Product Display

Hardware composition:
1. liquid storage tank1Only(4m x 2mx 1.6m, can be customized according to actual situations)
2. Test tank1only
3. Stainless steel temperature controlled water tank1only
4. seawater pump3only
5. Cooling and Heating Unit1set
6. hot air blower1set
7. Lighting facilities1set
8. level sensor1set
9. control system1Set with touch screen programmable instrument
10. stainless steel bracket2set
Technical Specifications:
1. Equipped with constant temperature function, the temperature can be set20±5℃
2. The liquid level of the test tank solution can be adjusted
3. The air drying system of the test tank is automatically controlled, and the time can be set. The wind speed at the center point is determined according to10 m/sdesign
4. During the soaking process,water tankMaintain a constant temperature of the seawater in the test tank through single circulation with the seawater in the test tank
5. The wet dry cycle process is fully automatic, and the time can be programmed through the touch screen instrument
6. The drying process can selectively turn on the baking light
The accessories are as follows:
|
serial number |
Specification Model |
quantity |
|
1 |
Model of self-priming centrifugal water pump50ZX15-12-1.5KW Special for seawater, stainless steel pump body |
3Taiwan |
|
2 |
Emerson Refrigeration CompressorZR72 |
1Taiwan |
|
3 |
Air cooled condenser and refrigeration accessories |
1set |
|
4 |
Box processing |
1set |
|
5 |
Stainless steel evaporator and evaporator water tank |
1set |
|
6 |
Blower heating system |
1set |
|
7 |
Programmable touch screen instrument, control and circuit parts |
1set |
|
8 |
Stainless steel bracket, including compressor and heating system bracket |
2set |
|
9 |
Lighting system |
1set |
Experimental procedure:
1. Program settings on the instrument, including test soaking temperature, soaking time, air drying time, whether light irradiation is required, number of cycles, etc
2. Set the height of the liquid level sensor based on the actual height of the sample
3. Inject enough test solution into the storage tank to ensure that the solution can completely submerge the samples in the sample tank
4. Fill the circulating water tank with the test solution
5. Reasonably place the test samples and try to ensure that they can be evenly dried and illuminated by light
6. Check the preparation work for the test, start up and run, and automatically complete all tests
7. During the mid-term of the experiment, attention should be paid to the volume and concentration of the test solution, and appropriate supplementation should be made