Gauging Gauge A456C Coating Thickness Gauge
Gauging Gauge A456C Coating Thickness Gauge
The A456C series can be divided into split type and integrated type according to its probe position.
Its integrated models include: A456CFEI1 A456CFBI1 A456CFBI2 A456CFSI1 A456CFTI1 iron matrix, A456CNBI1 non-ferrous matrix, A456CFNEI1 A456CFNBI1 A456CFNSI1 A456CFNTI1 suitable for iron-based and non-ferrous materials.
A456 series is divided into basic category, standard category and advanced category according to its progressiveness.
The part number of the Jig 456 separable coating thickness gauge |
|||
|
basic |
standard |
senior |
Iron based (F) separation type |
A456CFBS |
A456CFSS |
A456CFTS |
Non iron-based (N) separation formula |
A456CNBS |
A456CNSS |
A456CNTS |
Dual purpose separation formula for iron-based (F) and non-ferrous (NF) materials |
A456CFNFBS |
A456CFNFSS |
A456CFNFTS |
The probe used for the separating coating thickness gauge of the Jig 456C is provided separately. |
title
|
Chinese name | range |
T456CF1S | standard probe | 0-1500μ |
T456CF1R |
Right angle probe |
0-1500μ |
T456CF1T | Advanced probe | 0-1500μ |
T456CF2S | F2 probe | 0-5000μ |
T456CF2R | F2 right angle probe | 0-5000μ |
T456CF2T |
F2 Advanced Probe |
0-5000μ |
T456CF12S |
Dual range probe |
T456F1S: 0-1500μ T456F2S: 0-5000μ |
T456CF12R |
Dual range right angle probe | T456F1R: 0-1500μ T456F2R: 0-5000μ |
T456CF3S |
F3 standard probe |
0-13mm |
T456CN1S | Non ferrous standard probe |
0-1500μ |
T456CN1R |
Non ferrous right angle probe | 0-1500μ |
T456CFNF1S |
Dual standard probe |
0-1500μ |
T456CFNF1R | Dual right angle probe | 0-1500μ |
Their functions are as follows: |
|||
function
|
456 Basic
|
456 standard
|
456 Advanced
|
Multiple calibration adjustment options (including factory calibration reset) |
★
|
★
|
★
|
Backlight |
★
|
★
|
★
|
Metric/Imperial |
★
|
★
|
★
|
buzzer |
★
|
★
|
★
|
LED indicator light |
★
|
★
|
★
|
Statistical data (read data number, highest directory Minimum Read Data, Standard Deviation, and Rate of Change |
★
|
★
|
★
|
Infrared data output (HP IR printer) |
★
|
★
|
★
|
Data cable output (printers, computers, and data recorders) |
-
|
★
|
★
|
Read data memory |
-
|
250 readings
Limited to one batch only |
*40,000
|
Average and weighted average |
-
|
★
|
★
|
Single data reading issue |
-
|
★
|
★
|
PC software (including transmission cables) |
-
|
EDTS+
|
EDCS EDTS+
|
Limited thickness |
-
|
★
|
★
|
Clock and alarm clock |
-
|
-
|
★
|
menubar
Screen Function Table |
:
|
All functions of the thickness gauge can be quickly and completely operated through software. CAL (calibration and adjustment of work at hand), DATA (evaluation of batch and limit information, current storage capacity, etc.), STATS (data files and clear statistics), MENU (access to other functions through the main menu). |
main menu |
:
|
Allow selection, printing (for data output), deletion (for deleting individual read data and batch numbers) According to), installation (user function configuration includes Cal method, statistical data, backlight, probe, clock, and alarm, etc.). |
Cal Method Menu |
:
|
Allow selection from a range of unique standard calibration methods, including smooth 2-point, rough surfaces, special substrates, zero compensation, ISO,SSPC, Sweden, Australia, and factories implement standards. |
Statistical Function Table |
:
|
For first-time users, they can also select the statistical values to be displayed from the menu. |
Probe Function Table |
:
|
Select probes for two measurement operations. |
Reset menu |
:
|
Allow users to reset the thickness gauge to adapt to new conditions. |
UK's Easy Gauge Coating Thickness Gauge
Model: A456 New Series
1. Working principle: Iron (F) is measured by electromagnetic induction
2. Non iron (NF) is measured by eddy current method
3. The minimum substrate thickness only needs to be 300 μ m
4. The accuracy is ± 1-3% or ± 2.5 μ m (F1, N1 probes)
5. Multiple language options available, including Chinese, English, Japanese, etc
6. Multiple additional functions include simple statistical functions, backlight, metric and imperial units, etc
7. The measurement speed exceeds 60 readings per minute
8. Alkaline dry batteries can be used continuously for 40 hours
Technical parameters:
Selection of host for split type instrument |
|||
|
Mode B |
Mode S |
Mode T |
Iron-based separation |
A456CFBS |
A456CFSS |
A456CFTS |
Non Iron based Separations |
A456CNBS |
A456CNSS |
A456CNTS |
