V-series V-cone flowmeter
The V-cone flowmeter is a differential pressure instrument that measures fluid flow inside a pipe based on the laws of conservation of mass and energy
Product details

VCone flowmeter is a differential pressure instrument that measures the fluid flow inside a pipe based on the laws of conservation of mass and energy. It innovatively utilizes the suspension at the center of the pipelineVAs a throttling component, the conical structure has unique advantages of self rectification and self-cleaning. It is a new type of instrument with a wide range of applications.
Product Features
The special structure is suitable for measuring low static pressure and low flow rate flow.
★VCone flowmeter self-cleaning function, when the fluid passes throughVWhen forming a cone, the flow velocity at the center of the pipeline slows down and the flow velocity near the pipe wall increases, making it difficult for dirt to deposit on the throttling element, which is beneficial for accurate and stable measurement.
★VThe cone flowmeter has self rectification function,VThe characteristic of a conical shape, which can slow down the flow velocity at the center of the pipeline and increase the flow velocity near the pipe wall, effectively improves the distribution of fluid flow velocity, achieves self rectification, and greatly shortens the length of the straight pipe before and after, as long as it reaches the front0~3DNAfterwards0~1DNJust enough.
★ Good wear resistance, long-term stability, and high measurement repeatability.
★ The special structure has low pressure loss, and its pressure loss is due to the orifice plate1/3~1/5The range ratio is10:1(Special accessibility)30:1).
Due to the unique structure of the conical flowmeter, it is often used as a mixer in many cases.
★ Suitable for high working temperatures450℃, maximum pressure42MPaIf special materials are used, the range is higher.
For the convenience of users, our companyVCone flow meters have integrated and split structures.
★ Intelligent integrationVCone flowmeter adopts advanced circuit design, powerful functions, low power consumption, large screen LCD display of flow information, and advanced internal memory to ensure data security.
★ IntegrationVCone flowmeter system, can be powered by batteries and external24VDCPower supply, output4~20mAPulse signal, there isHartagreement.
Flow meter model specification table
VCone flowmeter
|
Selection instructions
|
||||||||
Nominal Diameter
|
-XXX
|
100showDN100
|
|||||||
structural style
|
Z
|
Intelligent integration
|
|||||||
L
|
split type
|
||||||||
Measurement medium
|
1
|
liquid
|
|||||||
2
|
gas
|
||||||||
3
|
steam
|
||||||||
Ontological form
|
S
|
Pipeline typeSO(with neck flat welding flange connection method)
|
|||||||
W
|
Pipeline typeWN(Neck welding flange connection method)
|
||||||||
F
|
Flange pressure tapping method
|
||||||||
B
|
Direct welding type
|
||||||||
J
|
Insulation jacket type
|
||||||||
A
|
Anti-corrosion type
|
||||||||
P
|
Square tube shape
|
||||||||
H
|
Pipe clamp type
|
||||||||
Pipeline static pressure
|
A
|
0~0.6MPa
|
|||||||
B
|
0~1.0MPa
|
||||||||
C
|
0~1.6MPa
|
||||||||
D
|
0~2.5MPa
|
||||||||
E
|
0~4.0MPa
|
||||||||
F
|
0~6.3MPa
|
||||||||
G
|
0~10MPa
|
||||||||
H
|
0~16MPa
|
||||||||
I
|
0~25MPa
|
||||||||
J
|
0~40MPa
|
||||||||
Compensation method
|
0
|
No compensation
|
|||||||
P
|
Single pressure compensation
|
||||||||
T
|
Single temperature compensation
|
||||||||
Q
|
Full compensation for pressure and temperature
|
||||||||
Integrated signal output
|
0
|
not have
|
|||||||
1
|
4~20Ma
|
||||||||
2
|
pulse
|
||||||||
3
|
Hart
|
||||||||
Integrated power supply mode
|
0
|
Internal battery power supply
|
|||||||
1
|
Battery and24VDCDual choice power supply
|
||||||||
2
|
outside24VDCpower supply
|
Provide the inner and outer diameters of the pipeline and the material of the pipeline.
Specify the flange specifications for the process pipeline.
Indicate the type of liquid, gas and vapor properties.