The air outlet has an adjustable fence to adjust the angle, which can more evenly distribute the air volume;
Model Description:
Example: HWF-80-10-3025-12 (industrial hot fan, electric heating power of 10KW, power supply of 3-phase 380V, motor of 180W, type 1 chassis)
Attention:
The operating environment of the motor is: temperature -10 ℃~80 ℃, humidity ≤ 85%, height 1000m, and the air must be free of flammable substances.
model |
HWF-80/230-3-3025-11 |
HWF-80/230-10/15/20-3025/055-12 |
HWF-80/230-30/40/60-3025/055-21 |
HWF-80/230-80/100-3055-31 |
Power supply 50Hz |
Three phase 380V |
Three phase 380V |
Three phase 380V |
Three phase 380V |
Electric heating power |
3kW |
10/15/20kW |
2x(15/20)/3x20kW |
4x20/5x20kW |
Motor Power |
250W |
250W/550W |
250/550W |
550W |
Specification of air outlet |
400x410 |
400x410 |
400x410 |
400x410 |
Air volume |
33m3/min |
33m3/min /44m3/min |
33m3/min /44m3/min |
44m3/min |
Weight (approximately) |
30/kg |
30/42kg |
30/42kg |
42kg |
Can be configured with other power sources suitable for voltage or frequency
Hot fan matching temperature control box
The standard temperature control box adopts international brand electrical main controls (such as frequency converter, PID temperature controller, etc.), SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of PID temperature controller is ± 0.5%.
The economical temperature control box adopts international brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. are not equipped with frequency converters, but with motor protectors. The precision of PID temperature controller is ± 0.5%;
The practical temperature control box adopts domestic brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of PID temperature controller is ± 0.5% Not equipped with a frequency converter, but equipped with a motor protector.
Model description of matching temperature control box:
Example: TCB-S3-11 (with standard temperature control box, equipped with frequency converter, electric heating power of 3KW, type 1 chassis)
model |
TCB-S/E/P3-11 |
TCB-S/E/P10-12 |
TCB-S/E/P15-13 |
TCB-S/E/P20-14 |
TCB-S/E/P20-15 |
Adapt to the power of the hot air fan |
3φ3kW |
3φ10kW |
3φ15kW |
3φ20kW |
3φ30kW |
model |
TCB-S/E/P45-16 |
TCB-S/E/P60-17 |
TCB-S/E/P90-18 |
TCB-S/E/P120-19 |
|
Adapt to the power of the hot air fan |
3φ45kW |
3φ60kW |
3φ90kW |
3φ120kW |
Schematic diagram of Baofeng hot fanpicture
Size diagram of Baofeng hot fan
model |
A |
B |
A1×B1 (Air outlet size) |
C |
D |
H |
L |
L1 |
HWF-80/230-3-1018-11 HWF-80/230-10/15/20-3018/025/055-12 |
550 |
560 |
400×410 |
180 |
280(310) |
1060 |
600 |
220 |
HWF-80/230-30/40/60-3025/055-21 |
550 |
560 |
400×410 |
350 |
280(310) |
1060 |
800 |
390 |
HWF-80/230-80/100-3055-31 |
550 |
560 |
400×410 |
500 |
280/300(310/330) |
1060 |
950 |
540 |
The dimensions of 230oC type D are within () unit: mm
Fan holder is an optional item (fan holder is not included when purchasing the device, but can be provided separately if needed)
Not equipped with power cord and temperature compensation wire.