1、 Product Usage
This device is mainly used for flame retardant performance testing of seat belts, safety nets, and protective clothing.
2、 Product applicable standards
GB/T6096-2009Test Method for Seat Belts
GB/T 5455Vertical flame retardant test for textiles
GB 5725-2009 "Safety Net"
IIISpecification
1Power consumption of the mobile motor of the burner: 10W;
2. Igniter timing: freely set from 0 to 99.99 seconds (standard uses 12 seconds);
3. Continuation time and flame retardant time timer: 0-99.99 seconds, accuracy: ± 0.01 seconds;
4. Flame height measuring device: ruler height 40mm;
5. Gas used: propane, butane, or liquefied petroleum gas.
4、 Main features
1Fully automatic electric heating wire ignition (from designated time to automatic fire extinguishing);
2. Automatic timing and positioning of burner;
3. The ignition time can be set arbitrarily from 0 to 99.99 seconds, and the continuation time and flame retardant time are automatically recorded and displayed digitally;
4. The flame height can be adjusted and a flame temperature measurement device can be configured; (Various standard ignition heads can be provided according to customer requirements)
5. Automatic "push-pull" sample rack fixing device; (Using microcomputer control to achieve automatic integration)
6. Equipped with a highly sensitive combustible gas leakage alarm device. (Automatic gas cut-off upon discovery of gas leakage, alarm warning)