Product details

HAV angle regulating valve,The Venturi regulating valve is suitable for controlling fluids containing particles, mud, viscous or flash evaporation fluids. The leakage rate of the Venturi angle regulating electric valve meets the requirementsANSI B16.104Standard.

1HAVOverview of Venturi angle regulating electric valve

The HAV Venturi angle regulating valve core adopts an upward guide structure, with a compact valve structure, low pressure drop loss, high flow rate, and wide adjustable range. Suitable for controlling fluids and slurries containing particles, viscous or flashing fluids.

Venturi angle regulating valveThe leakage amount meets the requirementsANSI B16.104Standard. Equipped with a multi spring thin film actuator, it has a compact structure and high output force. The product complies withGB/T4213-92.

IIHAVVenturi angle regulating valve body

type Formula: Angle type single seat cast ball valve
Nominal diameter:2540506580100125150mm
Nominal pressure:ANSI 125150300 600 JIS 1016203040K PN1.64.06.4MPa
Connection type: flange connection:FFRFRJLGGroove type, embedded type
Flange standard:JIS B2201-1984ANSIB16.5-1981GB/T91129124-2000class
material Material: Cast steel(ZG230-450)Cast stainless steel(ZG1Cr18Ni9TiZG1Cr18Ni12Mo2TiZG00Cr18Ni12Mo2Ti)Titanium, etc

Upper valve cover: room temperature type(P):0+200
Extension Type I(E1): -450 +200+425
Note: The working temperature shall not exceed the allowable range of various materials
Cover type: bolt compression type
fill Material:VType PTFE packing, impregnated PTFE asbestos braided packing, asbestos braided packing, graphite packing

IIIHAVVenturi angle regulating valve internal components

Valve core type: single seat plunger valve core
Flow characteristics: percentage characteristics of metal valve seat, etc(%)And linear characteristics(L)Refer to the flow characteristic curve graph
Cv
Value from0.0414The high-precision flow characteristics comply withIEC534-2standard
Soft valve seat percentage characteristics(%)And linear characteristics(L)Refer to the flow characteristic curve graph
Note: For the working temperature and pressure difference of PTFE valve seats, refer to the flow characteristic curve diagram
material Material: Stainless steel(1Cr18Ni9Ti1Cr18Ni12Mo2Ti17-4PH9Cr18316L)Stainless steel overlay welding with Stellite alloy, titanium and corrosion-resistant alloys, etc

4HAVVenturi angle regulating valve actuator

type Formula:LHAMulti spring thin film actuatorLVA5Single spring thin film actuatorLVA6Single acting cylinder piston actuatorLVPDouble acting cylinder piston actuator
Diaphragm material: Ethylene propylene rubber with nylon cloth, butadiene rubberqingRubber clip nylon cloth
Spring range:2010080240kPaLHALVA5Type),190350190400kPaLVA6Type)
Gas supply pressure:140400kPaLHAType)140280kPaLVA5Type)400500kPaLVA6Type)300500kPaLVPType)
Gas source interface:Rc1/4'
Environmental temperature:-30+70
Function type: Use positive or negative action actuators to achieve valve gas-Guan or Qi-open
attach Components: Positioner, air filter pressure reducer, holding valve, travel switch, valve position transmitter, solenoid valve, handwheel mechanism, etc

5HAVPerformance of Venturi angle regulating valve

Leakage rate: Metal valve seat: Less than the rated capacity of the valve0.01%, in accordance withANSIB16.104-1976IVlevel
circle Poor: with locator: less than full stroke1%
Without locator: Less than full travel3%LHA1Type smaller than the full stroke5%
Basic error: with locator: less than ± of the full stroke1%
Without locator: less than ± of full travel5%
Note: Using standardVType PTFE packing
Adjustable range:5010.25Cv14)Or301CV0.16

