Shanghai Equan Pump Industry Co., Ltd
Home>Products>Stainless steel non clogging submersible sewage pump
Stainless steel non clogging submersible sewage pump
The stainless steel non clogging submersible sewage pump adopts a large channel anti clogging hydraulic component design, greatly improving the abilit
Product details

product overview
Stainless steel non clogging submersible sewage pump is a new type of submersible sewage pump made of precision manufactured stainless steel material. The product has undergone acid washing and polishing treatment, and has a beautiful appearance. It has the characteristics of ordinary submersible sewage pumps and is superior to WQ submersible sewage pumps. It is resistant to use in general corrosive environments.It has the characteristics of significant energy-saving effect, anti winding, no blockage, automatic installation and automatic control. It has a unique effect in the discharge of solid particles and long fiber waste. This seriesSewage pumpBy adopting a unique impeller structure and a new type of mechanical seal, it can effectively transport media containing solid matter and long fibers. Compared with traditional impellers, the impeller of this pump adopts a single channel or double channel form, which is similar to a curved pipe with the same cross-sectional size and has very good flow characteristics. Coupled with a reasonable volute chamber, the pump has high efficiency and the impeller has undergone dynamic and static balance tests, making the pump operate without vibration.
The hydraulic performance of this pump is advanced and mature. After testing, all performance indicators of the product have reached the relevant standards and regulations. After its launch on the market, the product has been welcomed and praised by a large number of users for its unique efficacy, reliable performance, and stable quality.

scope of application
Stainless steel non clogging submersible sewage pump is suitable for the discharge of severely polluted wastewater in factories and commercial areas, sewage discharge stations in residential areas, urban sewage treatment plant drainage systems, civil air defense system drainage stations, water supply equipment in water plants, sewage discharge in hospitals and hotels, municipal engineering construction sites, mining supporting machinery, rural biogas digesters, farmland irrigation and other industries. It can also be used for conveying granular sewage and pollutants, as well as for clean water and weakly corrosive media.

Conditions of Use
1. This series of sewage pumps is suitable for rated voltage of 380V and power frequency of 50Hz
2. The temperature of the medium should not exceed 40 degrees Celsius, the density of the medium should be ≤ 1150kg/m3, and the pH value should be between 5-9;
3. The altitude shall not exceed 1000 meters;
4. The annual viscosity of the conveying medium shall not exceed 1000CP;
5. The product must be completely submerged in water during operation, but the diving depth must not exceed 10m;
6. The product material is mainly cast iron and cannot be used in highly corrosive or corrosive media;
Attention: Before selecting or installing the pump, it is necessary to ensure that the actual usage conditions of the pump comply with the above terms to ensure the correct use of the product!

Product Features
1. Adopting a double blade impeller structure greatly improves the ability of pollutants to pass through;
2. The mechanical seal adopts a new type of friction pair and operates in the oil chamber for a long time;
3. The overall structure is compact, small in size, low in noise, and has significant energy-saving effects. It is easy to maintain and convenient for users to replace;
4. The automatic control cabinet can automatically control the pump's over movement and stop according to the required liquid level changes, without the need for dedicated personnel to supervise, making it extremely convenient to use;
5. Installation methods can be provided according to user needs, which greatly facilitates installation and maintenance. People do not need to enter the sewage pit for this purpose;
6. Can be used within the design scope while ensuring that the motor does not overload;

Product Selection

For example: 50WQ (QW) P15-30-3
50- Discharge diameter (mm)
WQP Fixed Stainless Steel Submersible Sewage Pump
QWP Mobile Stainless Steel Submersible Sewage Discharge
15- Flow rate (m3/h)
30 Head (m)
3- Power consumption (KW)

