Product Overview:
Single flange liquid level transmitterWith advanced design principles, complete variety and specifications, and easy installation and use, this series of products is suitable for the continuous improvement and development of domestic automation level. In addition to being small and exquisite in design, it also introduces products withHARTThe intelligent function of fieldbus protocol is suitable for liquid level measurement of high temperature, high pressure, strong corrosion and other media.
Product features:
Range and zero point are continuously adjustable externally
High precision, good stability, two-wire system
Positive migration reachable500%Negative transfer can be achieved600%
Adjustable damping and overvoltage resistance
Solid state sensor design
No mechanical movable parts, low maintenance volume
Lightweight and compact
Unified structure and strong interchangeability across the entire series
The membrane material in contact with the medium is optional
Unilateral overpressure resistance
Low pressure cast aluminum alloy shell
Technical parameters:
Measurement range:50~10MPa(Segmented selection)
Measurement accuracy:1Digital signal: ±0.05level
2Analog signal: ±0.075、 ±0.2、 ±0.5
Trace range (≤1.5kpa):±0.2
Output signal:4~20mADC
Load resistance:0~600Ω(24VDCPower supply)
Transmission distance:>1000m
Stability: ±0.2%F.S/Year (△)t=28℃, maximum static pressure6.9MPa, Range1:1Under certain conditions)
Zero point and range:External continuous adjustable
Positive migration:500%
Negative transfer:600%
Static pressure effect:1Zero point error (can be eliminated under static pressure)
Static pressure from0~13.7MPa, ±0.2%/6.9MPa
Static pressure exceeds13.7MPa, ±0.5%/6.9MPa
2Range error: ±0.25%/6.9MPa
Environmental temperature impact/28℃:
1Range ratio1:1~10:1:≤±0.2%
2Trace range (≤)1.5KPa):±0.5%
Power supply impact:<0.005%V
Vibration impact:15~2000HzTest in any axial direction < ±0.1%F.S
Installation location impact: maximum zero point impact250PaCorrectable, without range impact
RF interference impact:20~1000MHz,1Beyond meters, ±0.1%F.S
Insulation strength and reverse protection: between the terminal block and the housing50HZ、100VNo arcing occurred for one minute,24VDCReverse connection without damage
Working power supply:12~45VDC
Working temperature:-20~85℃
Environmental temperature:-40~+50℃
Relative humidity:0~100%
Instrument weight: approximately3KG
Instrument height:190mm
Cable threading hole:M20×1.5perhapsNPT1/2'
Pressure connection:1Pressure hole:1/4NPTInternal cone tube thread
2Pressure screw:M10×1.5, spacing41.3
3Pressure connection joint
Isolation membrane:316LHa ShiC-276Monel, Tantalum
Exhaust valve/Drain valve:316LHa ShiC-276Or Monel optional
SensorsoType sealing ring: Nitrile rubber, PTFE, metal sealing ring
Sensor filling fluid: silicone oil, fluorine oil
Instrument casing and coating: low copper aluminum alloy, anodized, sprayed polyurethane
Protection level:IP65
Explosion proof grade:1Intrinsic safety type:Exia II Cb6Ga
2Explosion proof type:Exd II Cb6Gb
Product Usage:
Single flange liquid level transmitterMainly used in petroleum, steel, metallurgy, oil fields, chemical industry, thermal power plants, light industry, sewage treatment, flow measurement, etc.