Dongguan Keshang Measurement Equipment Co., Ltd
Home>Products>The UK's Easy Gauge A456C Coating Thickness Gauge
The UK's Easy Gauge A456C Coating Thickness Gauge
Product Introduction: Elga A456C Coating Thickness Gauge
Product details

Gauging Gauge A456C Coating Thickness Gauge

With improved performance and simplified screen menu options, the Elga A456C coating thickness gauge has become the world's most advanced coating thickness gauge. This leading product has basic, standard, advanced types, integral and a series of separated probes. With a wide range of options, the MiGA456C can meet your specific application requirements. In this section, the Engel A456C will provide a detailed introduction on the following aspects:

Gauging Gauge A456C Coating Thickness Gauge


The A456C series can be divided into split type and integrated type according to its probe position.

Its integrated models include: A456CFEI1 A456CFBI1 A456CFBI2 A456CFSI1 A456CFTI1 iron matrix, A456CNBI1 non-ferrous matrix, A456CFNEI1 A456CFNBI1 A456CFNSI1 A456CFNTI1 suitable for iron-based and non-ferrous materials.

A456 series is divided into basic category, standard category and advanced category according to its progressiveness.

The part number of the Jig 456 separable coating thickness gauge


basic

standard

senior

Iron based (F) separation type

A456CFBS

A456CFSS

A456CFTS

Non iron-based (N) separation formula

A456CNBS

A456CNSS

A456CNTS

Dual purpose separation formula for iron-based (F) and non-ferrous (NF) materials

A456CFNFBS

A456CFNFSS

A456CFNFTS

The probe used for the separating coating thickness gauge of the Jig 456C is provided separately.

title
Chinese name range
T456CF1S standard probe 0-1500μ
T456CF1R

Right angle probe

0-1500μ
T456CF1T Advanced probe 0-1500μ
T456CF2S F2 probe 0-5000μ
T456CF2R F2 right angle probe 0-5000μ
T456CF2T

F2 Advanced Probe

0-5000μ
T456CF12S

Dual range probe

T456F1S: 0-1500μ
T456F2S: 0-5000μ
T456CF12R
Dual range right angle probe T456F1R: 0-1500μ
T456F2R: 0-5000μ
T456CF3S

F3 standard probe

0-13mm
T456CN1S Non ferrous standard probe

0-1500μ

T456CN1R

Non ferrous right angle probe 0-1500μ
T456CFNF1S

Dual standard probe

0-1500μ
T456CFNF1R Dual right angle probe 0-1500μ

Their functions are as follows:

function
456 Basic
456 standard
456 Advanced
Multiple calibration adjustment options (including factory calibration reset)
Backlight
Metric/Imperial
buzzer
LED indicator light
Statistical data (read data number, highest directory
Minimum Read Data, Standard Deviation, and Rate of Change
Infrared data output (HP IR printer)
Data cable output (printers, computers, and data recorders)
-
Read data memory
-
250 readings
Limited to one batch only
*40,000
Average and weighted average
-
Single data reading issue
-
PC software (including transmission cables)
-
EDTS+
EDCS EDTS+
Limited thickness
-
Clock and alarm clock
-
-

menubar

Screen Function Table
All functions of the thickness gauge can be quickly and completely operated through software. CAL (calibration and adjustment of work at hand), DATA (evaluation of batch and limit information, current storage capacity, etc.), STATS (data files and clear statistics), MENU (access to other functions through the main menu).
main menu
Allow selection, printing (for data output), deletion (for deleting individual read data and batch numbers)
According to), installation (user function configuration includes Cal method, statistical data, backlight, probe, clock, and alarm, etc.).
Cal Method Menu
Allow selection from a range of unique standard calibration methods, including smooth 2-point, rough surfaces, special substrates, zero compensation, ISO,SSPC, Sweden, Australia, and factories implement standards.
Statistical Function Table
For first-time users, they can also select the statistical values to be displayed from the menu.
Probe Function Table
Select probes for two measurement operations.
Reset menu
Allow users to reset the thickness gauge to adapt to new conditions.