model

caliber
mm

internet traffic
m3/h

lift
m

power
KW

rotational speed
r/min

efficiency
%

25WQ(QW)P8-22-1.1

25

8

22

1.1

2825

38.5

32WQ(QW)P12-15-1.1

32

12

15

1.1

2825

40

40WQ(QW)P15-15-1.5

40

15

15

1.5

2840

45.1

40WQ(QW)P15-30-2.2

40

15

30

2.2

2840

48

50WQ(QW)P20-7-0.75

50

20

7

0.75

1390

54

50WQ(QW)P10-10-0.75

50

10

10

0.75

1390

56

50WQ(QW)P20-15-1.5

50

20

15

1.5

2840

55

50WQ(QW)P15-25-2.2

50

15

25

2.2

2840

56

50WQ(QW)P18-30-3

50

18

30

3

2880

58

50WQ(QW)P25-32-5.5

50

25

32

5.5

2900

53

50WQ(QW)P20-40-7.5

50

20

40

7.5

2900

55

65WQ(QW)P25-15-2.2

65

25

15

2.2

2840

52

65WQ(QW)P37-13-3

65

37

13

3

2880

55

65WQ(QW)P25-30-4

65

25

30

4

2890

58

65WQ(QW)P30-40-7.5

65

30

40

7.5

2900

56

65WQ(QW)P35-50-11

65

35

50

11

2930

60

65WQ(QW)P35-60-15

65

35

60

15

2930

63

80WQ(QW)P40-7-2.2

80

40

7

2.2

1420

52

80WQ(QW)P43-13-3

80

43

13

3

2880

50

80WQ(QW)P40-15-4

80

40

15

4

2890

57

80WQ(QW)P65-25-7.5

80

65

25

7.5

2900

56

100WQ(QW)P80-10-4

100

80

10

4

1440

62

100WQ(QW)P110-10-5.5

100

110

10

5.5

1440

66

100WQ(QW)P100-15-7.5

100

100

15

7.5

1440

67

100WQ(QW)P85-20-7.5

100

85

20

7.5

1440

68

100WQ(QW)P100-25-11

100

100

25

11

1460

65

100WQ(QW)P100-30-15

100

100

30

15

1460

66

100WQ(QW)P100-35-18.5

100

100

35

18.5

1470

65

125WQ(QW)P130-15-11

125

130

15

11

1460

62

125WQ(QW)P130-20-15

125

130

20

15

1460

63

150WQ(QW)P145-9-7.5

150

145

9

7.5

1440

63

150WQ(QW)P180-15-15

150

180

15

15

1460

65

150WQ(QW)P180-20-18.5

150

180

20

18.5

1470

75

150WQ(QW)P180-25-22

150

180

25

22

1470

76

150WQ(QW)P130-30-22

150

130

30

22

1470

75

150WQ(QW)P180-30-30

150

180

30

30

1470

73

150WQ(QW)P200-30-37

150

200

30

37

1480

70

200WQ(QW)P300-7-11

200

300

7

11

970

73

200WQ(QW)P250-11-15

200

250

11

15

970

74

200WQ(QW)P400-10-22

200

400

10

22

1470

76

200WQ(QW)P400-13-30

200

400

13

30

1470

73

200WQ(QW)P250-15-18.5

200

250

15

18.5

1470

72

200WQ(QW)P300-15-22

200

300

15

22

1470

73

200WQ(QW)P250-22-30

200

250

22

30

1470

71

200WQ(QW)P350-25-37

200

350

25

37

1980

75

200WQ(QW)P400-30-45

200

400

30

45

1480

70

250WQ(QW)P600-9-30

250

600

9

30

980

74

250WQ(QW)P600-12-37

250

600

12

37

1480

78

250WQ(QW)P600-15-45

250

600

15

45

1480

75

250WQ(QW)P600-20-55

250

600

20

55

1480

73

250WQ(QW)P600-25-75

250

600

25

75

1480

73

250WQ(QW)P800-12-45

250

800

12

45

980

76

300WQ(QW)P500-15-45

300

500

15

45

980

70

300WQ(QW)P800-15-55

300

800

15

55

980

73

300WQ(QW)P600-20-55

300

600

20

55

980

75

300WQ(QW)P800-20-75

300

800

20

75

980

78

300WQ(QW)P950-20-90

300

950

20

90

980

80

300WQ(QW)P1000-25-110

300

1000

25

110

980

82

350WQ(QW)P1100-10-55

350

1100

10

55

980

84.5

350WQ(QW)P1500-15-90

350

1500

15

90

980

82.5

350WQ(QW)P1200-18-90

350

1200

18

90

980

83.1

350WQ(QW)P1100-28-132

350

1100

28

132

740

83.2

350WQ(QW)P1000-36-160

350

1000

36

160

740

78.5

350WQ(QW)P1500-10-75

400

1500

10

75

980

82.1

400WQ(QW)P2000-15-132

400

2000

15

132

740

85.5

400WQ(QW)P1700-22-160

400

1700

22

160

740

82.1

400WQ(QW)P1500-26-160

400

1500

26

160

740

83.5

400WQ(QW)P1700-30-200

400

1700

30

200

740

83.5

400WQ(QW)P1800-32-250

400

1800

32

250

740

82.1

Applicable occasions of the product:
1. The discharge of severely polluted wastewater from factories and businesses.
2. Urban sewage treatment plant drainage system.
3. Sewage drainage stations in residential areas.
4. Civil air defense system drainage station.
5. Wastewater discharge from hospitals and hotels.
