SW-CJ-1C series double single-sided, horizontal air supply ultra clean workbench Purification workbench Clean workbench Ultra clean table Purification table Clean table bioclean bench
SW-CJ-1C series double single-sided, horizontal air supply ultra clean workbench Purification workbench Clean workbench Ultra clean table Purification
Product details

HS-1300-UDesktop purification workbench is a local purification unit used in the fields of medicine, health, biotechnology, scientific experiments, etc. for sterile and dust-free clean environments.

SW-CJ-1Cu/SW-CJ-1C/SW-CJ-2GPurification workbench is a local purification unit used in the fields of medicine and health, biotechnology, scientific experiments, etc. for sterile and dust-free clean environments.

technical parameter

model

HS-1300-UDouble purification workbench (horizontal air supply/wide workbench) Air supply method: horizontal air supply

SW-CJ-1CUTwo person single-sided purification workbench (horizontal air supply) SW-CJ-1CU Suitable number of people: Two person single-sided

Cleanliness

100Grade @ ≥ 0.5 μ m (Federal 209E)

100Grade @ ≥ 0.5 μ m dust particle size,

≤ 3.5 White US Federal 209E

cfu

≤ 0.5 pieces per dish Time (¢ 90 mm culture dish)

≤ 0.5 per dish per hour * (in a 90mm culture dish)

Average wind speed

0.25m~0.45/m/s(Fast and slow dual speed

0.25m~0.45/m/s(Fast and slow dual speed

Vibration/Half Peak Value

≤ 0.5 μ m (X Y Z direction)

≤ 0.5 μ m x y z direction

Noise

62dB(A)

≤62dBA

illumination

≥300Lx

≥300Lx

Power Supply

AC/50HZ/220V

220V/50Hz/800w

weight

350kg

<400kg

Specification and quantity of high-efficiency filters

1135×600×50×①

1675×600×50×①

Specification and quantity of fluorescent/ultraviolet lamps

30W×①/30W×①

30W/30W

External dimensions

1300×760×1800mm

1800×730×1450mm

Size of workspace

1030×550×620mm

1770×500×600mm

model

SW-CJ-1CDouble person single-sided purification workbench/ultra clean table (horizontal air supply) (new type of quasi closed door) Suitable for: Double person single-sided

SW-CJ-2GDouble person single-sided horizontal air supply ultra clean table/purification workbench Applicable number of people: Double person single-sided

Cleanliness

100Grade @ ≥ 0.5 μ m (Federal 209E)

100Grade @ ≥ 0.5um (Federal 209E)

cfu

≤ 0.5 per dish · hour (¢ 90 mm culture plate)

≤ 0.5 pieces per dish Time (Φ 90mm culture dish)

Average wind speed

0.25m~0.45/m/s(Fast and slow dual speed

0.25~0.45m/s(Fast and slow dual speed

Vibration/Half Peak Value

≤ 0.5 μ m (X Y Z direction)

≤ 5 μ m (X.Y.Z direction)

Noise

≤62dB(A)

62dB(A)

illumination

≥300Lx

≥300Lx

Power Supply

ACSingle phase 220V/50HZ

AC/50HZ/220V/130W

weight

<400kg< span="">

<85kg< span="">

Specification and quantity of high-efficiency filters

1350×600×50×①

1135×600×50×①

Specification and quantity of fluorescent/ultraviolet lamps

30W×①/30W×①

30W×①/30W×①

External dimensions

1600×730×1600mm

1300×580×1600mm

Size of workspace

1360×600×620

1150×400×500mm

maintain

1According to the actual situation, regularly remove and clean the primary filter, with a cleaning cycle of generally 3-6 months. If not cleaned for a long time, dust accumulation will lead to insufficient air intake and reduce the cleaning effect.

2When the ideal cross-sectional wind speed cannot be achieved after normal replacement or cleaning of the primary air filter, the operating voltage of the fan should be adjusted to achieve the ideal uniform wind speed.

3Generally, when the operating voltage of the fan is adjusted to the highest point after 18 months of use and still cannot reach the ideal wind speed, it indicates that the high-efficiency air filter has accumulated too much dust (the filter holes on the filter material are basically blocked and need to be updated in a timely manner). The service life of a high-efficiency air filter is generally 18 months.

4When replacing the high-efficiency air filter, attention should be paid to the correct model, specifications, and dimensions (as configured by the original manufacturer), install the device according to the direction of the arrow, and ensure that the surrounding seal of the filter is sealed and there is no leakage.

General fault causes and troubleshooting methods

Fault phenomenon

reason

Exclusion method

The main power switch cannot be connected and automatically trips

1The fan is stuck, causing the motor to stall, or there is a short circuit in the circuit.

1Adjust the position of the fan shaft, or replace the impeller and bearings, and check if the circuit is intact.

2Check the insulation resistance of the circuit and components to the casing point by point according to the circuit diagram, and repair the insulation fault area.

Low wind speed

1. Excessive dust accumulation in the primary filter

2. High efficiency filter failure

1. Clean the primary filter.

2. Replace the high-efficiency filter.

The fan is not turning

1. The contactor is not working

2. The fuse core of the fan power supply has blown

1. Check if the contactor circuit is correct.

2. Replace the melt core.

The fluorescent light is not on

1. Lamp or relay damaged

2. The fuse of the lamp power supply has blown

1. Replace the light tube or relay.

2. Replace the melt core.

model

SW-CJ-1CDouble person single-sided purification workbench/ultra clean table (horizontal air supply) (new type of quasi closed door) Suitable for: Double person single-sided

SW-CJ-2GDouble person single-sided horizontal air supply ultra clean table/purification workbench Applicable number of people: Double person single-sided

Cleanliness

100Grade @ ≥ 0.5 μ m (Federal 209E)

100Grade @ ≥ 0.5um (Federal 209E)

cfu

≤ 0.5 per dish · hour (¢ 90 mm culture plate)

≤ 0.5 pieces per dish Time (Φ 90mm culture dish)

Average wind speed

0.25m~0.45/m/s(Fast and slow dual speed

0.25~0.45m/s(Fast and slow dual speed

Vibration/Half Peak Value

≤ 0.5 μ m (X Y Z direction)

≤ 5 μ m (X.Y.Z direction)

Noise

≤62dB(A)

62dB(A)

illumination

≥300Lx

≥300Lx

Power Supply

ACSingle phase 220V/50HZ

AC/50HZ/220V/130W

weight

<400kg< span="">

<85kg< span="">

Specification and quantity of high-efficiency filters

1350×600×50×①

1135×600×50×①

Specification and quantity of fluorescent/ultraviolet lamps

30W×①/30W×①

30W×①/30W×①

External dimensions

1600×730×1600mm

1300×580×1600mm

Size of workspace

1360×600×620

1150×400×500mm

HS-1300-UDouble purification workbench (horizontal air supply/wide workbench) Air supply method: horizontal air supply

SW-CJ-1CUTwo person single-sided purification workbench (horizontal air supply) SW-CJ-1CU Suitable number of people: Two person single-sided

SW-CJ-1CDouble person single-sided purification workbench/ultra clean table (horizontal air supply) (new type of quasi closed door) Suitable for: Double person single-sided

SW-CJ-2GDouble person single-sided horizontal air supply ultra clean table/purification workbench Applicable number of people: Double person single-sided