VIHAVVenturi angle regulating valveCvValue and itinerary

Nominal Diameter

25

40

50

65

80

100

125

150

Valve seat diameter

20

25

32

25

32

40

32

40

50

40

50

65

50

65

80

65

80

100

80

100

125

ratedCvprice

1.0

1.6

2.5

4.0

6.3

10

11

17

24

17

24

44

24

44

68

44

68

99

68

99

175

99

175

275

175

275

395

Rated travel(mm

14.3

25

38

50

7HAVFlow characteristics of Venturi angle regulating valve

Typical flow characteristic curve

8HAVVenturi angle regulating valve allows pressure difference

MatchingLHAperhapsLVAactuator
Gas closed or gas open valve


execute
institution

air supply
pressure

Spring range

positioner

Allowable pressure difference

Valve seat diameter

Cv=
1.0,1.6

Cv=
2.5

Cv=
4.0,6.3

Cv=
11

25

32

40

50

65

80

100

125

LHA2D
LHA2R

1.4

0.21.0

with or without

40

40

40

40

21.9

10.1

6.8

4.1

2.5

1.8

-

-

2.8

0.82.4

have

40

40

40

40

40

20.1

13.7

8.2

5.0

3.6

-

-

LHA3D
LHA3R

1.4

0.21.0

with or without

-

-

-

-

-

17.9

12.1

7.2

4.5

3.2

1.8

1.2

2.8

0.82.4

have

-

-

-

-

-

35.7

24.2

14.5

8.9

6.4

3.6

2.3


LHA4D
LHA4R

1.4

0.21.0

with or without

-

-

-

-

-

30.9

20.9

12.5

7.7

5.6

3.1

2.0

2.8

0.82.4

have

-

-

-

-

-

40

40

25

5.4

11.1

6.2

4.0

LVA5D
LHA5R

1.4

0.21.0

with or without

-

-

-

-

-

-

-

16

10

7.5

4.2

2.7

2.8

0.42.0

have

-

-

-

-

-

-

-

32

21

15

8.5

5.4

LVA5R

5

1.94.0

have

-

-

-

-

-

-

-

-

-

-

9.1

5.8

pour: oneThe maximum allowable pressure difference shall not exceedANSI B16.34perhapsJIS B2201The high work pressure specified by the standard.
2
The numbers in the black box indicate the standard specification actuator for the valve.

9HAVVenturi angle regulating valve flange distance and external dimensions

flange distance

Valve size
B

A

ANSI 125 FF
ANSI 150 RF
JIS 10K FF RF
PN1.6

JIS 16K RF

JIS 20K RF
JIS 30K RF
ANSI 300 RF
PN4.0

JIS 40K RF
ANSI 600 RF
PN6.4

ANSI 150RJ

ANSI 300RJ

ANSI 600RJ

ANSI 300LG

ANSI 600LG

25

92

98

98

105

98

105

105

105

105

40

111

117

117

125

117

124

125

124

125

50

127

133

133

143

133

141

144

141

144

65

138

146

146

156

144

154

157

154

157

80

149

159

159

168

156

167

170

167

170

100

176

184

184

197

183

192

198

192

198

125

202

213

213

229

208

221

230

221

230

150

225

237

237

254

232

244

256

244

256

pour:The flange distance meets the requirementsIEC534-3standard

External dimensions


LHAactuator

LHA5actuator

LHA6actuator

LVPactuator


Nominal Diameter

actuator

H

B

φB

Room temperature type upper valve cover

Extended upper valve cover

Valve cover on corrugated pipe

25

LHA1DR

390

545

545

230

218

LHA2DR

465

620

-

281

267

40

LHA1DR

400

550

560

230

218

LHA2DR

475

625

-

281

267

LHA3DR

580

730

-

363

350

LHA4DR

830

975

-

520

470

50

LHA1DR

400

550

560

230

218

LHA2DR

475

625

-

281

267

LHA3DR

580

730

-

363

350

LHA4DR

835

980

-

520

470

65

LHA2DR

545

695

765

281

267

LHA3DR

600

750

-

363

350

LHA4DR

840

990

-

520

470

LVA5D

1225

1375

-

-

620

LVA5R

1335

1485

-

-

620

80

LHA2DR

555

705

775

281

267

LHA3DR

610

760

-

363

350

LHA4DR

840

990

-

520

470

LVA5D

1225

1375

-

-

620

LVA5R

1335

1485

-

-

620

100

LHA2DR

555

710

775

281

267

LHA3DR

610

765

-

263

350

LHA4DR

845

995

-

520

470

LVA5D

1230

1380

-

-

620

LVA5R

1340

1490

990

-

620

125

LHA3DR

700

850

-

363

350

LHA4DR

865

1015

-

520

470

LVA5D

1255

1405

-

-

620

LVA5R

1365

1515

1005

-

620

150

LHA3DR

720

870

-

363

350

LHA4DR

885

1035

-

520

470

LVA5D

1275

1425

-

-

620

LVA5R

1385

1535

-

-

620

Note: On the tableHThe column size refers to the data of the regulating valve without a handwheel mechanism. If it has a top mounted handwheel mechanism, the size of the handwheel mechanism should be added accordingly.

10HAVOrdering Notice for Venturi Angle Regulating Valve

1. Name and parameters of Venturi angle regulating valve

2. Diameter of Venturi angle regulating valve

3. Flow characteristics of Venturi angle regulating valve

4. Venturi angle regulating valve pressure difference (including normal working pressure difference and pressure difference when the valve is closed)

5. Material of the valve body and internal components of the Venturi angle regulating valve

6. Venturi angle regulating valve medium and medium temperature

7. Corrosion resistance and accessories of Venturi angle regulating valve

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!