TR-108S economical COD rapid analyzer
Detection principle:
The TR-108S economical COD rapid analyzer from Tongao brand uses a closed digestion tube for closed digestion. In a strong acidic solution, a special oxidant containing a certain amount of potassium dichromate is used to digest the water sample at a constant temperature of 165 ℃ under the action of a catalyst, so that the reducing substances in the water are oxidized. The total absorbance of the unreduced Cr6+and reduced Cr3+or the absorbance of the reduced Cr3+are measured at different wavelengths.
Technical Specifications:
| measurement method | HJ/T399-2007 |
| Determination of Chemical Oxygen Demand in Water Quality - Rapid Digestion Spectrometric Method | Measurement range |
| 0-2000mg/L (segmented measurement) | limit of detection |
| 5 mg/L | Dissolving temperature |
| 165℃,15min | Anti chlorine interference |
| 1000mg/L | resolution |
| 0.001mg/L | accuracy |
| COD value>50mg/L, indication error not exceeding 5% | repetitiveness |
| The relative standard deviation shall not exceed 3% | Optical stability |
| ≤ 0.001A/20 minutes | Instrument dimensions |
| 270mm*220mm*95mm | Instrument power supply |
| AC(220V±10%),50Hz | ambient temperature |
| 5~40℃ | ambient humidity |
| ≤ 85% non condensing | Instrument weight |
Host<1.4kg, disintegrator 1.3kg
Function and Features:
1. Using EPA approved methods that comply with HJ/T399-2007 standards, the measurement is accurate and effective.
2. Adopting imported high brightness and long-life cold light source with excellent optical performance, the light source has a lifespan of up to 100000 hours.
3. 5-inch large LCD screen with full Chinese display, direct data reading, simple and time-saving operation.
4. Dissolve colorimetric integrated, no need to replace tube, simple and fast measurement, no safety hazards.
5. Can save 80 standard curves and 1800 measured values (date, time, parameters, test data).
6. The memory standard working curve, and users can also calibrate the curve as needed.
7. It has the function of curve coverage interference to prevent accidental operation of covering curves.
8. It has data storage function and data power-off protection function, making it convenient to query historical measurement data and prevent data loss.
9. The digestion instrument adopts intelligent PID temperature control technology and a dual anti overheating protection system, ensuring safe and uniform heating with fast speed. Used for the digestion of COD, total phosphorus, total nitrogen and other projects.
Standard equipment list:
| Standard configuration list of TR-108S COD rapid analyzer | serial number | name | quantity | serial number | name |
| 1 | quantity | Measurement host | 8 | 1 unit | power cord |
| 2 | 2 pieces | 6-hole intelligent digestion instrument | 9 | 1 unit | Instruction Manual |
| 3 | 1 copy | Dissolve the protective cover | 10 | 1 piece | Certificate of Conformity/Warranty Card |
| 4 | 1 copy | COD reagent | 11 | ||
| 5 | 1 set | Dissolving colorimetric integrated tube | 12 | ||
| 6 | 10 pieces | Dissolving tube cooling rack | 13 | ||
| 7 | 1 piece | Color tube cleaning cloth | 14 |
1 pieceClick to view other COD analyzers: 2.one