Shenzhen Yijie Instrument Co., Ltd
Home>Products>Temperature and humidity transmitter TS13/14
Temperature and humidity transmitter TS13/14
▪ Small size, exquisite and sturdy appearance, easy to install.
Product details

Temperature and humidity transmitterTS13/14

Taishio Wall_Duct Type Temperature & Humidity Transmitter - TS13_14

characteristic

▪ Small size, exquisite and sturdy appearance, easy to install.

▪ Economical price and high cost-effectiveness.

▪ High tech sensing components with high precision and excellent long-term stability.

application

HVAC process monitoring/air conditioning/environmental ventilation control.

Air conditioning monitoring for office buildings/residences/hospitals.

Building automation environment monitoring.

Technical Overview

input
Type of input signal Capacitive humidity sensor and PT1000 Ω
measuring range Temperature: 0-50 ℃; Humidity: 0~100%
Suggested scope of work Temperature: 15-35 ℃; Humidity: 20~80%
output
Output Signal 4~20mA; 0-10V
Signal connection method Two line, three line
Accuracy (25 ℃)
Temperature/humidity ±0.3℃+0.002℃x /±3% RH(20∼80 %)
Temperature influence 0.2%RH/℃
Load impedance Two wire current:< (V-10)/0.02<500 Ω Three wire current:<200 Ω Three wire voltage:> 10KΩ
Output calibration [ZERO] adjustment range Zero point and 10% of full scale
Reaction time T90 (temperature at+25 ℃) <20S
environment
Measurement medium air
Ambient Temperature 0-50℃
storage temperature 25~+ 60℃
CE certification EN 61326-1:2006,EN61326-2-2:2006
Emissions EN55011:2009 / A1:2010
Immunity IEC 61000-4-2:2008

IEC61000-4-3:2006 / A1:2007 / A2:2010

IEC61000-4-8:2009

National Electric Code
Working power supply Two wire type: 11-35VDC/Three wire type: 15-35VDC and 19-29VAC
Consumption current Two wire DC: 41mA Three wire DC: 56mA Three wire AC: 150mA
Electrical connection Two wire type: 3P terminal block/Three wire type: 4P terminal block
Installation and fixation
Installation method Indoor wall mounted installation/duct type flange base installation
protection grade IP54 (Sensor: IP20)
electrical protection Reverse protection, overvoltage, short circuit
Shell material PC fire rating (PC-110)
weight TS13: 132 grams/TS14:157 grams

13

TS□
Installation method function output Working power supply scope of work
13: Indoor type

14: Duct type

A: Temperature/humidity output

H: Humidity output

T: Temperature output

1: 4-20mA (two-wire)

3: 4-20mA (three wire type)

6: 0-10V (three wire type)

1: 11~35VDC (two-wire)

3: 15-35VDC

Compared to 19~29VAC (three wire type)

30:0-50 ℃

00:00~100% RH

(Humidity output)

14

Share to:
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!