UK's Easy Gauge Coating Thickness Gauge
Model: A456 New Series
1. Working principle: Iron (F) is measured by electromagnetic induction
2. Non iron (NF) is measured by eddy current method
3. The minimum substrate thickness only needs to be 300 μ m
4. The accuracy is ± 1-3% or ± 2.5 μ m (F1, N1 probes)
5. Multiple language options available, including Chinese, English, Japanese, etc
6. Multiple additional functions include simple statistical functions, backlight, metric and imperial units, etc
7. The measurement speed exceeds 60 readings per minute
8. Alkaline dry batteries can be used continuously for 40 hours

Technical parameters:

Selection of host for split type instrument


Mode B

Mode S

Mode T

Iron-based separation

A456CFBS

A456CFSS

A456CFTS

Non Iron based Separations

A456CNBS

A456CNSS

A456CNTS

Dual use split body

A456CFNFBS

A456CFNFSS

A456CFNFTS


Integrated instrument selection


Mode E

Mode B

Mode S

Mode T

Iron based (1.5mm range)

A456CFEI1

A456CFBI1

A456CFSI1

A456CFTI1

Iron based (5mm range)

--

A456CFBI2

--

--

Iron based (13mm range)

--

A456CFBI3

--

--

Non iron based

-

A456CNBI1

--

--

Iron based and non iron based dual-use

A456CFNFEI1

A456CFNFBI1

A456CFNFSI1

A456CFNFTI1

Technical Parameter


Product Features

Standard configuration ■

mode

E

B

S

T

Fast and accurate readings, with 70 data points per minute

Repeatability measurement

Intuitive menu navigation, available in 25 languages

Durable, compact, waterproof and dustproof rating equivalent to IP64

large button

USB powered through PC

Testing certificate

Automatic screen rotation, 0 degrees, 90 degrees, 180 degrees, and 270 degrees


Environmental light sensor, adjustable brightness


Flashlight mode


The latest software for the instrument, ElcoMaster 2.0 software



data output


USB connection to computer



Bluetooth sending to computer, PDA or mobile phone


Screen statistics


Test data statistics


Average value x


Standard deviation ó


The highest value hi


Minimum value lo


Coefficient of variation; COV


Gauge index value2 (given value); EIV


Nominal dry film thickness NDFT



IMO PSPC;
%>NDFT, %>90



Limit high and low values, alarm



Excessive quantity limit



Quantity ultra-low limit



ElcoMaster 2.0 software and USB cable



call the police; Daily (d), intermittent (i)



d

d,i

Screen protector

leather case


Probe form
Iron based (F), Non iron based (N), Dual use (FNF) 3


F, N, FNF

F, N, FNF

F, N, FNF

measuring range


0-30mm

0-30mm

0-30mm

25 language screen calibration navigation

Multiple calibration methods

Factory, reset factory calibration

Two point calibration, smooth and rough surfaces

one o'clock; Zero point calibration


Zero point translation 4; ISO19840 standard



Preset calibration and measurement modes



ISO, SSPC PA2, Sweden, Australia



Automatic calibration during rapid calibration



Calibration memory type;
Instrument (g) or Instrument&Batch Group (GB)

g

g

gb

gb

Batch quantity



1

999

Calibration memory;
3 users programmable memory




Measurement alarm exceeding calibration value




Calibration Lock


Delete the last data


Instrument memory, measurement data


5

750

75,000

Single batch calibration, sent to PC via ElcoMaster 2.0


set a limit
User preset listening and hearing alarms


Instrument (g) or gauge&batch group (GB) limitations



g

gb

Date and Time



Batch types;
Normal, counted average, IMO PSPC



Looking back, cleaning and clearing batch groups



Copy batch group and calibration settings




Greek Alphabet Group Naming




Fixed batch size pattern; Batch group online






Display Size

2.4' (6cm) QVGA colour TFT display, 320 x 240 pixels

battery

2 x AA dry batteries

BATTERY LIFE

Continuous measurements can be taken every second for 24 hours to 24 hours

Instrument dimensions

140 x 72 x 45mm

Instrument weight

154g with battery included

operate temperature

-10 to 50°C

packing list

Instrument, wristband, instrument box (T), instrument kit (B, S, T), 1 x screen protector (S, T), 2 x batteries,

Instruction manual, USB cable (S, T), ElcoMaster 2.0 software (S, T)

1. Internet connection required
2. The ISO Index Values are used in the automotive industry to assess the overall quality of coatings; USA Patent Number US7606671B2
FNF patent number UK: GB2306009B; USA: 5886522
Zero drift USA patent number US6243661
5. Battery life is related to battery quality

Compliant standards:
AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091,
ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984,
ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2360, ISO 2808-6A,
ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000,
US Navy NSI 009-32

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!