SF6Large scale recycling equipment(Winfoss-R1Liq)
Imported compressors from the United States and refrigeration systems from France for reliable and rapid liquefaction processing;American regenerative molecular drying filter effectively removes moisture and dust!

overview
SF6Large scale recycling equipment(Winfoss-R1Liq)correctWINFOSSA high-capacity, fully functional product designed by the company for the Chinese power industry and switch manufacturing enterprisesSF6Inflatable recycling vehicle. Capable of completing tasks for various purposesSF6Switchyard (including column switchesGISAll combination electrical appliances, switchgear, etcSF6All functions including gas filling, recovery, vacuuming, gas transfer, etc., including gas drying and filtration purification, including dielectric electrical equipment. The entire recycling vehicle includes imported high-speed compressors from the United States, two-stage direct coupled high-speed vacuum pumps, digital vacuum gauges, electromagnetic vacuum devices, drive devices, American molecular regeneration filter dryers, and electrical control components.
SF6Large scale recycling equipment(Winfoss-R1Liq)All gas pipelines are connected by copper pipelines, which have a longer service life and ensure reliable connection and excellent sealing performance between pipelines and joints.
characteristic
l Import of core components.
l Fully functional (recycling, vacuuming, filtering and drying, liquefaction, storage, gas refilling) with six major functions.
l The interface is concise and clear, and the operation is simple.
l Multiple safety valve settings to eliminate safety hazards.
l The vacuum pump is equipped with an anti oil return valve to prevent oil return at the inlet and outlet of the recovery device.
l Regenerative filters do not require regular replacement.

Function Introduction
l recycleAfter starting the high-precision vacuum pump and electromagnetic vacuum device and other electrical control components, the equipment is internally controlledSF6Gas extraction; It is divided into two types: gaseous recovery and liquid recovery.
l purificationEquipped with a complete set of purification devices for recyclingSF6The gas is purified through multiple drying, filtration and separation processes.
l Vacuum pumping:answerSF6The residual gas inside the switch body is passed through electromagnetic vacuum devices and driving devices, and the pressure differential is activated to makeSF6The vacuum state inside the switch body meets the standard requirements.
l inflateSupplement a certain amount of electrical equipment by starting the compressor and drive device inside the deviceSF6Gas, inflation capacity can be set according to equipment regulations.
l transferThe equipment can store the gas in the gas storage tank for a long time, and can also be used according to actual applicationsSF6Gas is transferred to the steel cylinder.
Technical Parameter
Device performance parameters
|
type type |
forced air cooling,Hand push mobile |
|
|
Ambient Temperature |
-20℃~45℃ |
|
|
recycle |
Initial pressure(MPa) |
0.8 |
|
Final pressure(KPa) |
≤53 |
|
|
1m3Time required for volume(h/m3) |
≤0.45 |
|
|
inflate |
Initial pressure(Pa) |
≤133 |
|
Final pressure(MPa) |
0.7 |
|
|
1m3Time required for volume(h/m3) |
≤0.2 |
|
|
Vacuum pumping from0.1MPato133PaIt takes time(h/m3) |
≤0.5 |
|
|
Extreme vacuum(Pa) |
≤10 |
|
|
Maintain vacuum from133Pawarp24Hourly increase value(Pa) |
≤400 |
|
|
year Leakage rate |
≤1% |
|
|
After recyclingSF6 |
moisture content(PPM/V) |
≤60 |
|
gas purity |
Oil content(PPM/G) |
≤10 |
|
store store hold implement |
Storage method |
liquid |
|
pressure(MPa) |
5.0 |
|
|
volume(L) |
400 |
|
|
Liquid storage capacity(kg) |
400 |
|
|
Vaporization method |
electrical heating |
|
|
Regeneration method of dry filter |
Vacuum heating activation regeneration |
|
|
power supply |
three-phase four-wire system 3Φ380V |
|
|
total power(kW) |
≤13 |
|
|
noisedB(A) |
≤75 |
|
|
Equipment weight(kg) |
≤950 |
|
Main component performance parameters
|
SF6compressor (Imported from the United States) |
form |
|
Oil piston,semi-closed |
|
displacement |
m3/h |
12.2 |
|
|
Maximum exhaust pressure |
MPa |
2.50 |
|
|
Allowable exhaust pressure |
MPa |
1.96 |
|
|
Minimum allowable suction pressure |
KPa |
53 |
|
|
Maximum allowable suction pressure |
MPa |
0.30 |
|
|
Maximum exhaust temperature |
℃ |
130 |
|
|
lubricant |
|
HD25Refrigerant Oil |
|
|
power |
kW |
3 |
|
|
power supply |
|
3Φ380V 50Hz |
|
|
vacuum pump |
pumping speed |
m3/h |
54 m3/h |
|
mbar |
Pa |
≤6*10-2 |
|
|
power |
kW |
4 |
|
|
power supply |
V |
3Φ380V 50Hz |
|
|
Refrigeration unit (Imported from France) |
standard rating |
Kcal/h |
4600 |
|
refrigerant |
|
R22 |
|
|
Maximum refrigerant charging amount |
kg |
2.5 |
|
|
lubricant |
|
HD25Refrigerant Oil |
|
|
power |
kW |
2.32 |
|
|
power supply |
|
3Φ380V 50Hz |
|
|
hold implement Domestic carbon steel |
Container category |
|
Class II |
|
Design pressure |
MPa |
5.0 |
|
|
Design Temperature |
℃ |
40 |
|
|
Storage container capacity |
L |
400 |
|
|
Storage container liquid storage capacity |
kg |
400 |
Standard configuration
l SF6Inflatable recycling device 1tower
l 5mHigh pressure conveying pipe (liquid conveying) 1root
l 5mLow pressure conveying pipe (gaseous conveying) 1root
l Conversion joint between recycling vehicle and switchgear 1only
l Steel cylinder connector 1only
l Dust and rain cover 1only
l Chinese instructions 1stem or root of plants
l User information such as factory inspection reports 1cover

Service guarantee
l Provide on-site training guidance and conduct on-site demonstration operations.
l Provide detailed Chinese manuals and user guidance.
l One year free warranty, lifetime spare parts support and maintenance.
l User profile information management, customer service department provides bi annual follow-up and tracking services.
l hotline365Answer user inquiries 24/7.