Guangzhou Zhengneng Electronic Technology Co., Ltd
Home>Products>Three channel DC resistance tester
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    2nd Floor, No. 81 Dalai South Road, Taihe Town, Baiyun District, Guangzhou City, Guangdong Province, China
Contact Now
Three channel DC resistance tester
Function: DC resistance measurement, transformer DC resistance measurement Resistance range: 0.0u~5000 Resistance resolution: 0.1u Test current: 0.01m
Product details
  ES3080 DC resistance tester, also known as transformer DC resistance tester, is an important instrument mainly used to check whether the connection or mechanical characteristics between windings, windings and leads are good, and whether the resistance between each phase winding is balanced, in order to ensure the safe operation of transformers.
  The transformer DC resistance tester is a new type of instrument used to measure the DC resistance of large capacity transformers. It is designed as a high-precision current stable power supply and testing component. During the testing process, it is controlled by a computer and automatically completes steady-state judgment, data acquisition, data processing, and resistance measurement. Display and print numerical values. This instrument can be used for longitudinal testing of on load voltage regulators with a primary power supply, thus completely saving testing time. It also has the temperature rise testing function of transformer manufacturers. It has the characteristics of simple operation, high accuracy, and anti-interference, and can quickly and accurately measure various types of transformers. The magnetic assist method is to generate a magnetic field by outputting current to the high winding to charge the low winding. With the help of the excitation ampere turns of the high voltage winding, a small current is passed to greatly reduce the inductance of the winding, shorten the measurement time, and achieve the purpose of fast measurement. It should be noted that when using the demagnetization method to measure the DC resistance of low-voltage windings, the current direction of the high and low voltage windings on the same iron core column must be consistent in order to have the effect of demagnetization.
  The ES3080 DC resistance tester consists of a host, test lines, etc., and has functions such as historical data reading, viewing, saving, and printing.
workability DC resistance measurement, transformer DC resistance measurement
DC Resistance 0.0001m Ω~5000 Ω Accuracy: ± 0.2% FS ± 5dgt Minimum Resolution: 0.001m Ω
Output current display 0.01mA~20.000A
Convert resistance Can convert winding material and measured temperature
Three phase unbalance rate Automatically display the unbalance rate of the three-phase winding.
Tap position The tap position can be manually set in the settings interface.
overload protection have
Automatic discharge have
Rated measurement power 1000W
electricitysource AC 220V 10A (50Hz)
body's backlight Adjustable backlight brightness
Measurement method Four line testing
Magnetic assisted testing method High and low voltage output currents, test the resistance at the low voltage end
Short circuit test current 0.2A, 0.5A, 2A, 5A, 10A, 20A (6-speed setting)
Maximum short-circuit current DC 20A±10%
Maximum no-load voltage DC 27V±10%
display mode 7-inch touch color screen
touchscreen correct
Measurement indication Measurement progress display, measurement prompt animation display
Instrument size Length, width, and height: 450mm × 350mm × 180mm
Standard test line length 8 items
UDisk interface Used for connecting USB dedicated interfaces
USBinterface Connect to the computer's dedicated software via USB cable to query and save data
strikeseal Built in thermal printer
Printing paper specifications 57*40mm
Data Storage 500 sets
Data retrieval have
Overflow display Overscale overflow function: "OL" symbol display
Automatic shutdown not have
workconsume Standby:<110W
Measurement: 1000W
naturemeasure Instrument: 27 kg
Test line and wire bag: 5.0kg
Working temperature and humidity -10℃~40℃; Below 80% RH
Storage temperature and humidity -20℃~60℃; Below 70% RH
insulation resistance Above 10M Ω (500V between circuit and casing)
Resistancepress AC 3700V/rms (between circuit and casing)
Suitable for safety regulations IEC61010-1、IEC1010-2-31、IEC61557-1,5、IEC60529(IP54)、 Pollution level 2, CAT III 300V
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!