Senmat Instrument (Beijing) Co., Ltd
Home>Products>San En Shi Fog Meter
San En Shi Fog Meter
San'enshi Mist Meter Model: YH1210 Product Introduction: YH1210 Mist Meter can easily achieve ASTM D1003 non compensating method, ISO 13468 compensati
Product details

San En Shihaze meter

model:YH1210

Product Introduction:

YH1210Mist meter can be easily implementedASTM D1003Non compensatory lawISO 13468Compensation method, full transmittance and haze testing, open sample chamber can be tested vertically or horizontally to adapt to more tested samples.YH1210The haze meter adoptsPDArray detector, meeting the requirementsCIE V(λ)2Visual response of degree,Compensation method measurement can achieve high-precision and repeatable measurement of transmittance and haze data.

YH1210Technical advantages of haze meter

1Double standardISO & ASTM
Can meet the testing standard requirements of different users and comply with the standards:ASTM D1003/1044,ISO 13468ISO 14782GB/T 2410,JJF 1303-2011CIE 15.2GB/T 3978,ASTM E308JIS K7105JIS K7361JIS K 7136

2Equipped with compensation port for more accurate measurement data

satisfyASTM D1003Non compensatory lawISO 13468Compensation method, full transmittance and haze testing, providing more accurate test results

3.Easy to operate, faster and more accurate measurement

YH1210The haze meter is equipped with a large-sized touch operation screen, which is easy and convenient to operate. It adoptsPDArray detector, meeting the requirementsCIE V(λ)2Visual response can achieve high-precision and repeatable measurements of transmittance and haze.USBData output device that can be integrated with laboratory systems.

4Equipped with compensation port for more accurate measurement data

satisfyASTM D1003Non compensatory lawISO 13468Compensation method, full transmittance and haze testing, providing more accurate test results

5Convenient measurement and wide sample adaptability

Open measurement area, capable of vertical and horizontal testing, suitable for more tested samples

6Quality management software

Provide powerful software for measuring and analyzing haze and transmittance, suitable for quality monitoring and tabular management of haze and transmittance data in various industries. Manage users inPCComputerized dataization, comparing differences in haze and transmittance, generating test report forms to facilitate customer customization and management work.

application

YH1210Haze meters are widely used in industries such as glass processing, plastic processing, film, display screen processing, and packaging for detecting transmittance and haze.

San En Shihaze meterYH1210Technical Parameter

PRODUCT MODEL

YH1210haze meter

Illumination

Transmission:0/D(Parallel light illumination, diffuse reflection reception)
Compliant with standards:ASTM D1003/1044,ISO 13468ISO 14782GB/T 2410,JJF 1303-2011CIE 15.2GB/T 3978,ASTM E308JIS K7105JIS K7361JIS K 7136

characteristic

The instrument can be easily implementedASTM D1003Non compensatory lawISO 13468Compensation method, full transmittance and haze testing.
Open measurement area, capable of vertical and horizontal testing.
It is widely used in industries such as glass processing, plastic processing, film, display screen processing, and packaging for transparency and haze detection.

Integral sphere size

Φ154mm

lighting source

400~700nmcombinationLEDlight source

a sensor

PDArray detector, meeting the requirementsCIE V(λ)2Visual response of degree

Transmittance measurement range

0~100%

measuring aperture

Φ20mm/Φ15mm/Φ8mm/Φ4mm(Choose a single caliber)

Sample size

Thickness less than105mm

Other chromaticity indicators

Haze ratio(ASTM D1003/1044,ISO 13468), transmittanceT(ISO), transmittanceT(ASTM)

Observer's perspective

Observing light source

D65,A,C

display

qualified/Unqualified results

Time

make an appointment1.5s

Mist resolution

0.01unit

Mist repeatability

Φ20mmcaliber,Less than0.1Within (after preheating and calibration of the instrument),At intervals5sThe test haze is approximately40The standard haze film30Sub standard deviation)

Inter station difference

Φ20mmcaliber,less than0.4Within (after preheating and calibration of the instrument),At intervals5sTest the standard deviation between the haze standard haze film and the reference value

size

longXwideXtall=487X260X298mm

weight

make an appointment8.0kg

Power supply mode

direct-current24V,3APower adapter for power supply

Lighting source lifespan

5Year over300Ten thousand measurements

display

TFTtrue color7inchCapacitive touch screen

interface

USBPrint serial port

Store data

Standard sample1000Article, sample20000strip

language

Simplified Chinese, Traditional Chinese, English

Operating temperature range

0~40℃32~104°F

Storage Temperature Range

-20~50℃-4~122°F

Standard accessory

Power adapter, manual, quality management software(download)Data cable0Calibration box, measuring caliber

Optional Accessories

Micro printer, testing fixture, standard haze film, foot switch

Note:

If there are any changes, no further notice will be given

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!