions WxDxH (mm)

Width * Depth * Height

800×800×800mm

800×800×800mm

800×800×800mm

External dimensions WxDxH (mm)

Width * Depth * Height

2400x1972X2225mm

2400x1972X2225mm

2400x1972X2225mm

Window size W * H

Width * Height

W350*H500mm

Equipment noise (dB)

≤75dB

load

≤600W。

Storage temperature time

RT~200 ℃ requires approximately ≤ 30 minutes.

Cold storage temperature time

A: +20~-50 ℃ takes about 35 minutes

B: +20~-65 ℃ requires approximately ≤ 45 minutes

C: +20~-75 ℃ takes about 55 minutes

High temperature impact range

+60℃~ +150℃

Low temperature impact range

A:-10℃~ -40℃

B:-10℃~ -55℃

C:-10℃~ -65℃

Basket conversion time

5S。

Temperature recovery time

Within 5 minutes.

Exposure to high temperature for 15 minutes and exposure to low temperature for 15 minutes.

Continuous testing without defrosting frequency

1000 times (optional without defrosting midway).

Environmental temperature for use

Water cooling environment temperature requirement+5~+40 ℃ (water cooling requires installation of water tower or ice water machine)

system structure

Test the mobile product with a two box structure for preheating and pre cooling areas.

Weight (approximately) (Kg)

3100

3300

3500

Temperature fluctuation/uniformity

No load at ± 0.5 ℃/± 2.0 ℃.

Temperature and humidity time resolution

Temperature: 0.01 ℃; Humidity: 0.1%; Time: 0.01min.

Standard accessories

1 insulated glass observation window, 2 sample racks, measuring hole diameter of 50mm * 1, power cord, instruction manual.

power supply

AC380V ± 10%, 50Hz ± 1 three-phase four wire+grounding wire (3/N/PE), grounding resistance less than 4 Ω.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!