WAFD intelligent self diagnostic fieldbus distributor
WAFD intelligent self diagnostic fieldbus distributor
Product details


The intelligent self diagnostic fieldbus distributor (WAFD) can connect PROFIBUSPA equipment (such as pressure transmitters, differential pressure transmitters, temperature transmitters, and actuators) is connected to a self diagnostic fieldbus distributor (WAFD). Self diagnostic fieldbus distributor(WAFD)Can self diagnosePA



The connection and open/short circuit status of the main line, PA branch line, and PA equipment automatically isolates the faulty PA section, solves the communication interruption caused by PA section faults, and ensures the safe operation of the system.

Connection of on-site devices for PROFIBUS PA

• Automatic bus termination

• Isolate defective PA sections

After repairing the fault, connect the isolated PA section


Expand PA section during operation

PA main line uses 2 cable entry glands

4 PA field devices use 4 cable entry glands

Connect PROFIBUS PA main line and PA branch line through cage spring method

Reverse polarity protection connection

• Diagnose through LED

• Powered through PA bus

Tighten the inlet cover on the bottom layer, or install an adapter on the assembly guide rail



• Protection level IP66

Size and weightsizeW×H×Dmm

14057×80

×

weightmake an appointment

850 g

Voltage, current, potential

rated supply voltagesixteenVDC16 Varrive

32 V

Tmax35 V

Polarity reverse protectionhave

16PAPartial output voltage:

arrive32 VDC

Power failure bypass

5 mspower consumption

Usually it is10mAoutput currentPAPartial (used to indicate)

PA

The size of the configuration

1Apower loss

Usually it is

600mW

Status, Interruption, Diagnosis

Status display

not have

interrupt

not have

diagnostic functionhavestatePAprincipal linePA1

PA2

redLEDfaultPAprincipal linePA1

PA2

LEDextinguishstatePAbranch lineX1

arriveX4Device connection redLEbright/No device connection red

LEDextinguishfaultPAbranch lineX1

arriveX4red

LEDflickerUsed for selecting

PA

Data of on-site equipmentconnectPA

The total high power consumption of on-site equipment is1Ahave

PROFIBUSPA

Certified on-site equipment4The on-site equipment is located outside the hazardous areaMore connections available

individualPAField Deviceelectric currentImax proPA

branch lineX1