Dalian Yilite Analytical Instrument Co., Ltd
Home>Products>Shodex chromatographic column
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 2-2, Xuezi Street, Qixianling, Dalian City, Liaoning Province
Contact Now
Shodex chromatographic column
Shodex chromatographic column
Product details

Gel filtration chromatographic column (GFC, with aqueous solution as mobile phase)

stationary phase

substrate

pHrange

application

OHpak SBseries

Polyhydroxymethyl methacrylate

3-10

Can be used for separating water-soluble molecules and determining molecular weight distribution;
Suitable for analysis under various mobile phase conditions, such as alkaline conditions.

Protein KWseries

silicone rubber

3-7.5

Compared to polymer columns,KWSeries columns are more suitable for analyzing substances with molecular weights ranging from several thousand to several million, such as proteins.



Regular GFC Column Ordering Information


classification

OEM NO

product description

Inner diameter(mm

Length(mm

GFC

F6429100

SB-802 HQ 8um

8.0

300

GFC

F6429101

SB-802.5 HQ

8.0

300

6um

GFC

F6429102

8.0

300

SB-803 HQ 6um

GFC

F6429103

8.0

300

SB-804 HQ 10um

GFC

F6429104

8.0

300

SB-805 HQ 13um

GFC

F6429105

8.0

300

SB-806 HQ 13um

GFC

F6429106

8.0

300

SB-806M HQ

GFC

F6429108

8.0

300

SB-807 HQ

GFC

F6989000

8.0

300

KW-802.5

GFC

F6989103

8.0

300

KW-803

GFC

F6989104

8.0

300



KW-804


Regular GFC Column Ordering Information

Sealing solvent

stationary phase

characteristic

THFKF-800

seriesThe most commonGPC

Column, with a wide range of applications

chloroformK-800

seriesThe application scope is second only toTHF

solvent

DMFKD-800

series

Suitable for analyzing polar polymers such as melamine, polyacrylonitrile, polyvinylpyrrolidone, polyimide

HFIPHFIP-800

seriesCan analyze engineering plastics such as polyamide at room temperature(nylon)

And polyethylene terephthalate

THF

LF-804Porous permeability with good linear calibration curveGPC



Column, with wide pore size distribution, eliminates the shoulder peak easily produced by mixed gel column, and there are many solvents for replacement

Sugar column

The analysis of general sugars can adopt separation modes such as coordination exchange, volume exclusion, ion exclusion, and normal phase.SUGAR

series

Sugar separation combines different separation modes, such as coordination exchange, volume exclusion, ion exclusion, and positive phase.

Suitable for separating sugars and sugar alcohols.Asahipak NH2P

series

Using the normal phase mode to achieve sugar separation is suitable for separating monosaccharides, oligosaccharides, and sugar alcohols.SUGAR KS

series

Combining volume exclusion and coordination exchange modes to achieve carbohydrate separation. The exclusion limits of each column are different, so the appropriate column can be selected based on the molecular weight of monosaccharides, disaccharides, oligosaccharides, and polysaccharides.

USPpak MN-431Analyze mannitol according to the United States Pharmacopeia(USP,23




Version)

Ionic exchange chromatography column hydrophobic chromatography column

stationary phase

Application scope

Sample molecular weightIEC

seriesSuitable for proteins, peptidesDNARNA4Analysis of oligonucleotides, etc. have

Types of ion exchange functional groups.

high molecular weightAsahipak ES

seriesThere is weak anion exchange(DEAE)Exchange with weak cations(CM)Two types, andIEC

The separation characteristics of the series are slightly different.

high molecular weight

AXpak WA-624Weak anion exchange column, with an ion exchange capacity of1.2meq/g

Dry gel, suitable for anion exchange analysis of nucleic acids, such as nucleotides.

low molecular weight

CXpak P-421S

Suitable for analysis of amino acids and amino sugars.

low molecular weight

HICPH-814

Hydrophobic chromatography, analyzed under mild conditions, is not prone to biodegradation and is suitable for analyzing biological samples such as proteins.



high molecular weight

Ion chromatography column

Ion chromatography is divided into two methods: with suppressors and without suppressors. Shodex columns for analyzing anions and cations are available for both inhibitory and non inhibitory systems. We also provide columns for practical post column derivatization analysis of transition metal ions and rare earth metal ions. Please select the column based on the analysis requirements and ion types.

NI-424Analyze anions using the inhibitor free method.NI-424correctI-524AThe high-efficiency column can also separate chloride ions and phosphoric acid, usingI-524A

It cannot be achieved.

I-524A

Y-521Analyze cations using the inhibitor free method.Y-521Suitable for separating various alkyl amines.YK-421

Can simultaneously separate single and divalent cations.

YK-421

SI-90

Analyze anions using suppressors. Proficient in analyzing chloride ions, removing foreign organic acids, and not affected by the peak of the carbonate system, it is suitable for analyzing anions in various samples and requires a suppressor in the ion chromatography system.

SI-50

SI-52

SI-91

T-521T-521Suitable for analyzing transition metal ions;R-621

Suitable for analyzing rare earth metal ions. The post column derivatization method has high sensitivity for measuring metal ions.



R-621

Polymer carrier normal phase and reverse phase chromatography column



Shodex's polymer carrier chromatography column has a longer lifespan and a wider pH range compared to silica carrier chromatography columns.

Organic acid specific column



Generally, organic acid analysis can be achieved through ion exclusion, ion exchange, and reverse phase modes. The Shodex organic acid specific column RSpak KC-811 introduces ion exclusion, volume exclusion, and reverse phase composite modes to achieve the separation of multiple organic acids. When using KC-811, KC-G is generally used as a protective column for samples, and KC-LG is recommended for samples with high impurities.

Shodex chiral column



The Shodex ORpak and Shodex AFpak ABA-894 series produced by Shodex use fillers with coordination groups, which can identify various optical isomers. There are three types of coordination groups: α, β, and γ cyclodextrin derivatives (CD), L-amino acid derivatives, and bovine serum albumin.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!