VIP member
Tianjiu Machinery NJP-3500 Fully Automatic Capsule Filling Machine
Tianjiu Machinery NJP-3500 Fully Automatic Capsule Filling Machine
Product details
Replacement of Supply Tools for Tianjiu NJP-3500 Fully Automatic Capsule Filling Machine
The mold of this equipment consists of three parts: filling, module, and distribution, which can be freely replaced with any set of molds.
1) NJP-3500 Fully AutomaticCapsule Filling MachineReplacement of capsule module:
a. Capsule lower mold: Due to the presence of two positioning pins, when replacing, first loosen the screws and replace with the required lower mold,
Just tighten the screws.
b. Capsule upper mold, loosen the screw to remove the upper mold, install the required upper mold, insert the straightening rod before tightening the screw, adjust it to rotate freely, and tighten the screw.
2) Replacement of the dispensing mechanism of NJP-3500 fully automatic capsule filling machine: vertical fork, horizontal fork, correction seat block, capsule feeding plate, vertical fork, water need to be replaced
The centers of the four positions of the flat fork and correction seat block must be symmetrical and aligned with the centers of the upper and lower mold holes. Use verification E
Great to the center. The movement of the vertical and horizontal forks is consistent, and their travel and starting position can be adjusted by the pull rod. Release the screw
Mother, adjust the length of the pull rod
3) Replacement of filling rod for NJP-3500 fully automatic capsule filling machine: Loosen the pressure plate, remove the filling rod, replace it with the required filling rod, tighten the pressure plate, and then lower it.
4) Replacement of NJP-3500 Automatic Capsule Filling Machine Measuring Disk: Remove the measuring disk, replace it according to the user manual, and calibrate it with a calibration rod
Afterwards, according to the new benchmark, unscrew the filling rod and tighten it according to the depth standard of each workstation. The determination of the reference plane is as follows:
a. After installing the measuring disk, rotate the filling rod to the appropriate position (i.e. when descending, the lower end of the lowest filling rod does not enter the dose disk hole)
b. Rotate the main motor to lower the anode of the grid clamp to the lowest position;
c. Rotate the filling rod to make the lower end face of the rod parallel to the upper surface of the dose disk;
d. Note that the reading on the scale at this time is the new reference plane;
5) NJP-3500 Fully AutomaticCapsule Filling MachineAdjustment of Capsule Tightening: According to different specifications of capsules, when replacing capsules, the length of the capsule locking adjustment rod should be adjusted