Vaisala BAROCAP Barometer PTB110 Atmospheric Pressure Sensor
Vaisala HUMICAP? sensor
Multiple pressure measurement ranges
+Accuracy of ± 0.3 hPa at 20 ° C
long-term stability
Can be controlled on/off through external triggers
The output voltage is 0 .. 2.5 or 0 .. 5 VDC
Current consumption below 4 mA
Can be installed on a (35mm wide) DIN rail
Traceable National Institute of Standards and Technology (NIST) calibration certificate (including certificate)
Technical parameters of atmospheric pressure sensor
Scope of work (1 hPa=1 mbar)
?
Pressure range?
?
?
?500 … 1100 hPa
?
?
?600 … 1100 hPa
?
?
?800 … 1100 hPa
?
?
?800 … 1060 hPa
?
?
?600 … 1060 hPa
?
Total accuracy at+20 ° C? ± 0.3 hPa
?
Atmospheric pressure sensor? BAROCAP?
working environment
temperature range
humidity range
-40 . .. +60 °C (-40 ... +140 °F)
No condensation
Working voltage of atmospheric pressure sensor
10 . .. 30 VDC
?
Power consumption?
?
The working mode is below 4 mA
?
The shutdown mode is below 1 μ A
?
Output voltage? 0 .. 2.5 VDC
?
?
?0 . .. 5 VDC
Other indicators
weight
Material (shell)
90 grams
Plastic cover, ABS/PC hybrid material