1scope of application
TIME2190ultrasonic thickness gaugeusePulse reflection typeMeasurement principle,Suitable for various materialsMeasurement of thickness.The instrument emits through a probeUltrasonic waves at a constant speedmaterialinternalperformspreadAnd initsbottom surfaceObtain reflectionReceive after the wave.
This itemThe instrument can accurately measure various sheets and processed parts,Widely used in petroleum, chemical, metallurgical, shipbuilding, aviation, and aerospace industriesBoilerWaiting for various fields.
IIBasic principles
TIME2190 Ultrasonic Thickness GaugeThe principle is similar to that of optical wave measurement. The ultrasonic pulse emitted by the probe entersTested objectafterIn the objectinternalspreadWhenArrival materialsofReflected back to the probe at the interface, through precisecountUltrasonic waves in materialsofspreadThe sound path can be inferredThe thickness of the tested material.
3、 Characteristics of the instrument
-Can display A-scan waveform, facilitating echo analysis and measurement of complex workpieces;
-It has multiple measurement methods and can be set to blank to shield aftershocks or clutter;
-The instrument can be adapted to various types of probes, suitable for single and double crystals;
-Penetrating coating measurement, capable of displaying coating thickness;
-Resolution of 0.001, 0.01, 0.1 millimeters is optional in any mode (or 0.0001, 0.001, 0.01)
Inches optional);
-Gain adjustment range 40-99dB;
-Adjustable voltage and variable pulse width square wave pulse generator;
-Equipped with single value B-scan display function;
-Equipped with alarm function, the upper and lower limits of the alarm can be freely set;
-Display methods for difference and size values;
-Can store up to 500000 measurement values and waveforms;
-Users can activate the fast measurement mode up to 20 times per second;
4、 Each part and name of the instrument (as shown in the following figure)
4.1 Power Supply
Note: For probes that distinguish between transmitting and receiving ends, such as TSTU32, they should be inserted into the transmitting and receiving sockets.
The instrument is powered by 3 AA batteries and the battery level will be indicated on the screen. The Coulomb meter is used for power measurement, so it defaults to a fully charged new battery when there is a power outage. Twist open the back cover with a coin or key to replace the battery.
4.2measuring range
probe Type |
Measurement range (steel) |
Indication error |
Usage mode |
5MHz twin crystal narrow pulse probe |
1.2~225.0mm 3.0~100.0mm |
H<10mm,±0.05mm; H≥10mm,±(0.01+ 0.5%H)mm |
standard Echo - Echo |
5MHz single crystal contact probe |
5.0~225.00mm 5.0~100.00mm |
H<10mm,±0.05 mm; H≥10mm,±(0.01+ 0.5%H) mm |
standard Echo - Echo |
2MHz dual crystal probe: TSTU32 |
3.0~300.00mm |
H<10mm,±0.1 mm; H≥10mm,±(0.01+1%H) mm |
standard |
1MHz single crystal contact probe |
10.0~500.00mm |
H<10mm,±0.1 mm; H≥10mm,±(0.01+1%H) mm |
standard |
15MHz single crystal delay block probe |
3.0mm~20.0mm 0.25mm~10.0mm |
H<10mm,±0.05 mm; H≥10mm,±(0.01+ 0.5%H) mm |
Interface - Echo Echo - Echo |
- Display resolution: 0.001mm, 0.01mm, or 0.1mm optional
- Speed adjustment range: 508 m/s to 18699m/s
- Repeatability: ± 0.1(Comply with JJF1126)
- Probe parameters: optional 1M single crystal 5M10M15M single crystal 20M22MHz probe
- Display: Color TFT LCD display, 320x240 pixels, 5-digit display, with backlight
- Measurement function:High precision measuring tools suitable for measuring good conductors of metals, plastics, ceramics, glass, and any other ultrasonic waves. Conventional measurement, small thickness capture, large thickness capture, difference, upper and lower limit LED alarm
- Special material measurement: gain adjustment range: 20-99dB; shielding strip: adjustable for initial pulse bottom wave, interface wave bottom wave, and echo echo modes. Slope: adjustable to 11. The above three functions can be used in combination to measure various special materials, such as molybdenum containing stainless steel (316, 317, etc.), fiberglass, cast iron with extremely poor spheroidization rate, gray iron, etc.
- Set Lock: Lock calibration data, etc
- Pulse Generator: Adjustable Square Wave Pulse Generator
- I/O port: Bidirectional serial RS-232
- Emission voltage: 60V, 110V, 150V, 200V optional
- Transmitting pulse width: varies with probe frequency
- Gain range: 40-99dB, 1dB step
- Frequency range: 0.5 MHz to 20MHz
- Measurement rate: standard (4Hz), fast (20Hz)
- Probe settings: 10 sets of fixed probe settings and 22 sets of custom probe settings
- Data storage: 500 data files, each capable of storing 1000 measurement values and waveforms
- Operating environment temperature: 0 ℃~40 ℃
- Power supply: Three No. 5 dry batteries
- Working language:Chinese, English
- Power consumption: Operating current not exceeding 250mA (WiFi off, low brightness, at 4.5V)
- Dimensions: 187mm × 87mm × 43mm
- Shell: impact resistant, dust-proof, splash proof, compliant with IP65
- Weight: Approximately 360g
- Applicable standards and specifications: Q/HD SDF0001-2014 ultrasonic thickness gauge
JJF 1126-2004ultrasonic thickness gaugeCalibration standards
GB/T 6587 General Specification for Electronic Measuring Instruments
4、 Standard configuration
1host 1 unit
2. 5MHz twin crystalprobe 1 unit
3. 1 imported 5MHz single crystal probe (optional)
4Couplant 1 bottle
5、 Optional accessories
1standard test block
2. 1MHz single crystal contact probe
3. TSTU32 cast iron probe
4. 5MHz single crystal contact probe
5. 15MHz Single Crystal Band Delay Block Probe
6. High temperature probe ZW5P