6. Stainless steel non clogging submersible sewage pump for municipal engineering and construction sites.
7. Exploration and mining supporting equipment.
8. Rural biogas digesters for farmland irrigation.
9. The water supply system of a water plant.

fault analysis

Reason for malfunction

cause analysis processing method
Pump flow or head decrease 1. Pump reversal 1. Turn off the main power supply of the control box and replace any two-phase power lines.
2. The conveying head is too high. 2. Check: a. Whether the selected pump model is correct.
b、 Is the size of the outlet pipe correct.
3. The suction medium goes through a bypass. 3. Check if the valve is closed tightly, and then fully load test the pump.
4. The water outlet pipe is leaking. 4. Identify the leak and make corrections accordingly.
5. The outlet pipe may be partially blocked by sediment 5. Inspect pipelines, clean or replace with new ones.
6. The pump is partially blocked. 6. Lift the pump surge, and if the pump is placed inside the filter screen, it also needs to be inspected and cleaned
7. Impeller/base wear. 7. Lift the pump to adjust the clearance or replace parts.
The pump does not produce liquid after operation 1、 a、 Open and close the valve several times in succession.
1. Air blockage. b、 Start and stop the pump several times, with a gap of 2-3 minutes between each restart
c、 According to different installation methods, check if an air release valve needs to be installed
2. Check the water discharge valve. 2、 a、 If the valve is in the closed state, it should be opened.
  b、 If the installation is reversed, it should be reversed again.
3. Pump reversal. 3. Refer to 1. (1)
The pump starts and stops too frequently 1. The distance set by the float switch is too short. 1. Reset the float switch to extend the running time.
2. The check valve is malfunctioning and cannot check back, causing the liquid to flow back into the sewage tank. 2. Check and repair.
The sewage pump stops and malfunctions 1. Floating ball opening, pavilion stop 'malfunction'. 1. Check and replace if necessary.
2. The float on the float is stuck in the 'working' position 2. If necessary, the position can be changed.
After the pump is started, the circuit breaker/overload device trips open 1. Low voltage. 1、 a、 Check the voltage of the control box. If the voltage is too low, it cannot be used temporarily. b、 If the cable is too long and causes excessive voltage drop, the cable should be shortened as much as possible and thicker cables should be selected appropriately.
2. The voltage is too high. 2. Install a transformer and plug the voltage hole into the specified range.
3. Electric sarcasm wiring is incorrect 3. Check the cable color codes and connector numbers in the control box and inspect the wiring
4. Has mud accumulated at the bottom of the snail shell? It's sediment. 4. Clean the pump and sewage tank, refer to the relevant sections in the installation instructions.
The pump cannot be started, the fuse is blown or the circuit breaker is tripped 1. Float malfunction. 1. Check if the bypass float switch can start the pump. If so, the float switch should be checked.
2. Winding, joint or cable open circuit. 2. Check with an ohmmeter. If it is proven to be a circuit, check the winding, terminals, and cables.
3. The pump is blocked 3. Cut off the power, remove the pump from the sewage tank, clear obstacles, and try it out before resetting.
The pump cannot start, but the fuse is not broken or the overload protector does not trip 1. No electricity. 1. Check if the control box has power.
2. Windings, cables, connectors, or control switches are disconnected. 2. Check the connectors and windings of cables and motors.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!