Beijing Speke Technology Co., Ltd
Home>Products>SPMK518 intelligent process calibrator
SPMK518 intelligent process calibrator
The SPMK518 intelligent process calibrator (multifunctional temperature and pressure process calibrator) adopts a 3.5-inch TFT color screen, Chinese d
Product details

product details

simple be situated between

SPMK518 intelligent process calibrator(Multi functional temperature and pressure process calibratoruse3.5cunTFTColor screen, Chinese display, mobile menu operation mode, built-inHARTHandheld controller, with powerful task management functions, meets the requirements of calibrating temperature, pressure and other process instruments in industrial sites and laboratories. It has a beautiful appearance, sturdy structure, compact and economical practicality, making it an ideal tool for calibrating, maintaining and repairing thermal instruments.

1618209483163542.jpg

main features

◆ It can measure voltage, current, resistance, frequency, pulse, switch (on/off), and can also use thermal resistors or thermocouples to measure temperature without interfering with each other;

◆ Can simulate13Thermocouples and11Measure and output thermal resistance, and provide cold end compensation;

◆ Provide isolation between measurement and output24VDCPower Supply;

◆ Support data storage function, support step or programming output methods;

◆ Built inHARTHandheld device, capable of achievingHARTManagement of basic information of type instruments, migration of measuring ranges, calibration and maintenance of functional equipment such as zero and full calibration;

◆ ConnectableSDPModular intelligent digital pressure calibrator;

◆ Provide commonly used tools such as thermal engineering encyclopedia, analog transmitter, user built thermal resistance library, temperature and pressure unit conversion, etc;

◆ Automatic cold end compensation technology: embedded cold end insulation module, quickly tracks temperature changes;

3.5Inch high resolutionTFTDisplay screen, Chinese language display, good human-computer interaction interface;

RS232The interface and open communication protocol facilitate remote networking for users and support online firmware upgrades.

Technical Parameter

Technical indicators for signal measurement(Environmental temperature)20±5,One year accuracy

Signal type

range

accuracy

resolution

electric current

(-3030)mA

±0.01%RD+0.005%F.S

0.1uA

voltage

(-3030)V

±0.01%RD+0.005%F.S

0.1mV

Millivolt voltage

(-7575)mV

±0.01%RD+0.005%F.S

0.1uV

resistance

3Line system

(0400)Ω
(04000)Ω

±0.02%RD+0.005%F.S

1mΩ
10mΩ

4Line system

(0400)Ω
(04000)Ω

±0.01%RD+0.005%F.S

1mΩ
10mΩ

frequency

(150000)Hz

±0.005%RD+0.002%F.S

1Hz

pulse

0999999

±1A pulse

1

Switch (on/off)

If the switch is equipped with inspection voltage, the voltage range is(324)V

thermocouple

KEJTNRSBCDGLU

thermal resistance

Pt1000(385)Pt500(385)Pt100(385)Pt100(3916)Pt100(3926)Pt10(385)Cu10(427)Cu50(428)Cu100(428)Ni120(672)Ni100(618)And custom types

pressure

Refer to this websitePressure Range Selection Table


Technical specifications for signal output(Environmental temperature)20±5℃, one-year accuracy)

Signal type

range

accuracy

resolution

electric current

022)mA

±0.02%RD+0.005%FS

0.1uA

voltage

012)V

±0.02%RD+0.005%FS

0.1mV

Millivolt voltage

(-10100)mV

±0.02%RD+0.005%FS

0.1uV

frequency

050000.0)Hz

±0.005%RD+0.002%FS

0.1Hz

pulse

0999999

±1A pulse

1

resistance

0400)Ω

±0.02%RD+0.005%FS

1mΩ

(4004000Ω

±0.03%RD+0.01%FS

10mΩ

24VDC

(24 ± 0.5) V maximum load capacity 50mA

thermocouple

KEJTNRSBCDGLU

thermal resistance

Pt1000(385)Pt500(385)Pt100(385)Pt100(3916)Pt100(3926)Pt10(385)Cu10(427)Cu50(428)Cu100(428)Ni120(672)Ni100(618)And custom types


Other indicators

1. Operating environment: ambient temperature (-10~50) ℃; Relative humidity<90% non condensing; Atmospheric pressure (86~106) KPa. a.
2. Storage environment: ambient temperature (-20~60) ℃; Storage humidity<90% non condensing.
3. Power supply: AC/DC power supply.

Note: In order to achieve better measurement and output results for the calibrator, it is recommended to use battery power.

Random accessories

packing list

name

model

unit

quantity

Multi functional process calibrator

SPMk518

tower

1

operation instructions

SPMK518User Manual

stem or root of plants

1

warranty card


share

1

certificate of conformity


share

1

The power adapter


individual

1

Pen line

0.5rice red

strip

1

Pen line

0.5rice black

strip

1

Pen line

1rice red

strip

3

Pen line

1rice black

strip

3

Alligator Clip

red

individual

3

Alligator Clip

black

individual

3

Compensation wire

Ktype

strip

1

Compensation wire

Etype

strip

1

The signal line

Seven Core

strip

1

Compensation wire

Utype

cover

1

packing list


share

1

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!