Shimadzu water-soluble SEC (GFC) liquid chromatography columnproduct description
| SB-800 HQ | Polymer matrix filler water-soluble SEC (GFC) analysis column ● Can be used for the determination of a wide range of molecular weights The solvent can be replaced with DMF (except for SB-802 HQ and SB-807 HQ chromatography columns), which can analyze polar polymers SB-804 HQ and SB-805 HQ can be used to determine the average molecular weight distribution of gelatin (Japanese PAGI Test Method 10th edition) |
| SB-807 HQ | A chromatographic column suitable for analyzing high molecular weight substances with strong water solubility To suppress the cleavage of molecular chains, large particle size fillers are used |
| SB400 | Sensitivity is three to four times that of the KW-800 series SB401-4E can analyze small molecules with a molecular weight less than 1000 |
| product number | NAME | plate number (TP/column) |
exclusion limit (Pullulan) |
Particle size | Zui Large Aperture | Specifications I.D.×L |
Storage solvent |
|---|---|---|---|---|---|---|---|
| F6429100 | OHpak SB-802 HQ | ≥12,000 | 4,000 | 8μm | 100Å | 8.0×300mm | 0.02% NaN3aq. |
| F6429101 | OHpak SB-802.5 HQ | ≥16,000 | 10,000 | 6μm | 200Å | 8.0×300mm | 0.02% NaN3aq. |
| F6429102 | OHpak SB-803 HQ | ≥16,000 | 100,000 | 6μm | 800Å | 8.0×300mm | 0.02% NaN3aq. |
| F6429103 | OHpak SB-804 HQ | ≥16,000 | 1,000,000 | 10μm | 2,000Å | 8.0×300mm | 0.02% NaN3aq. |
| F6429104 | OHpak SB-805 HQ | ≥12,000 | (4,000,000)※ | 13μm | 7,000Å | 8.0×300mm | 0.02% NaN3aq. |
| F6429105 | OHpak SB-806 HQ | ≥12,000 | (20,000,000)※ | 13μm | 15,000Å | 8.0×300mm | 0.02% NaN3aq. |
| F6429106 | OHpak SB-806M HQ | ≥12,000 | (20,000,000)※ | 13μm | 15,000Å | 8.0×300mm | 0.02% NaN3aq. |
| F6409430 | OHpak SB-G | (Protective pillar) | - | 10μm | - | 6.0×50mm | 0.02% NaN3aq. |
Matrix: Polyhydroxymethyl methacrylate Suitable pH range: pH 3-10 ※ () Estimated value
SB-806M HQ is a mixed packing chromatography column suitable for analyzing samples with a wide molecular weight distribution
| product number | NAME | plate number (TP/column) |
exclusion limit (Pullulan) |
Particle size | Zui Large Aperture | Specifications I.D.×L |
Storage solvent |
|---|---|---|---|---|---|---|---|
| F6429108 | OHpak SB-807 HQ | ≥1,500 | (500,000,000)※ | 35μm | 30,000 | 8.0×300mm | H2O |
| F6709431 | OHpak SB-807G | (Protective pillar) | - | 35μm | - | 8.0×50mm | H2O |
Matrix: Polyhydroxymethyl methacrylate Suitable pH range: pH 3-10 ※ () Estimated value
| product number | NAME | plate number (TP/column) |
exclusion limit (Pullulan) |
Particle size | Zui Large Aperture | Specifications I.D.×L |
Storage solvent |
|---|---|---|---|---|---|---|---|
| F6429111 | SB401-4E | ≥5,000 | 1,000 | 10μm | 40Å | 4.6×250mm | H2O |
| F6429112 | SB402.5-4E | ≥20,000 | 10,000 | 6μm | 200Å | 4.6×250mm | H2O |
| F6429113 | SB403-4E | ≥20,000 | 100,000 | 6μm | 800Å | 4.6×250mm | H2O |
| F6429114 | SB404-4E | ≥20,000 | 1,000,000 | 7μm | 2,000Å | 4.6×250mm | H2O |
| F6709432 | SB400G-4A | (Protective pillar) | - | 7μm | - | 4.6×10mm | H2O |
Matrix: Polyhydroxymethyl methacrylate Suitable pH range: pH 3-10
| NAME | Resistant to organic solvents (maximum%) | ||
|---|---|---|---|
| Methanol | Acetonitrile | N-N-dimethylformamide | |
| SB401-4E | 0 | 10 | 0 |
| SB-802 HQ | 0 | 0 | 0 |
| SB-802.5 HQ, SB-803 HQ SB402.5-4E, SB403-4E |
100 | 75 | 100 |
| SB-804 HQ~SB-806M HQ, SB404-4E |
75 | 75 | 100 |
| SB-G, SB400G-4A | 75 | 75 | 100 |
| SB-807 HQ, SB-807G | 30 | 30 | 0 |
<Attention>
The SB-800 series corresponds to a preparation column (SB-2000 series) with a maximum applicable concentration of 50% for methanol, acetonitrile, and DMF. (SB-2002 and SB-802- samples,
The above solvents cannot be used
If customization is required, please contact Shodex or the nearest distributor.