Technical parameters:
|
model |
SC-SZ-408E |
SC-SZ-800E |
|
Studio SizeW×H×D(mm) |
600850×800 |
10001000×800 |
|
External dimensionsW×H×D(mm) |
1100×1710×1370 |
15001860×1370 |
|
temperature range |
-70℃~+100℃(150℃)(A:25℃,B:0℃,C:-20℃,D:-40℃,E:-50℃,F:-60℃,G:-70℃) |
|
|
Humidity range |
20%~98%R.H.(10%~98%R.H. 5%---98%R.H.For special selection conditions) |
|
|
Temperature and humidity analysis accuracy/Uniformity |
0.1℃,0.1%R.H.±1.0℃,±3.0%R.T. |
|
|
Temperature and humidity control accuracy/fluctuation |
±1.0℃,, 2.0%R.H./±0.5℃,±2.0%R.H. |
|
|
Heating up/Cooling time |
make an appointment3.0℃/Minutes, approximately1.0℃/Minutes (decreasing every minute)2---10℃The above are special selection conditions) |
|
|
Internal and external materials |
The outer box isSUS304#Stainless steel plate matte treatment or electrostatic spray painting |
|
|
Insulation material |
High temperature resistant high-density polyurethane rigid foam insulator material |
|
|
Cooling system |
Air-cooled type/Single stage compressor (-)20℃), gas, water-cooled type/Double end compressor(-40℃~-70℃) |
|
|
Protector |
Non fuse switch, compressor overload protection switch, refrigerant high and low voltage protection switch, over humidity and over temperature protection switch, fuse, fault warning system |
|
|
accessory |
Recorder (optional), observation window50mmTest holes, interior lighting fixtures, partitions, dry and wet bulb gauze |
|
|
Vibration table |
Optional according to user requirements, detailed technical parameters can be found in the Mechanical Edition Catalog (Vibration System)18--20Page) |
|
|
controller |
South Korea“TEMI”Or JapanOYOCard selection |
|
|
compressor |
French "Taikang" brand |
|
|
power supply |
3Φ380V AC±10% 50/60Hz |
|