Product Overview
SenpuP200Portable gas chromatograph with high integration; Easy and portable; Accurate measurement; Features such as easy operation. Compliant with national standards
HJ 1012-2018 《Environmental air and exhaust gasesTechnical requirements and detection methods for portable monitoring instruments for total hydrocarbons, methane, and non methane total hydrocarbons How to translate
HJ38-2017Determination of Total Hydrocarbons, Methane, and Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources by Gas Chromatography
Working principle: According to the preprocessing method of Chinese national standards, the product first collects the sample gas to be tested and enters the portable gas chromatograph for quantitative analysis,
By switching the valve into the chromatographic column for separation, total hydrocarbons, methane, or characteristic factors sequentially reach the hydrogen flame ionization detector(FID)Detect and measure the concentrations of multiple components separately. Finally, the accurate value is calculated by the built-in processorTotal hydrocarbons, methane, non methane total hydrocarbons, and characteristic factor values.107 Product Features
■Specialized for miniaturizationFIDDetector, meeting the requirements
Dynamic linear range, supporting automatic ignition, automatic judgment, and automatic shutdown protection■
Integrate the traditional methane non methane total hydrocarbon online monitoring system into the same portable chassis, including a displayFID
Detector, switching valve, chromatographic column, electronic flow controller, battery, gas cylinder, etc■No need to connect to the mains or external gas lines on site, just one click to start up and measure the results■To ensure stable use of the instrument, the main unit and the heat tracing pipeline are powered by independent portable power sources
■Fully automatic electronic flow modules are required for gas circuits such as carrier gas, hydrogen gas, and combustion assisting gas(EPC)Control. The precision of carrier gas pressure control has reached
0.001psi■The analyzer adopts a color touch screen, which can display the test concentration, test spectrum, and instrument parameter status. The analytical instrument can be connected to a mobile handheld terminal through a stable wireless connection, supporting functions on the handheld terminalApp120Perform control■200Full process high-temperature heat tracing: from sampling toFID
The detector adopts a full process approach
|
℃ |
to℃ |
|
High temperature heat tracing effectively solves the problem of condensation loss of samples in high-temperature and high humidity gas environments, providing more accurate test results |
Main parameters |
|
function |
Analyze methane; Total hydrocarbons; Non methane total hydrocarbons; Benzene derivatives, etcV O C |
|
s |
size410 mm ( L ) x 280107 mm ( W ) x 235 mm ( H ) |
|
host weight |
≤9K g |
|
monitor |
FID |
|
Detector; satisfy |
Dynamic linear range |
|
Detection Principle |
0GC - FIDChromatographic column separationFlow control accuracy |
|
0.001 psi |
analysis cycleNMHC:30smeasurement range |
|
~5 |
0000ppm; AdjustableMinimum detection limit |
|
≤ |
0.03mg/m³ |
|
repetitiveness |
RSD |
|
≤ |
0.5%accuracy |
|
≤ Range ± |
1 %6control panel |
|
Portable high-definition industrial tablet |
communicationGPSPositioning, wireless printing, data uploading, remote control200power supply |
|
Built in power supply, with a battery life greater than |
200hourprobe temperature |
|
Heat tracing temperature |
-15room temperature50~ |
|
℃ adjustable |
Valve box temperature |
℃
|
Max . |
ambient temperature |
℃ ~ |
℃ |
|
1 |
working environment |
10 - 90 % R H |
1 |
|
2 |
Main configuration of the instrument |
ITEM |
1 |
|
3 |
CAT NO. |
DESCRIPTION |
1 |
|
4 |
QTY |
P200Portable chassis for gas chromatograph host |
1 |
|
5 |
detector |
Hydrogen flame ionization detector |
1 |
|
6 |
Sampling gunEquipped with a filtered heat tracing sampling gunsampling pump |
KNF |
1 |
|
7 |
Micro sampling pump |
Flow path control |
1 |
|
8 |
Fully electronic flow control |
chromatographic column |
1 |
|
9 |
/ |
Column box |
1 |