VIP member
The long diameter nozzle flowmeter and steam flowmeter have TS certification and comply with the special requirements of the municipal supervision
Nozzle flowmeter is a differential pressure generating device for measuring flow rate, which can be used in conjunction with various differential pres
Product details
A nozzle flowmeter is a differential pressure generating device for measuring flow rate, which can be used in conjunction with various differential pressure gauges or transmitters to measure the flow rate of various fluids in pipelines. The standard nozzle throttling device is used in conjunction with differential pressure transmitters to measure the flow rates of liquids, vapors, and gases, and is widely used in sectors such as petroleum, chemical, metallurgical, power, and light industry. Especially suitable for boilers:Main feedwater pipeline, main steam pipeline, reheated steam pipeline
(1) Standard nozzle (ISA1932 nozzle)
·Applicable media: Especially suitable for high temperature and high pressure steam and water, and can also be used for various gases and liquids;
·Nominal caliber: DN50-500mm (DN>500 can also be designed and produced);
·Work pressure: ≤ 42MPa;
·Working temperature: -50 ℃ -650 ℃;
·Pressure tapping method: corner joint (separate ring chamber, integrated flange ring chamber, or direct drilling) for pressure tapping;
·Installation method of nozzle:
Flange (direct drilling and pressure relief), fastener clamping type;
Flange, ring chamber, fastener clamping type;
Welding type clamping component (also used as pressure component);
·Execution standard: IS05167; GB/T2624;
·Accuracy: Complies with standard: ± 1.0%;
·Material: Flanges or clamps: Carbon steel or alloy steel can be selected according to the medium temperature; Stainless steel, etc;
Nozzle: Stainless steel 304; 316, etc.
(2) Long diameter nozzle
·Applicable media: Especially suitable for high temperature and high pressure steam and water, and can also be used for various gases and liquids;
·Nominal caliber: DN50-630mm;
·Work pressure: ≤ 42MPa;
·Working temperature: -50 ℃ -650 ℃;
·Pressure measurement method: radial distance (D-D/2) pressure measurement;
·Installation method of nozzle components: equipped with and welded upstream and downstream pipe sections, and then set pressure holes according to the diameter distance (D-D/2);
·Execution standards: IS05167, GB/T2624;
·Accuracy: Complies with standard: ± 2.0%;
·Material: Carbon steel and alloy steel can be selected for upstream and downstream pipe sections according to the medium temperature; Stainless steel, etc;
Nozzle: Stainless steel 304, 316, etc.
Online inquiry