Ulide UT3042B
Ulide UT3042B
Product details
Ulide UT3042B

TECHNICAL INDEX

basic function
Technical indicators
passageway
2
bandwidth
40MHz
Sampling method
real-time sampling
500MS/s
equivalent sampling
25GS/s
average value
2 to the power of n, selectable from 2 to 256 times.
input
Input coupling
DC, AC, Ground (DC, AC, GND)
Input impedance
1 ± 2% Μ Ω, parallel with 24 ± 3pF
Probe attenuation coefficient setting
1X,10X,100X,1000X
*Large input voltage
400V (DC+AC peak, 1 Μ Ω input impedance) (10:1 probe attenuation)
Isolation between channels
Better than 40:1
Inter channel time delay (typical)
150ps
level
waveform interpolation
sin(x)/x
Recording and Storage
Storage depth: 1M sampling points
Scanning range (S/div)
5ns/div ~ 50s/div, 1-2-5 base (60MHz, 80MHz, 100MHz)
Sampling rate and delay time * * degrees
± 100ppm (any time interval ≥ 1ms)
Time interval (△ T)
Measure * * degrees (full bandwidth)
Single time: ± (1 sampling interval+100ppm x reading+0.6ns)>16 average values: ± (1 sampling interval+100ppm x reading+0.4ns)
vertical
Analog to Digital Converter (A/D)
8-bit resolution, simultaneous sampling of two channels
deflection factor
2mV/div~5V/div (at input BNC)
Displacement range
±10div
analog bandwidth
40MHz
Optional simulation bandwidth limitations, typical
20MHz
Low frequency response (AC coupling, -3dB)
≤ 10Hz (on BNC)
Rise time (typical on BNC)
<8.7ns
DC gain * * degrees
2mv/div, ± 4% at 5mv/div (sampling or average sampling method);
When 10mv/div~5v/div: ± 3% (sampling or average sampling method)
DC measurement * * degrees (average sampling method)
When the vertical displacement is zero and N ≥ 16: ± (4% x reading+0.1div+1mV); Vertical deflection coefficient ≥ 5mV/div; When N ≥ 16: ± [3% x (reading+vertical displacement reading)+(1% x vertical displacement reading)]+0.2div) vertical deflection coefficient from 2mV/div to 200mV/div plus 2mV; vertical deflection coefficient from 500mV/div to 5V/div plus 50mV
Voltage difference (Δ V) measurement accuracy (average sampling method)
Under the same settings and environmental conditions, after taking the average of ≥ 16 captured waveforms, the voltage difference (Δ V) between any two points on the waveform is ± (3% x reading+0.05div)
trigger
Trigger sensitivity
DC~10MHz 0.5div 10MHz~Maximum bandwidth 1div
Trigger level range
internal
± 10div from the center of the screen
EXT
±1.6V
EXT/5
±8V
Trigger level * * degree (typical) * * degree is suitable for signals with rise and fall times ≥ 20ns
inside
± (0.3div × V/div) (within ± 4div from the center of the screen)
EXT
± (6% set value+40mV)
EXT/5
± (6% set value+200mV)
Pre triggering capability
Normal mode/scanning mode, pre trigger/delayed trigger, pre trigger depth adjustable
Release range
100ns-1.5s
Set the voltage level to 50% (typical)
Operation under the condition of input signal frequency ≥ 50Hz
Edge triggered
Edge type
Rising and falling
Pulse width triggering
Trigger mode
(greater than, less than, equal to) positive pulse width, (greater than, less than, equal to) negative pulse width
Pulse width range
20ns-10s
Video trigger
Trigger sensitivity
(Video triggered, typical)
internal
2div peak to peak value
EXT
400mV
EXT/5
2V
Signal system and line/field
Frequency (video trigger type)
Supports standard NTSC and PAL formats, with a line range of 1-525 (NTSC) and 1-625 (PAL)
Alternating triggering
CH1 trigger
Edge, pulse width, video
CH2 trigger
Edge, pulse width, video
measure
cursor
Manual mode
Voltage difference between cursor (Δ V), time difference between cursor (Δ T), reciprocal of Δ T (Hz) (1/Δ T)
Tracking mode
Voltage and time values of waveform points
automatic measurement
Measurement of peak to peak value, amplitude, * large value, * small value, top value, bottom value, average value, root mean square value, overshoot, overshoot, frequency, cycle, rise time, fall time, positive pulse width, negative pulse width, positive duty cycle, negative duty cycle, delay 1->2 (rise), delay 1->2 (fall)
Mathematical operations
Add, subtract, multiply, divide, invert
Stored Waveforms
10 sets of waveforms, 10 settings
FFT
Window
Hanning,Hamming,Blackman,Rectangular
Sampling point
1024 points
lissajous figures
phase difference
±3 degrees
display
display type
The diagonal is 145 millimeters (5.7 inches) LCD display
Display Resolution (Display)
320 horizontal x RGB x 240 vertical pixels (monochrome)
Display Color
monochrome
Display contrast
Adjustable
Backlight intensity (typical)
300nit
Display language types
Simplified Chinese, Traditional Chinese, English
Probe compensator output
Output voltage (typical)
About 3V, peak to peak ≥ 1M Ω load
Frequency (typical)
1kHz
Interface function
Standard configuration
1 USB (D); 1 USB (H); 1 RS-232C
Select accessories
GPIB and LAN
Power Supply
supply voltage
100-240VAC RMS 45Hz to 440Hz, CAT II
consume power
Less than 30VA
fuse
2A, T-class, 250V
Environmental Science
temperature
Operation: 0 ℃~+40 ℃
Non operational: -20 ℃ to+60 ℃
cooling method
convection
humidity
+10℃~+30℃:≤95%±5%RH,
+30℃~+40℃:≤75%±5%RH
height
Operate 3000 meters
Non operational 15000 meters
Mechanical specifications
size
320mm (width) x 150mm (height) x 292mm (depth)
Weight (net weight)
Excluding packaging
4.9kg
Including packaging
6.8 kg
IP protection
IP2X
Ulide UT3042B