Dongguan Saice Testing Equipment Co., Ltd
Home>Products>Vibration Test SC-3-150
Vibration Test SC-3-150
Vibration Test SC-3-150
Product details

The air-cooled series electric vibration testing system has many advantages such as wide frequency, excellent indicators, high reliability, small footprint, easy mobility, and simple operation. Currently, there are multiple types of vibration tables available for selection in this series. The range of excitation force is from 1kN to 70kN, and the maximum load is from 70kg to 1000kg. Widely used in aviation, aerospace, weapons, ships, communications, automotive, electronics, electrical engineering, home appliances and other fields. We can provide comprehensive testing equipment for multiple environments such as climate and mechanics.
The vibration testing system is mainly used for conducting vibration and impact environment tests, environmental stress screening tests, reliability tests, and fatigue tests on products to assess their lifespan.

1. Productmajor function

The air-cooled series electric vibration testing system has many advantages such as wide frequency, excellent indicators, high reliability, small footprint, easy mobility, and simple operation. Currently, there are multiple types of vibration tables available for selection in this series. The range of excitation force is from 1kN to 70kN, and the maximum load is from 70kg to 1000kg. Widely used in aviation, aerospace, weapons, ships, communications, automotive, electronics, electrical engineering, home appliances and other fields. We can provide comprehensive testing equipment for multiple environments such as climate and mechanics.
The vibration testing system is mainly used for conducting vibration and impact environment tests, environmental stress screening tests, reliability tests, and fatigue tests on products to assess their lifespan.

2Productspecifications

2.1 Product Model

SC-3-150

2.2 Control instrument

amber

2.3 Power Supply

380V±10%,50Hz±0.5HZ;
Three phase four wire system+grounding wire;
TN-S power supply, TT power supply;
The protective grounding resistance is less than 4 Ω;
Require users to configure independent power sources of corresponding capacity at the installation site for equipment use;

2.4 Total power

About 20KV;

2.5. Total weight

About 530kg

2.6. Environmental conditions for use

The ambient temperature is 5-30 ℃ and the relative humidity is ≤ 85% R.H;
The installation site must be a flat and vibration free ground;
Keep the equipment away from heat sources and flammable and explosive substances;
The installation location should not be directly exposed to sunlight and maintain indoor air circulation;
The installation site needs to be clean and cannot be used in areas with high dust or sewage outlets;

2.7 System composition

The SC-3-150/VT0505/AMBER vibration test system equipment consists of an SC-3-150 electric vibration table, CZDA-3 switch mode power amplifier, VT0505 vertical expansion table, LT0505 horizontal expansion table, B-200 cooling fan, and AMBER vibration controller.
Additional countertops and fixtures can be optionally selected according to the needs of the user's test piece.
It can be paired with an environmental testing chamber to form a comprehensive environmental testing equipment.

2.8 System working diagram

remarks

3Main system configuration

Tai Ti

1. Vibration generator

SC-3-150;

2. Centering device

(including MPCS automatic centering device);

3. Cooling fan

B-200;

4. Vertical expansion table

VT0505;

5. Horizontal expansion table

LT0505 (Material: Aluminum Alloy)

power amplifier

1. Model number

SDA-3 digital switching power amplifier (including excitation power supply);

control apparatus

1. Control device

AMBER;

2. Channel

(2 channels, 4 functions)

3. Standard configuration

Window operating system, with diversified interface display;
(Acceleration, velocity, displacement, and curves can all be displayed);

4. Basic hardware configuration

19 inch computer (LCD monitor), HP color inkjet printer;

5. Software functions

Sine, random, typical shock, resonant search and dwell;

Accelerometer

1. DL100 piezoelectric accelerometer sensor

(including dedicated low-noise cables);

attachment

1. Cable line

special-purpose;

2. Accessory tools

special-purpose;

notes

4Main technical parameters

SC-3-150 body parameters

1. Rated sine excitation force (peak)

300kgf;

2. Rated random excitation force (rms)

300kgf;

3. Maximum impact excitation force (peak)

600kgf;

4. Frequency range

5~4000Hz;

5. Maximum displacement (P-P)

25mm;

6. Maximum speed

2.0m/s;

7. Maximum acceleration

1000 m/s2;

8. First-order resonant frequency

3400 Hz±5%;

9. Maximum load

120 kg;

10. Isolation frequency

2.0Hz;

11. Workbench diameter

Ф150 mm;

12. Equivalent mass of moving parts

3kg;

13. Desktop screws

13×M8;

14. Magnetic leakage

<1.0 MT;

15. Platform size

756mm × 618mm × 661mm (vertical platform) L × W × H

16. Weight of the platform

Approximately 995kg;

VT0505 Vertical Expansion Table

1. Materials

aluminium alloy;

2. Table size

500×500mm;

3. Sine upper limit usage frequency

2000Hz;

4. Random upper limit usage frequency

2000Hz;

5. Weight

About 20kg;

LT0505 Horizontal Expansion Table

1. Materials

aluminium alloy;

2. Table size

500×500mm;

3. Sine upper limit usage frequency

2000Hz;

4. Random upper limit usage frequency

2000Hz;

5. Weight

Approximately 25.5kg;

Power amplifier parameters

1. Model number

HD-SDA3

2. Output power

3kVA;

3. Output voltage

100V;

4. Output current

600A;

5. Input impedance

≥10kΩ;

6. Signal to noise ratio

≥65dB;

7. Harmonic distortion (resistive load)

<1.0%;

8. Output voltage error

≤5%;

9. Output current error

≤5%;

10. Peak coefficient of output current

≥3;

11. Frequency response 5-3500Hz

±3dB;

12. Intermediate frequency gain

≥80;

13. DC-AC conversion efficiency

>95%;

14. Load nature

Resistive, capacitive, and sensory are arbitrary;

15. Parallel current imbalance

≤3%;

16. Mean Time Between Failures (MTBF)

>3000 hours;

17. System protection

Overload protection, overheating protection, overcurrent protection, overvoltage protection, vibration controller output "0" position protection, over displacement protection, grid overvoltage and undervoltage protection, grid phase loss protection, timing protection, drive power protection, current limiting protection, module direct protection, module temperature protection

Cooling fan parameters

1. Fan model

B-200

2. Fan power

0.75 KW;

3. Fan flow rate:

0.1 m3/s;

4. Fan pressure

1kpa;

5. Duct length

4m;

6. Weight

30KG;

AMBER vibration controller (2 channels, 4 functions)

1. Basic functions

Sine, random, typical shock, resonant search and dwell;

System working environment requirements

1. Humidity

0-90% (non condensing);

2. Power requirements

380V/50Hz, 3 phases;

3. Compressed air requirements

0.6Mpa;

4. Laboratory grounding resistance (Ω)

≤2.5;