UQZ-53Z magnetic float level transmitter
The UHZ-52Z series side mounted magnetic flip column level gauge is a product developed and produced by our factory based on the magnetic level gauge
Product details

The U HZ-52Z series side mounted magnetic flip column level gauge is a product developed and produced by our factory based on the magnetic level gauge standard HG/T 21584-95 issued by the former Ministry of Chemical Industry, after introducing and absorbing similar foreign products, and absorbing, digesting, and improving them. Can be used for medium level detection in equipment such as towers, tanks, tanks, spherical containers, and boilers. This series of magnetic level gauges can achieve high sealing and leak prevention, and are suitable for measuring liquid levels in high-pressure, high-temperature, and corrosive media. They are reliable and safe to use. They make up for the shortcomings of glass plate (tube) level gauges, such as unclear indication and easy breakage, and are not affected by high and low temperature fluctuations. They do not require the combination of multiple sets of level gauges. The entire measurement process has no blind spots, eye-catching display, intuitive readings, and a large measurement range, especially in the on-site indication part. Since it does not come into direct contact with liquid media, it is more superior to high temperature, high pressure, high viscosity, toxic, harmful, and highly corrosive media. Therefore, it is more reliable, safe, progressiveness and practical than the traditional glass tube and plate level gauge. The most significant feature of the side mounted magnetic flip column level gauge is that the liquid medium is completely isolated from the indicator, making it very safe, reliable, and durable in any situation. Various models of level gauges are equipped with level alarms and control switches, which can achieve upper and lower limit alarms, control, or interlocking of the liquid level or boundary. When equipped with static pressure level transmitters or dry spring resistance level transmitters, the liquid level and boundary signals can be converted into two-wire 4-20mADC standard signals, realizing remote indication, detection, recording, and control. This series of side mounted magnetic flip column level gauges can be widely used for level measurement and control in various industries such as power, petroleum, chemical, metallurgical, environmental protection, shipbuilding, construction, and food production processes.

characteristic

Suitable for measuring the liquid level and boundary position of liquid media in containers. In addition to on-site instructions, it can also be equipped with remote transmitters, alarm switches, and control switches, with complete detection functions.

The indication is novel, the reading is intuitive and eye-catching, and the direction of the observation indicator can be changed according to the user's needs.

The measurement range is large and not limited by the height of the storage tank.

The indicating mechanism is completely isolated from the tested medium, resulting in good sealing, high reliability, and safe use.

● Simple structure, easy installation, low maintenance cost, magnetic float and magnetic flip column indicator

Corrosion resistant, no need for power supply, explosion-proof


structural principle

The liquid level gauge is developed based on the principle of buoyancy and magnetic coupling. When the liquid level in the tested container rises or falls, the float in the main tube of the level gauge also rises or falls accordingly. The permanent magnetic steel inside the float is transmitted to the on-site indicator through magnetic coupling, driving the red and white flip columns to flip 180 °. When the liquid level rises, the flip column changes from white to red, and when the liquid level drops, it changes from red to white. The red and white boundary of the indicator is the actual height of the medium liquid level in the container, thus achieving liquid level indication.


Comparison Table of Liquid Medium Density and Sinking Cylinder Distance (PN 1.6~40. MPa)


Density of liquid medium

(g/cm)

Sinking distance M

(mm)

Typical examples of liquid media
0.45~0.60 320~380 Liquefied petroleum gas, liquid ammonia, ethylene, hydrogen cyanide, ethane
0.61~0.74 260~320 Gasoline, butadiene
0.75~0.85 230~260 Methanol, epoxy (propane), xylene, light oil, ethanol
0.86~0.99 200~230 Acetone, ammonia water, coarse benzene, beer, heavy alcohol, beef fat, ethylbenzene
1.00~1.10 180~200 Water, acetic acid, camphor oil
1.11~1.25 160~180 Hydrochloric acid, tar, chlorosulfonic acid, nitrobenzene, FR-22
1.26~1.39 140~160 Liquid alkali, maltose, 20% dilute sulfuric acid, dimethyl sulfate
1.40~1.59 120~140 Liquid chlorine, dilute sulfuric acid, concentrated nitric acid, FR-12, chloroform
1.60~2.00 100~120 98% sulfuric acid, fuming sulfuric acid, perchloric acid, bromophosphoric acid, fluorine oil





technical parameters

Measurement range: 0-6000mm

Nominal pressure: 1.62.5MPa

公称通称: 150mm

Medium temperature: -40~135 ℃

Measurement accuracy: ± 10mm

Medium density: ≥ 0.55g/cm

Power supply: 24VDC (220VAC)

Output signal: 4~20mADC

Explosion proof grade: Explosion proof type: dIIBT6