HI1083P Ultra fine open glass composite acidity pH electrode【Ball shaped sensor】 |
|
Suitable for small caliber samples, biological samples, and trace amounts< 100µLWaiting for sample measurement | |
scope of application:0 to 13 pH; Sample temperature: 0 to 50 ° C (32 to 122 ° F),Sensor type:conical【Ø3mm】 | |
Electrode characteristics: Single reference【Ag/AgCl】The,open typeDialysis membrane; | |
Maximum pressure:0.1bar;interface type:BNC+PIN,1Rice noodle length,Electrode material:General vitreous body GP,Electrode size:120mm ר3mm | |
![]() |
Universal glass material As the name suggests, General Purpose (GP) glass is a standard glass material used for general purposes. PH electrode with GP glass25 ° CThe resistance at that time is100Megaohms, suitable for measuring samples at ambient temperaturepHValue measurement. Microsphere shaped sensor 3 mmThe design of microsphere sensors allows for measurements smaller than100μLMeasure in the sample. In the field of biotechnology, samples may need to be in test tubes, sample bottles, andNMRMeasure in the tube. GLASS Glass electrodes are very suitable for laboratory use. This glass can withstand many irritating chemicals and is easy to clean. Glass electrodes also allow for rapid transfer of heat to the internal reference electrolyte. Generated by reference potentialmVRelated to temperature. The faster the balance, the more stable the reference potential. |
![]() |
Open dialysis membrane design Suspended solids and proteins in food can clog traditional ceramic reference dialysis membranes, hindering the measurement circuit between the indicator electrode and internal reference, resulting in slower response time, unstable readings, and frequent electrode replacement. Open structure design includes samples and internal componentsAg / AgClSolid gel interface (viscoelastic body) between references. This interface not only prevents silver from entering the sample, but also prevents blockage, thereby achieving fast response and stable readings. |
Acidity electrode maintenance, upkeep, and preservation plan | |
![]() |
HI70300 Customized specialized electrode preservation solution Specially formulated with high-purity chemical reagents and high-quality deionized water, rigorously certified with various measuring tools and containers, carefully formulated in a temperature and humidity environment that meets the requirements, and traceableNISTstandard reference materials(SRM); Hanna brand electrode preservation solution, formulated with a special formula to minimize bacterial growth on the electrode, adopts a unique tamper proof sealing setting to ensure the quality and freshness of the electrode preservation solution, If the acidity electrode glass sensing membrane or dialysis membrane head is found to be dry, the electrode should be soaked inHI70300At least in the electrode preservation solution1More than an hour. |
![]() |
After using the electrode, it is necessary to immediately use a specialized cleaning solution, which is an indispensable step to ensure the service life and response time of the electrode. According to the different samples being measured, the corresponding electrode cleaning solution should be selected: |