TR-108 COD rapid analyzer
Detection principle:
The TR-108 COD analyzer from Tongao brand uses a closed digestion tube for closed digestion. In a strong acidic solution, a special oxidant containing a certain amount of potassium dichromate is used to digest the water sample at a constant temperature of 165 ℃ under the action of a catalyst, so that the reducing substances in the water are oxidized. The total absorbance of the unreduced Cr6+and reduced Cr3+in the water is measured at different wavelengths, or the absorbance of the reduced Cr3+is measured.
Technical parameters:
measuring method | HJ/T399-2007 "Determination of Chemical Oxygen Demand in Water Quality - Rapid Digestion Spectrometric Method" |
Measurement range | 0-10000 mg/L (segmented measurement) |
limit of detection | 5mg/ L |
Dissolving temperature | 165℃,15min |
Anti chlorine interference | 1000mg/L |
resolution | 0.001mg/L |
accuracy | COD value>50mg/L, indication error not exceeding 5% |
repeatability | The relative standard deviation shall not exceed 3% |
Optical stability | ≤ 0.001A/20 minutes |
Instrument dimensions | 310mm*230mm*150mm |
Instrument power supply | AC(220V±10%),50Hz |
ambient temperature | 5~40℃ |
ambient humidity | ≤ 85% non condensing |
Instrument weight | Host<3kg, disintegrator 6kg |
Product features:
1. Developed and designed according to HJ/T399-2007 standard, the measurement results are accurate and effective.
2. Adopting imported high brightness and long-life cold light source with excellent optical performance, the light source has a lifespan of up to 100000 hours.
3. Large LCD screen with full Chinese display, direct data reading, simple and time-saving operation.
4. Dissolve colorimetric integrated, no need to replace tube, simple and fast measurement, no safety hazards.
5. Can save 80 standard curves and 1800 measured values (date, time, parameters, test data).
6. The memory standard working curve, and users can also calibrate the curve as needed.
7. One click factory reset allows for quick recovery in case of curve loss due to misoperation.
8. It has the function of curve coverage interference to prevent accidental operation of covering curves.
9. It has data storage function and data power-off protection function, making it convenient to query historical measurement data and prevent data loss.
10. Equipped with a USB interface, data can be transferred to the computer for permanent storage.
11. It has a printing function and can print the measured values immediately or query the historical records for printing.
12. The digestion instrument adopts intelligent PID temperature control technology and a dual anti overheating protection system, ensuring safe and uniform heating with fast speed. Used for the digestion of COD, total phosphorus, total nitrogen and other projects.
Standard equipment list:
TR-108 COD analyzer standard configuration list
Serial number | Name | quantity | Serial Number | Name | number |
1 | Printing type testing host | 1 unit | 8 | Color tube cleaning cloth | 1 piece |
2 | 16 hole intelligent digestion instrument | 1 unit | 9 | power cord | 2 pieces |
3 | Dissolve the protective cover | 1 piece | 10 | USB data cable | 1 piece |
4 | COD determination reagent | 1 set | 11 | Online CD | 1 sheet |
5 | standard solution | 1 set | 12 | Operation flowchart | 1 copy |
6 | Dissolving colorimetric integrated tube | 10 pieces | 13 | operation instructions | 1 copy |
7 | Colorimetric tube cooling rack | 1 piece | 14 | Certificate of Conformity/Warranty Card | 1 copy |
Qualifications related to COD rapid analyzer:
Click to view other COD analyzers:
TR-108S economical COD rapid analyzer
TR-108S portable COD rapid analyzer