v-bestTwo slot HAST high-pressure accelerated aging chamber2-Zone HAST CHAMBER is used for high voltage, high temperature, unsaturated/saturated wet heat, and other accelerated life reliability tests on IC packaging, semiconductors, microelectronic chips, magnetic materials, and other electronic components.
►Adopting a dual slot design with upper and lower compartments, saving laboratory space,The price of one machine equals the value of two machinesReduce equipment usage costs.
►Single screen dual control reduces complex and cumbersome settings, meets the simultaneous testing of different samples, and improves testing efficiency.
►96 channel bias terminal design to meet chip bias testing requirements.
►The product is compatible with HAST unsaturated high-pressure steam constant humidity test and PCT saturated high-pressure steam test.
►Automatic box door design, button controlled box door opening and closing, with built-in pressure protection.
application area:
Used for PCBs, IC semiconductors, connectors, circuit boards, magnetic materials, polymer materials EVA、 Accelerated aging life testing of products related to the photovoltaic module industry
Meet standards:
AEC-Q100-REV-J
AEC-Q101-REV-E
JIS C0096-2
GB/T2423.40-1997 Environmental testing for electrical and electronic products Part 2: Test methods Cx: Constant humidity and heat of unsaturated high-pressure steam
IEC60068-2-66-1994 Environmental Testing Part 2-66: Test Methods Test Cx: Steady state Damp Heat
Temperature and humidity offset lifetime of JESD22-A100 cycle
JESD22-A101 steady-state temperature, humidity/bias voltage, life test (temperature humidity bias voltage life)
JESD22-A102 High Pressure Steaming Test (Accelerated Moisture Resistance Penetration)
JESD22-A108 Temperature, Bias Voltage, and Operating Life
JESD22-A110 HAST High Acceleration Temperature and Humidity Stress Test
JESD22-A118 High Acceleration Stress Experiment without Bias Voltage UHAST (Unsaturated High Voltage Steam without Bias Voltage)
*Customizable to any parameter specification and model size
Two slot HAST high-pressure accelerated aging chamber | |||||
modelModel | WBE-2HAST-30 | WBE-2HAST-40 | WBE-2HAST-55 | WBE-2HAST-65 | |
Single slot capacity(L) | 31 L | 69 L | 154 L | 248 L | |
inside dimensions (mm) |
Diameter φ | 350 | 400 | 550 | 650 |
Deep D | 450 | 550 | 650 | 750 | |
Carton size (mm) |
Width W | 700 | 700 | 850 | 950 |
Deep D | 1000 | 1000 | 1150 | 1350 | |
High H | 1710 | 1710 | 1760 | 1860 | |
performance index | temperature range |
A: +100~+143℃; B: +100~+156℃ |
|||
Humidity range | 60%~100%RH | ||||
Pressure Range |
A:0.2~3kg/cm² (0.018~0.294Mpa); B:0.2~4kg/cm² (0.018~0.394Mpa) |
||||
temperature uniformity | ≤±2℃ | ||||
temperature fluctuation | ≤±0.5℃ | ||||
Humidity fluctuation | ≤±2 % R.H | ||||
Humidity deviation | ≤±3 % R.H | ||||
Temperature deviation | ≤±2℃ | ||||
Pressure deviation | ≤±2Kpa | ||||
heating up time | Room temperature~+143 ℃ for about 45 minutes; Room temperature~+156 ℃ for about 55 minutes | ||||
Rise time | Normal pressure~3kg/cm ² for about 35 minutes, external gas source pressurization: about 5 minutes | ||||
power | 2.8KW | 3.2KW | 4KW | 5KW | |
Cabinet material | Inner box | SUS # 316 stainless steel | |||
Outer box | Cold rolled steel plate+double-sided electrostatic spraying process treatment | ||||
heat preservation | Superfine glass wool | ||||
noise | ≤60(dB) | ||||
controller | 7-inch color touch screen controller (with pressure, temperature and humidity, RS-485 or RS-232 communication, USB baking data) | ||||
resolution | Temperature: 0.01 ℃; Humidity: 0.1% RH; Pressure: 0.1 kg/cm ²; | ||||
Way of Pressure | 1. Boiler steam pressurization; 2. External gas pressurization | ||||
BIAS bias terminal |
(Please specify when placing an optional order) |
||||
Conditions of Use | Environmental temperature:+5 ℃~+35 ℃; Environmental humidity: ≤ 85% RH; Environmental atmospheric pressure requirement: 86KPa~106KPa | ||||
power supply | AC220V 50/60Hz | ||||
Protector | 1. Over temperature protection, 2. Fan overload protection, 3. Box door pressure protection, 4. Water shortage protection, 5. Overflow protection, 6. Heater air burn protection, 7. Heater overload protection, 8. Power phase loss protection, 9. Overcurrent protection, 10. Short circuit leakage protection, etc |