1、 Overview: Tin plated flexible copper stranded wire for electricians (TJRX1)It has the advantages of high conductivity, good anti-corrosion performance, and wide range of applications. Material: Tin plated copper. This product is suitable for connecting motor and electrical equipment components.
2、 Product standard: GB 321 Priority Numbers and Priority Number Systems GB 2900.10 Electrical Terminology - Wires and Cables GB 3048.4 Test Method for DC Resistance of Conductive Core of Wires and Cables GB 3953 Electrical Round Copper Wire GB 4006 Winding Wire Cylindrical Coil GB 4909.1 General Principles for Bare Wire Test Methods GB 4909.2 Test Methods for Bare Wires - Dimensional Measurement GB 4909.3 Test Methods for Bare Wires - Tensile Test GB 4910 Tin Plated Round Copper Wire GB 12970.2 Electrical Flexible Copper Stranded Wire Part 2: Flexible Copper Stranded Wire GB 12970.3 Electrical Flexible Copper Stranded Wire Part 3: Flexible Copper Antennas GB 12970.4 Electrical Flexible Copper Stranded Wire Part 4: Copper Brush Wire
This standard specifies the product varieties, structures, and technical requirements of soft copper stranded wires for electrical purposes. This standard is applicable to flexible copper stranded wires used for wiring electrical equipment and electronic appliances or components. Soft copper stranded wire should not only comply with the requirements of this standard, but also meet the requirements of GB 12970.1. 3、 Specification and model: 1. The models of soft copper stranded wires are shown in Table 1 Table 1
model |
name |
TJR 1 TJR 2 TJR 3 TJRX 1 TJRX 2 TJRX 3 |
Type 1 soft copper stranded wire Type 2 soft copper stranded wire Type 3 soft copper stranded wire Type 1 tinned flexible copper stranded wire Type 2 Tin Plated Soft Copper Stranded Wire Type 3 Tin Plated Soft Copper Stranded Wire
|
2. The specifications of the twisted wire for soft copper walls and iron walls are shown in Table 2. Table 2
model |
name |
TJR 1 TJR 2 TJR 3 TJRX 1 TJRX 2 TJRX 3 |
0.10~1000 2.5~63 0.025~500 0.1~2.5 2.5~63 0.025~500
|
1. The model of soft copper stranded wire is shown in Table 1
Table 1
|
model |
Main purpose |
TRJ |
Connecting wires for mobile or semi mobile electrical equipment (such as switches, electric heaters, etc.). |
TRJ-1 |
Connecting wires for mobile or semi mobile electrical equipment (such as switches, electric heaters, etc.). |
TRJ-2 |
Internal connection line of wireless equipment |
TRJ-3 |
Require softer electrical equipment lead wires and grounding wires. |
|
2. The structure and performance parameters of soft copper stranded wire shall comply with the provisions of Tables 2-5
TRJ Type Table 2 |
|
Nominal cross-section mm2 |
Number of shares x quantity x longitude mm |
DC resistance at 20 ℃ Ω/km |
Reference outer diameter mm |
Reference weight kg/km |
Manufacturing length m |
10 |
7xx7x0.52 |
1.83 |
4.7 |
98 |
2000 |
16 |
7x7x0.64 |
1.26 |
5.8 |
144 |
2000 |
25 |
7x12x0.62 |
0.695 |
7.7 |
239 |
2000 |
35 |
7x19x0.58 |
0.512 |
8.9 |
322 |
1000 |
50 |
7x19x0.68 |
0.375 |
10.2 |
444 |
1000 |
70 |
7x27x0.68 |
0.262 |
12.6 |
631 |
1000 |
95 |
7x37x0.68 |
0.195 |
14.3 |
865 |
500 |
120 |
7x37x0.76 |
0.153 |
16.0 |
1080 |
500 |
150 |
7x48x0.74 |
0.134 |
18.1 |
1328 |
500 |
185 |
7x61x0.74 |
0.098 |
20.0 |
1668 |
500 |
240 |
7x61x0.85 |
0.081 |
23.0 |
2227 |
250 |
|
TRJ-1 Type Table 3 |
Nominal cross-section mm2 |
Number of shares x quantity x longitude mm |
DC resistance at 20 ℃ Ω/km |
Reference outer diameter mm |
Reference weight kg/km |
Manufacturing length m |
25 |
7x14x0.58 |
0.695 |
7.7 |
238 |
200 |
120 |
12x27x0.68 |
0.153 |
15.9 |
1080 |
500 |
150 |
19x14x0.85 |
0.120 |
18.7 |
1380 |
500 |
185 |
27x12x0.85 |
0.098 |
21.7 |
1690 |
500 |
240 |
37x12x0.85 |
0.072 |
24.7 |
2320 |
250 |
|
TRJ-2 Table 4 |
Nominal cross-section mm2 |
Root count X-ray meridian mm |
DC resistance at 20 ℃ Ω/km |
Reference outer diameter mm |
Reference weight kg/km |
Manufacturing length m |
0.12 |
7x0.15 |
145 |
0.45 |
1.12 |
2000 |
0.30 |
16x0.15 |
63.6 |
0.71 |
2.53 |
2000 |
0.50 |
16x0.20 |
36.0 |
0.94 |
4.5 |
1000 |
0.60 |
7x0.32 |
32.1 |
1.0 |
5.1 |
1000 |
0.75 |
19x0.23 |
26.0 |
1.15 |
7.3 |
2000 |
1.00 |
19x0.26 |
17.6 |
1.3 |
9.33 |
4000 |
|
TRJ-3 Type Table 5 |
Nominal cross-section mm2 |
Number of shares x quantity x longitude mm |
DC resistance at 20 ℃ Ω/km |
Reference outer diameter mm |
Reference weight kg/km |
Manufacturing length m |
0.15 |
5x0.2 |
114.68 |
0.60 |
1.4 |
2000 |
0.2 |
7x0.2 |
81.84 |
0.65 |
2.0 |
2000 |
0.3 |
10x0.2 |
57.34 |
0.85 |
2.9 |
2000 |
0.4 |
12x0.2 |
47.75 |
0.90 |
3.5 |
2000 |
1.2 |
38x0.2 |
15.10 |
1.60 |
11.0 |
1000 |
2 |
7x10x0.2 |
8.2 |
2.5 |
20.0 |
1000 |
3 |
7x14x0.2 |
5.85 |
2.8 |
28.0 |
500 |
4 |
7x18x0.2 |
4.65 |
3.2 |
36.0 |
3000 |
5 |
7x23x0.2 |
3.54 |
3.6 |
46.0 |
3000 |
6 |
7x27x0.2 |
3.03 |
3.8 |
55.0 |
3000 |
10 |
7x46x0.2 |
1.78 |
5.0 |
93.0 |
3000 |
16 |
7x72x0.2 |
1.14 |
6.0 |
146.0 |
2000 |
25 |
7x114x0.2 |
0.71 |
7.5 |
231.0 |
2000 |
|
|