TSI Respirator Suitability/Fit Tester (TSI8048) complies with OSHA, CSA, HSE, and ANSI standards and is suitable for all fit respirators, including: 9
Product details
detailed description:

TSI Respirator Suitability/Fit Tester (TSI8048)Product Introduction

PortaCountThe suitability tester is a testing instrument that provides a consistent and objective testing experience, suitable for includingN95Filter masks and various types of respirators, and the instrument also hasFitCheckNew features such as mode and suitability testing animation tutorials help users better and faster verify the suitability of respirators.
FitCheck
The mode displays real-time changes in the suitability of the respirator throughout the entire wearing and adjustment process, helping users select the appropriate respirator and achieve optimal suitability faster.
Animated tutorial videos can guide employees to correctly perform each inspection training, provide a consistent inspection experience, and reduce personnel costs.
PortaCount
It is a reliable suitability testing instrument that improves employee safety and production efficiency for you.


TSI Respirator Suitability/Fit Tester (TSI8048)Product Features:



comply withOSHATheCSATheHSEandANSIStandard, applicable to all confidential information
Respirators, including:9599100TheFFP1TheFFP2andFFP3Filter type respirator
The suitability factor for measurement can be greater than10,000
Using tiny particles in ambient air to calculate the suitability factor of respirators
useFitPro UltraSoftware automatically performs suitability testing
real-timeFitCheckThe mode can train new users and exclude those who have failedSexual testing

The mask sampling adapter kit can be used for suitability testing on employees' personal respirators

Through software, it can be found on the suitability test report orIDPrint suitability test card on the card



Technical Specifications:


Suitable factor range:1~10,000AboveN95The face mask is1~200
Typical suitability factor accuracy:Reading of±10%
Respiratory mask for suitability testing
Elastic full face cover
Elastic half face mask
NIOSH 100
Series filter mask
NIOSH 99
Series filter mask
NIOSH 95
Series filter mask
FFP1
TheFFP2TheFFP3Series of respirators
Suitable factor measurement: directly measure the suitable factor(Cout/Cin*
Size:12 cm x 27 cm x 24 cm4.83 in. x 10.5 in. x 9.46 in.
Weight: Single device3.2 kg7.0 lb.)Including standard accessories and instrument boxes6.9 kg15.35 lb.

power supply100 ~ 250VAC,50-60Hz
Traffic: Sampling traffic350 cm3/min, total traffic1000 cm3/min(nominal value)
Temperature Range Operating Temperature0 ~ 38°C32 ~ 100°F
Storage temperature-40 ~ 50°C-40 ~ 122°F
Working fluid:99.5%Reagent grade isopropanol
Running time after fully charged At21°C70°F)At temperature, it is 6 hour
Instrument box: size(HWD25.4 cm x 52.1 cm x 39.4 cm
(10.0 in. x 20.5 in. x 15.5 in.)
pass/Failed to set up User defined:0 ~ 10,000