Dual use split body |
A456CFNFBS |
A456CFNFSS |
A456CFNFTS |
Integrated instrument selection |
||||
|
Mode E |
Mode B |
Mode S |
Mode T |
Iron based (1.5mm range) |
A456CFEI1 |
A456CFBI1 |
A456CFSI1 |
A456CFTI1 |
Iron based (5mm range) |
-- |
A456CFBI2 |
-- |
-- |
Iron based (13mm range) |
-- |
A456CFBI3 |
-- |
-- |
Non iron based |
- |
A456CNBI1 |
-- |
-- |
Iron based and non iron based dual-use |
A456CFNFEI1 |
A456CFNFBI1 |
A456CFNFSI1 |
A456CFNFTI1 |
Technical Parameter
Product Features |
Standard configuration ■ |
|||
mode |
E |
B |
S |
T |
Fast and accurate readings, with 70 data points per minute |
■ |
■ |
■ |
■ |
Repeatability measurement |
■ |
■ |
■ |
■ |
Intuitive menu navigation, available in 25 languages |
■ |
■ |
■ |
■ |
Durable, compact, waterproof and dustproof rating equivalent to IP64 |
■ |
■ |
■ |
■ |
large button |
■ |
■ |
■ |
■ |
USB powered through PC |
■ |
■ |
■ |
■ |
Testing certificate |
■ |
■ |
■ |
■ |
Automatic screen rotation, 0 degrees, 90 degrees, 180 degrees, and 270 degrees |
|
■ |
■ |
■ |
Environmental light sensor, adjustable brightness |
|
■ |
■ |
■ |
Flashlight mode |
|
■ |
■ |
■ |
The latest software for the instrument, ElcoMaster 2.0 software |
|
|
■ |
■ |
data output |
|
■ |
■ |
■ |
USB connection to computer |
|
|
■ |
■ |
Bluetooth sending to computer, PDA or mobile phone |
|
■ |
■ |
■ |
Screen statistics |
|
■ |
■ |
■ |
Test data statistics |
|
■ |
■ |
■ |
Average value x |
|
■ |
■ |
■ |
Standard deviation ó |
|
■ |
■ |
■ |
The highest value hi |
|
■ |
■ |
■ |
Minimum value lo |
|
■ |
■ |
■ |
Coefficient of variation; COV |
|
■ |
■ |
■ |
Gauge index value2 (given value); EIV |
|
■ |
■ |
■ |
Nominal dry film thickness NDFT |
|
|
■ |
■ |
IMO PSPC; |
|
|
■ |
■ |
Limit high and low values, alarm |
|
|
■ |
■ |
Excessive quantity limit |
|
|
■ |
■ |
Quantity ultra-low limit |
|
|
■ |
■ |
ElcoMaster 2.0 software and USB cable |
|
|
■ |
■ |
call the police; Daily (d), intermittent (i) |
|
|
d |
d,i |
Screen protector |
■ |
■ |
■ |
■ |
leather case |
|
■ |
■ |
■ |
Probe form |
|
F, N, FNF |
F, N, FNF |
F, N, FNF |
measuring range |
|
0-30mm |
0-30mm |
0-30mm |
25 language screen calibration navigation |
■ |
■ |
■ |
■ |
Multiple calibration methods |
■ |
■ |
■ |
■ |
Factory, reset factory calibration |
■ |
■ |
■ |
■ |
Two point calibration, smooth and rough surfaces |
■ |
■ |
■ |
■ |
one o'clock; Zero point calibration |
|
■ |
■ |
■ |
Zero point translation 4; ISO19840 standard |
|
|
■ |
■ |
Preset calibration and measurement modes |
|
|
■ |
■ |
ISO, SSPC PA2, Sweden, Australia |
|
|
■ |
■ |
Automatic calibration during rapid calibration |
|
|
■ |
■ |
Calibration memory type; |
g |
g |
gb |
gb |
Batch quantity |
|
|
1 |
999 |
Calibration memory; |
|
|
|
■ |
Measurement alarm exceeding calibration value |
|
|
|
■ |
Calibration Lock |
|
■ |
■ |
■ |
Delete the last data |
|
■ |
■ |
■ |
Instrument memory, measurement data |
|
5 |
750 |
75,000 |
Single batch calibration, sent to PC via ElcoMaster 2.0 |
|
■ |
■ |
■ |
set a limit |
|
■ |
■ |
■ |
Instrument (g) or gauge&batch group (GB) limitations |
|
|
g |
gb |
Date and Time |
|
|
■ |
■ |
Batch types; |
|
|
■ |
■ |
Looking back, cleaning and clearing batch groups |
|
|
■ |
■ |
Copy batch group and calibration settings |
|
|
|
■ |
Greek Alphabet Group Naming |
|
|
|
■ |
Fixed batch size pattern; Batch group online |
|
|
|
■ |
Display Size |
2.4' (6cm) QVGA colour TFT display, 320 x 240 pixels |
battery |
2 x AA dry batteries |
BATTERY LIFE |
Continuous measurements can be taken every second for 24 hours to 24 hours |
Instrument dimensions |
140 x 72 x 45mm |
Instrument weight |
154g with battery included |
operate temperature |
-10 to 50°C |
packing list |
Instrument, wristband, instrument box (T), instrument kit (B, S, T), 1 x screen protector (S, T), 2 x batteries, Instruction manual, USB cable (S, T), ElcoMaster 2.0 software (S, T) |
1. Internet connection required
2. The ISO Index Values are used in the automotive industry to assess the overall quality of coatings; USA Patent Number US7606671B2
FNF patent number UK: GB2306009B; USA: 5886522
Zero drift USA patent number US6243661
5. Battery life is related to battery quality
Compliant standards:
AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091,
ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984,
ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2360, ISO 2808-6A,
ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000,
US Navy NSI 009-32