Structural diagram of the new ZW7 electric high-voltage vacuum circuit breaker in Chengdu

Structural diagram of the new ZW7 electric operated high-voltage vacuum circuit breaker in Chengdu

The new ZW7-40.5 vacuum circuit breaker is smaller in size than the old ZW7, reduces space for easy installation, is lightweight and easy to transport, has a simple structure, fewer moving parts, and is completely suitable for pole mounted single bar connection.

ZW32 structural characteristics
1. The circuit breaker adopts a three-phase pillar structure, which has the characteristics of stable and reliable breaking performance, no combustion and explosion hazards, maintenance free, small size, light weight, and long service life.
2. The circuit breaker adopts a fully enclosed structure with good sealing performance, which helps to improve moisture-proof and anti condensation performance, especially suitable for use in cold or humid areas.
3. The three-phase pillars and current transformers adopt imported outdoor epoxy resin solid insulation, or indoor epoxy resin wrapped with organic silicon rubber solid insulation; It has the characteristics of high and low temperature resistance, UV resistance, and aging resistance.
4. Circuit breakers can be equipped with two-phase or three-phase current transformers for overcurrent or short-circuit protection, and can also provide current acquisition signals to intelligent controllers; According to user requirements, measuring current transformers can be installed.
5. The circuit breaker can be equipped with a three-phase interlocking isolation switch, which has a visible fracture when the isolation switch is in the open state, and has an anti misoperation interlock device with the circuit breaker body. The circuit breaker can only be operated when the isolation switch is fully closed or fully opened. Can be connected to lightning arrester post insulators for easy maintenance.

Technical Parameter

Main technical parameters of circuit breaker

Serial number

Project

unit

Numerical value

1

rated voltage

kV

40.5

2

Rated current

A

1250/1600/2000/2500

3

Rated frequency

Hz

50 or 60

4

Power frequency withstand voltage for 1 minute (wet) (dry)

Interphase, ground/fracture

kV

80 95/95

5

Lightning impulse withstand current (peak value)

Interphase, ground/fracture

kV

185

6

Rated short circuit breaking current

kA

25/31.5

7

Rated short-circuit closing current (peak)

kA

63/80

8

Rated peak withstand current

kA

63/80

9

4S short-time withstand current

kA

25/31.5

10

Rated operating cycle

Split -0.1s - Split -3s - Split -6s - Split -60s Recovery

11

Rated short-circuit current breaking times

order

30

12

mechanical life

order

10000

13

Institutional control voltage

V

AC/DC220

14

Secondary circuit 1-minute power frequency withstand voltage

KV

2

Main mechanical parameters of circuit breakers

Serial number

Parameter

unit

Data

1

clearance between open contacts

mm

18±1

2

Contact overtravel

mm

4±0.5

3

opening speed

m/s

1.4-1.8

4

closing speed

m/s

0.4-0.8

5

Contact closing bounce time

ms

≤5

6

Center distance between phases

mm

710±2

7

Three phase opening and closing asynchrony

ms

≤2

8

Resistance of each phase conductive circuit

μΩ

<80

9

close time

ms

≤100

10

Opening time

ms

≤50

11

weight

Kg

About 800

35KV Outdoor High Voltage Vacuum Circuit Breakerzone of application

Zhejiang Province, Jiangsu Province, Anhui Province, Shanghai City, Shandong Province, Hebei Province, Henan Province, Beijing City, Tianjin City, Shandong Province, Liaoning Province, Heilongjiang Province, Jilin Province, Inner Mongolia Autonomous Region, Shanxi Province, Shaanxi Province, Gansu Province, Autonomous Region, Xizang Autonomous Region, Qinghai Province, Yunnan Province, Guangxi Autonomous Region, Sichuan Province, Guizhou Province, Chongqing City, Hubei Province, Hunan Province, Jiangxi Province, Guangdong Province and other regions.

35KV Outdoor High Voltage Vacuum Circuit Breakerpurchasing process

1. Purchasing department, inform the product specifications, models, and quantities

2. Communicate with the technical department to confirm the drawings and verify the parameters

3. The Ministry of Commerce drafts contracts based on technical agreements and places orders for production

4. The production department produces according to the drawing parameters of the technical department and the order table of the business department

5. Shipping Department Customer Delivery Address and Method - Shipping

6. Receipt follow-up: Salespeople promptly follow up on customer receipt and provide feedback to the company

7. Follow up on customer satisfaction with product usage in the office, conduct market research to better serve customers and the market

Structural diagram of the new ZW7 electric high-voltage vacuum circuit breaker in Chengdu

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!