Coliynuclear radiationClassification List | |||||
Detectable radiation |
PRODUCT MODEL |
sensor |
range |
γX-ray sensitivity(Cs137,1µSv/h) |
characteristic |
portable | |||||
α、β |
R900 |
ZINC SULFIDE+plastic scintillator |
1Mcps |
-- |
Effective area1702 |
R700 |
ZINC SULFIDE+plastic scintillator |
1Mcps |
-- |
Effective area750px2 |
|
α、β、γ |
R500 |
Geiger counter |
1mSv/h |
7cps |
Large end window cover leather pipe Unable to distinguish the type of radiation |
910 |
Geiger counter |
1mSv/h |
2cps |
Small end window cover leather tube Unable to distinguish the type of radiation |
|
R800 |
CZTsemiconductor |
γ:10mSv/h β:1mSv/h |
7cps |
Simultaneously measuring andDistinguish displayα、βandγray |
|
γ |
RS10 Energy spectrum analyzer |
Φ50x50mmsodium iodide |
1mSv/h |
800cps |
Spectral analysis, energy resolution<> |
10x10x10mm3cadmium zinc telluride |
10mSv/h |
60cps |
Spectral analysis, energy resolution<> |
||
R100 |
GMcounter tube (After energy compensation) |
100mSv/h |
2cps |
persondoseAlarm device, energy range20keV~3MeV |
|
R750 |
Φ80x80mm plastic scintillator |
0.2mSv/h |
2000cps |
Environmental grade, ultra-high sensitivity Energy Range15keV~7MeV(±15%) |
|
RW10 |
φ35×35mmsodium iodide |
1.5mSv/h |
400cps |
100Continuous underwater work |
|
ION-H |
Radiation resistant scintillation sensor |
100Sv/h |
77cps |
High range measurement, optional range10Sv/h、 20Sv/h、50Sv/h、100Sv/h |
|
R700 |
Φ75x75mmplastic scintillator |
0.2mSv/h |
1500cps |
Environmental grade, high sensitivity |
|
R700 |
Φ30x30mmsodium iodide |
1mSv/h |
350cps |
answerγHigh radiation detection efficiency、1Quick response in seconds |
|
RC510 γX-ray imaging |
GAGGcrystal |
10mSv/h |
500cps |
High sensitivity sensor, encoding hole imaging technology Quickly identify and locate radiation sources |
|
Neutronsγ |
R60N |
10×10×10(mm3)Koley PatentHType sensor |
10mSv/h(Neutron) |
0.5cps(Cf-252 ) |
A single sensor can simultaneously detect neutrons andγray γPSRR≥1000:1 High sensitivity under the same volume3Hesensor20times |
20×20×20(mm3)Koley PatentHType sensor |
2.7cps(Cf-252 ) |
||||
Wall mountedR2000 | |||||
γ
|
GM30A |
Geiger counter |
1mSv/h |
2cps |
Small end window cover leather tube X、γEnergy response:50keV-3MeV |
CS30A |
Φ30x30mm plastic scintillator |
1mSv/h |
350cps |
1Quick response in seconds |
|
CS75 |
Φ75x75mmplastic scintillator |
0.2mSv/h |
1500cps |
Environmental grade High sensitivity |
|
Neutronsγ |
N10 |
10×10×10(mm3)Koley PatentHType sensor |
10mSv/h(neutron) |
0.5cps(Cf-252 ) |
A single sensor can simultaneously detect neutrons andγray γPSRR≥1000:1 High sensitivity under the same volume3Hesensor20times |
N20 |
20×20×20(mm3)Koley PatentHType sensor |
2.7cps(Cf-252 )
|

brief introduction
Latest research and development by Koley Companyofauxiliary word for ordinal numbersSecond generation superhigh rangeX(γ)Nuclear power dedicated detectorION-HuseImported energy compensation typeGMsensor, Range30Sv/hperhaps100Sv/h,DevelopedThe brand new technology greatly reduces the size of the product, currentlyprobeSize as low asφ34mm×142mmThe mini design greatly expands the application space and meets the diverse needs of users;ION-HIntegrated automationrangeSwitching technologies,Range span reached107,Minimum resolution10μSv/h. Encapsulated with radiation resistant materialsandGMTube life enhancement technology,Can be in100Sv/hContinuous operation in the environment300hour.
exceedhigh rangeX(γ)Nuclear power dedicated detectorION-HHas high sensitivity, wide measurement range, high accuracy, strong anti-interference ability, good stability, and wide application range, radiation resistance, etcFeatures, standard configurationRS485Output, working power supply is5VDC, can be connected externallyMy company'sR700andR2000The host serves as a display,It can also be done directly throughRS485givePLCComputer and other communicationThe development of this feature ensures the measurement accuracy of the probe and enhances its environmental adaptability.
application
exceedhigh rangeX(γ)Nuclear power dedicated detectorION-HNot only applicable to the nuclear power industry, but also widely used in laboratories、power plant、Emergency rescue station、Metal processing plant、Oilfield and oil supply pipeline equipment、Environmental protection and other departments.
Main technical parameters
Probe model |
ION-H30 |
ION-H100 |
Dose rate range |
10μSv/h-30Sv/h |
10μSv/h-100Sv/h |
service life |
>30Sv/hbelowcontinuous operation1000hour |
>100Sv/hbelowcontinuous operation300hour |
size |
Φ34mm×142mm |
|
detector |
energy compensationGMpipe |
|
Minimum resolution |
10μSv/h |
|
Measure the type of radiation |
X、γray |
|
Probe performance |
Radiation resistant packaging,GMTube life enhancement technology,Exceeding the standard of measurement10Double does not damage the service life. |
|
design methods |
Adopting a design approach that combines sensors and electronic circuits |
|
Energy Response |
50keV~3MeV(≤30%) |
|
accuracy |
≤±15%(Co-60) |
|
Length |
Customizable according to user needs |
|
Overload characteristics |
10Double overload |
|
output port |
RS485Protocol output |
|
relative humidity |
≤95% R.H (No condensation) |
|
operation temperature |
-20℃~+60℃ |
|
storage temperature |
-30℃~+70℃ |
|
Working pressure |
86kPa~106kPa |
|
power supply |
5VDC |
|
Expansion items |
Can be connected externallyR700andR2000Host display |